Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Solvothermal synthesis and magnetic properties of beta-Co2P nanorods
EN
Hexagonal high temperature phase beta-Co2P nanorods with a diameter of around 50 nm were synthesized via a mild solvothermal route. The reaction was carried out at 180 degrees C using cobalt chloride hexahydrate (CoCl2 center dot 6H(2)O) as Co source and yellow phosphorous as P source. The composition, structure as well as morphology were characterized by X-ray diffraction (XRD), X-ray photoemission spectroscopy (XPS) and transmission electron microscopy (TEM). The magnetic susceptibility curve indicates that the beta-Co2P nanorods show canted antiferromagnetic state, different from the paramagnetic state of orthorhombic low temperature phase beta-Co2P.
EN
Compound danshen preparations (CDPs) are used clinically for the treatment of cardiovascular and cerebrovascular diseases. By using the quantitative analysis of multi-components by single-marker (QAMS) method, sixteen compounds (danshensu, protocatechuic acid, protocatechuicaldehyde, caffeic acid, rosmarinic acid, lithospermic acid, notoginsenoside R1, salvianolic acid B, ginsenoside Rg1, ginsenoside Re, salvianolic acid A, salvianolic acid C, ginsenoside Rb1, ginsenoside Rd, cryptotanshinone, and tanshinone IIA were quantified on an ACQUITY ultraperformance liquid chromatography (UPLC) HSS T3 column (2.1 × 100 mm, 1.8 μm) with the mobile phase consisting of 0.1% formic acid aqueous solution (A) and acetonitrile (B) using a gradient elution at the flow rate of 0.30 mL/min in 30 min at 30°C, which was also validated by UPLC-diode array detection (DAD) and UPLC-electrospray ionization multistage/mass spectrometry (ESI-MS/MS) for assuring the feasibility and accuracy. Tested by robustness experiment under slightly changeable conditions, the stability of relative correction factor (RCF) proved to be stable, with RSDs below 5.69%, except for notoginsenoside R1 with relative standard deviation (RSD) 7.83%. This reliable and convenient QAMS method resolved the problem of standard substance insufficiency and improved the quality assessment of preparations consisting of complex compounds with different chemical structures, such as CDPs.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.