Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
The combined effect of ozonation and catalysts on the oxidation of aqueous solutions of formaldehyde was investigated. The catalysts tested were oxides of transition metals: NiO, CuO, TiO2, WO3, CoO2, V2O5, MnO2 and MoO3. Of all the catalysts tested only MnO2 and MoO3 showed catalytic activity. The effects of a catalyst dose, pH of the medium and the ratio of the catalysts on the effectiveness of the process were examined. It was observed that catalytic ozonation increased the yield of the oxidation process at both working acid and alkaline reactions. The efficiency of catalytic ozonation increased with an increase in the dose of the catalyst. At pH 10 the results obtained showed that an increase in the ratio of MnO2 to MoO3 resulted in an increase in the process effectiveness. The effectiveness of catalytic ozonation of formaldehyde was compared with the effectiveness of ozonation alone under the same operating conditions. It was found that at pH 10 the effect of the catalyst on the degree of conversion of formaldehyde led to an increase in the degree of conversion from 28% to 88% at the end of the process. At pH 3.5 an increase in the degree of conversion at the end of the process ranged from 58% to 85%. A comparison of the COD reduction for catalytic ozonation and ozonation alone under the same operating conditions suggests that catalytic ozonation is a more effective method for formaldehyde removal from its aqueous solutions.
PL
Zbadano łączny wpływ ozonowania i katalizatorów na proces utleniania wodnych roztworów formaldehydu. Testowanymi katalizatorami były tlenki metali przejściowych: NiO, CuO, TiO2, WO3, CoO2, V2O5, MnO2 i MoO3. Z przebadanych katalizatorów tylko MnO2 i MoO3 wykazały aktywność katali-tyczną. Przeanalizowano wpływ dawki, pH roztworów oraz proporcji katalizatorów na efektywność procesu. Zaobserwowano, że katalityczne ozonowanