1
Content available remote Electrical Impedance Tomography in medical research
EN
This paper presents the applications of the Electrical Impedance Tomography (EIT) in medical imaging, selecting perfusion lung and female breast. In a study of breast to ensure a stable contact of electrodes indicated on the indirect method consisting in immersing the breast suitably measurements intermediate fluid container. Basic parameters are defined in medical imaging of impedance tomography method. The preferred method solutions of the inverse problem are linear algorithms based on finite element method approximating of the tested objects. The conductivity values in different regions are determined by the finite element method.
PL
W pracy przedstawiono zastosowania tomografii impedancyjnej w badaniach medycznych wybierając obrazowanie perfuzji płuc oraz badanie piersi kobiet. W badaniach piersi dla zapewnienia stabilnego kontaktu elektrod wskazano na metodę pośrednią polegającą na zanurzeniu piersi w odpowiednio opomiarowanym pojemniku z płynem pośrednim. Preferowaną metodą rozwiązania zagadnienia odwrotnego są algorytmy liniowe oparte na metodzie elementów skończonych przy aproksymacji badanych obiektów. Określono podstawowe parametry w obrazowaniach medycznych metodą tomografii impedancyjnej.
EN
Low-frequency magnetic therapy is already well established treatment of the vast range of diseases. The impact of low frequency magnetic field on human's and animals' bodies is the subject to research in many universities and medical centers. A portable microprocessor device "KTM" used in Pulsed Magnetic Field therapy has been developed at the Department of Measurement and Diagnostic Systems at the Electrotechnical Institute. Due to the device potential to use it for home therapy treatment there are new capabilities brought out e.g., increased accessibility, prolonged sessions, limited therapy costs, remote patient-doctor communication system. Magnetotherapy treatment can be an online monitored and controlled process. The device can be specified by low manufacturing and exploitation costs. Along with the "KTM" the specialized software for controlling several KTM devices from doctor's office has been created.
PL
Terapia wolnozmiennym polem magnetycznym jest uznaną metodą stosowaną przy leczeniu wielu schorzeń. Oddziaływanie pól na organizmy żywe oraz stosowanie wyspecjalizowanych urządzeń do wytwarzania tych pól jest przedmiotem badań w kilku ośrodkach medycznych i technicznych. W Zakładzie Systemów Pomiarowo-Diagnostycznych Instytutu Elektrotechniki opracowano mikroprocesorowe przenośne urządzenie „KTM”, do stosowania terapii impulsowym polem magnetycznym. Dzięki możliwości stosowania programowalnego urządzenia w domu pacjenta przez całą dobę uzyskuje się nowe możliwości terapeutyczne związane z szerszą dostępnością, wydłużeniem sesji, zmniejszeniem kosztu terapii, zdalną komunikacją lekarza z pacjentem. Proces magnetoterapii może być zdalnie monitorowany i modyfikowany przez Internet. Urządzenie charakteryzuje się stosunkowo niskim kosztem wytwarzania i eksploatacji. Wraz z urządzeniem opracowano instalowany w gabinecie lekarza system informatyczny, który może obsługiwać kilkadziesiąt przenośnych urządzeń.
3
Content available remote Badanie perfuzji płuc metodą tomografii impedancyjnej
PL
W pracy przedstawiono zastosowania tomografii impedancyjnej w badaniach przewietrzania klatki piersiowej. Określono podstawowe parametry obrazów medycznych uzyskiwanych metodą tomografii impedancyjnej. Podano preferowane metody rozwiązania zagadnienia odwrotnego oparte o algorytmy liniowe wykorzystujące aproksymację badanych obiektów przy zastosowaniu metody elementów skończonych. Zagadnienie odwrotne rozwiązano poprzez wielokrotną analizę zagadnienia prostego oraz minimalizację błędu rozkładu potencjałów na brzegu obszaru w stosunku do wektora danych pomiarowych – podano rekonstrukcję obrazu płuc dla danych uzyskanych w drodze eksperymentu.
EN
The paper presents the application of the EIT in the clinical chest ventilation tests. It presents the fundamental parameters of the medical images obtained using the EIT. The preferred methods are to solve the inverse problem based on linear algorithms using the approximation of the studied objects with the finite element method. The inverse problem has been solved by a multiple analysis of the simple problem and by minimizing the false distribution of the potentials at the edge of the area in relation to the vector of the measured data - the reconstructed lung image is given for the data obtained through the experiment.
PL
Terapia wolnozmiennym polem magnetycznym jest uznaną metodą stosowaną przy leczeniu wielu schorzeń. Oddzia-ływanie pól na organizmy żywe oraz stosowanie wyspecjalizowanych urządzeń do wytwarzania tych pól jest przedmiotem badań w kilku ośrodkach medycznych i technicznych w kraju i na świecie. W Zakładzie Systemów Pomiarowo-Diagnostycznych Instytutu Elektrotechniki opracowano mikroprocesorowe przenośne urządzenie "KTM" stosowane w terapii impulsowym polem magnetycznym. Dzięki programowalnym funkcjom urządzenie to może być stosowane w domu pacjenta przez całą dobę, przez co uzyskuje się nowe możliwości terapeutyczne związane z szerszą dostępnością, wydłużeniem sesji, zmniejszeniem kosztu terapii, zdalną komunikacją lekarza z pacjentem. Urządzenie charakteryzuje się stosunkowo niskim kosztem wytwarzania i eksploatacji. Wraz z urządzeniem opracowano instalowany w gabinecie lekarza system informatyczny, który może obsługiwać kilkadziesiąt przenośnych urządzeń.
EN
Low-frequency magnetic therapy is already well established treatment of the vast range of diseases. The impact of low frequency magnetic field on human's and animals' bodies is the subject to research. In many universities and medical centers. A portable microprocessor device "KTM" used in Pulsed Magnetic Field therapy was developed In the Department of Measurement and Diagnostic Systems at the Electrotechnical Institute. Due to the device potential to use it for home therapy treatment there are new capabilities brought out e.g., increased accessibility, prolonged sessions, limited therapy costs, remote patient-doctor communication system. The device can be specified by low manufacturing and exploitation costs. Along with the "KTM" the specialized software for controlling several KTM devices from doctor's office was created.
PL
Rozwój infrastruktury ładowania pojazdów z napędem elektrycznym jest jednym z podstawowych czynników umożliwiających wprowadzenie do sprzedaży oraz użytkowania samochodów elektrycznych. Instytut Elektrotechniki od kilku lat prowadzi badania w zakresie budowy tego typu infrastruktury. W artykule przedstawiono koncepcję mikrosieci inteligentnej, której podstawowa funkcją jest zapewnienie ładowania pojazdów w energię elektryczną. Pokazano jedno z możliwych rozwiązań systemów ładowania pojazdów elektrycznych z zastosowaniem alternatywnych źródeł energii, przede wszystkim źródeł odnawialnych. Koniecznym elementem takich systemów są wewnętrzne zasobniki energii. Przedmiotem badań są Inteligentne Systemy Ładowania pojazdów, reagujące na bieżącą sytuację obciążenia stacji ładowania, porę doby, stany wewnętrzne, takie jak stopień naładowania wewnętrznych zasobników energii, stan sieci elektroenergetycznej. Opisano stacje standardowego i szybkiego ładowania o standardzie CHADEMO zbudowaną w Instytucie Elektrotechniki. Przedstawiono jej budowę oraz sposób komunikowania z pojazdem elektrycznym.
EN
The electric cart charging system development is a necessary condition to boost demand for electric vehicles. For several years the Electrotechnical Institute has performed research in the area of developing electric car infrastructure. The concept of smart microgrid that supports electric vehicle powering has been presented. One of the possible solutions has been shown; i.e. charging system incorporating renewable energy sources that requires internal energy storage circuit. The performed research aims at Smart Charging Systems adaptable to the changing conditions of terminal load that varies over time, state of charge and electrical grid load profile. The article describes conventional and CHADEMO quick charging stations, developed at Electrotechnical Institute. Their physical and functional structures have been shown.
9
Content available remote Układ elektroencefalografu przenośnego do lokalizacji aktywności elektrycznej
PL
W pracy przedstawiono zbudowany przenośny wielopunktowy układ pomiarowy w oparciu o projekt OpenEEG z zastosowaniem do elektroencefalografii. Do budowy wykorzystano przetworniki analogowo-cyfrowe o rozdzielczości 0,5 uV. Wykonano pomiary aktywności obiektu o kształcie odpowiadającym rzeczywistej głowie człowieka dokonując następnie lokalizacji źródła.
EN
The portable multichanel measuring system which was build basing on the project OpenEEG was presented. This system was used to electroencephalography. To construction of this system the analog to digital converter was used with 0,5 uV resolution.
10
EN
The functional structure of the impedance tomography data acquisition system for measuring distribution of moisture in brick's walls is presented. The measuring system is equipped with current and voltage electrodes of a special design adapted for different construction materials, with an automatic switch of measuring channels and with an analog-to-digital converter. The image is obtained by numerical processing the measurements of potentials at the surface of the object by wit an aid of Boundary Element Method.
PL
W artykule przedstawiono strukturę funkcjonalną systemu gromadzenia danych tomografu impedancyjnego, stosowanego do wyznaczania zawilgocenia ceglanych murów. System pomiarowy wyposażony został w: elektrody prądowe i napięciowe specjalnie zaprojektowane do badania zawilgocenia muru, układ automatycznych przełączników napięcia pobudzającego i kanałów pomiarowych oraz przekształtnika analogowo cyfrowego. Obraz zawilgocenia otrzymuje się rozwiązując zagadnienie odwrotne za pomocą Metody Elementów Brzegowych.
PL
W artykule przedstawiono budowę tomografów impedancyjnych bazujących na wielokanałowych układach pomiarowych. Zostały sprecyzowane wymagania stawiane tym układom pomiarowym, oraz opisano wybrane sposoby pozyskiwania informacji i pobudzenia badanych obiektów. Pokazano występujące problemy przy budowie wielokanałowych układów pomiarowych oraz metody ich eliminacji. Zaprezentowane zostały układy tomografów impedancyjnych, zbudowanych w Instytucie Elektrotechniki Teoretycznej i Systemów Informacyjno Pomiarowych Politechniki Warszawskiej oraz Instytucie Elektrotechniki w ramach grantu Ministerstwa Nauki i Informatyzacji (nr 4 T07E 045 29) "Nowa tomograficzna metoda oceny stopnia zawilgocenia budynków", koordynowanego przez Instytut Budownictwa Politechniki Wrocławskiej. Na koniec przedstawione zostały wyniki uzyskane w trakcie badań nad tomografią impedancyjną w wyżej wymienionych ośrodkach.
EN
Two multichannel measuring setups applied to impedance tomography were presented in this paper. First of them is based on Agilent hardware and the second one is based on Advantech devices. The first tomograph takes advantage of Data Acquisition and Switch Unit Agilent 34970A. Advantech adapter card with A/C and C/A converter is used in the second tomograph. Mechanical structure and possible applications of these tomographs were presented too.
EN
Boundary Element Method for simulation of spatially heterogeneous objects of electroencephalography is presented in this paper. The four layer spherical model (representing skin, skull, CSF layer and brain) of the real head approximated with isoparametric six nodes triangles was considered. Forward problem for active source localization was presented in this paper.
PL
W artykule przedstawiono lokalizację aktywności elektrycznej w przestrzennych obiektach wielowarstwowych. Do budowy numerycznego obiektu zastosowano metodę elementów brzegowych. Uproszczony. Uproszczoną czterowarstwową głowę zawierającą modele skóry, czaszki, płynów mózgowo rdzeniowych (CSF) oraz mózgu aproksymowano sześciowęzłowymi trójkątami isoparametrycznymi. Przedstawiono sposób formułowania równań oraz metodę rozwiązania zadania prostego oraz możliwość przyspieszenia obliczeń poprzez zastosowanie transformaty falkowej. W artykule pokazano wpływ stosunku sygnału do szumu (SNR) na dokładność rozwiązania zadania odwrotnego.
EN
Conductivity measurement techniques in multielectrode systems is presented in this paper. Presented techniques were tested during wall humidity measurements in a laboratory on a wall model, made of bricks and masonry mortar. Contact impedance between electrodes and wall was analyzed and measured. Electrodes fastening method was elaborated. Electrical impedance tomograph based on Advantech cards was built and programmed.
14
Content available remote System wieloczęstotliwościowej tomografii impedancyjnej
PL
W referacie przedstawiono system pomiarowy tomografi i impedancyjnej, w którym zastosowano metodę wieloczęstotliwościową testowania obiektów. Metoda jest szczególnie przydatna w badaniach nieniszczących do wykrywania uszkodzeń korozyjnych, zmian spowodowanych zawilgoceniem, pęknięć i wad materiałowych.
EN
An impedance tomography measuring system using a multi-frequency structure testing method has been presented in the paper. The method is particularly useful in nondestructive testing for detecting corrosion or moisture damage as well as cracking and material defects.
PL
Przy badaniach wykorzystujących pomiary pola elektrycznego lub magnetycznego, zjawiska zachodzące w obiektach opisuje się równaniami Maxwella, wiążącymi parametry materiałowe jak: konduktywność elektryczną, przenikalność elektryczną i magnetyczną z potencjałem. Analizując badany obszar niejednorodny metodą elementów brzegowych uzyskuje się macierze blokowe o dużym wypełnieniu. Rozwiązanie takich równań macierzowych jest bardzo czasochłonne i wymaga zastosowania komputerów o dużej mocy obliczeniowej. Dla usprawnienia obliczeń numerycznych, w przedstawionej pracy zastosowano dyskretną transformację falkową ograniczającą wypełnienie macierzy.
EN
Maxwell equation was used to describe the physical phenomenon in measurement of electrical and magnetic fields. This equation was used to connecting potential with electric and magnetic permeability. Block and asymmetric matrix was given after boundary element method was used to describe the testing object. Discrete wavelet transformation was used to simplify numerical analyses. After used the discrete wavelet transformation the sparse matrix was received.
EN
Boundary Element Method for simulation of spatially homogeneous objects of electroencephalography and tomography is presented in this paper. The four layer spherical model (representing skin, skull, CSF layer and brain) of the real head approximated with isoparametric six nodes triangles was considered. For different kinds of boundary conditions formulation of the algebraic system of equations was explained in details.
17
EN
The paper presents an analytical solution of the clear region immersed in the highly scattering one. In the clear region diffusion equation is not valied, so the problem is solved with the aid of non-local boundary conditions, connecting highly scattering regions. This problem is very important in Optical Tomography as it is a numerical model of the thin CSF layer in the human brain. The analytical solution is an excellent benchmark problem so we can compare the numerical solution like FEM or BEM with the analytical one presented in this paper.
PL
Praca prezentuje analizę przypadku, gdy występuje podobszar przezroczysty, w którym nie obowiązuje równanie dyfuzji, zgodnie z którym, światło jest rozprzestrzeniane w środowiskach silnie rozpraszających (aproksymacja równania Boltzmana). W tym przypadku obszary rozdzielone taką warstwą (na przykład cienka warstwa płynu rdzeniowo-mózgowego CSF), są analizowane za pomocą tzw. nielokalnych warunków brzegowych, W pracy przedstawiono dwuwymiarowy przykład, rozpatrzono dwa przypadki takich warunków brzegowych i podano rozwiązanie dokładne, które może być pomocne przy weryfikacji symulacji numerycznej przypadków bardziej złożonych.
19
EN
In this paper a fully automated system for tomographic investigations was presented. System consists of the Impedance Tomograph and 2D and 3D scanner. A detailed description of the system as well as some of the images for 2D space were provided. To produce the 2D images the Bell Functions algorithm was adopted. For 3D space a huge data base has been created and some examples were shown to prove that such a system is able to provide high quality measurements. Using this data base Artificial Neural Network will be trained to create a 3D images.
20
Content available remote Model funkcjonalny tomografu impedancyjnego i badania eksperymentalne
PL
W pracy przedstawiono funkcjonalny model tomografu impedancyjnego. Dokonano opisu różnych wanien pomiarowych stanowiących eksperymentalne fantomy. Na podstawie wybranych wyników doświadczalnych przedstawiono konstrukcje obrazów badanych obiektów organicznych i nieorganiczonych. Opisano różne metody zbierania danych pomiarowych amplitudy sygnału oraz kąta przesunięcia fazowego dla badanych obiektów w przestrzeni 2D i 3D.
EN
The work presents functional model of impedance tomography. It includes description of different measuring bathtub, presenting experimental phantom. It presents the way of constructions of images of researched objects (organic and inorganic) base of chosen experimental results. Different methods of collecting the measurement data (amplitude and phase) for the investigated objects in two and three dimensional area.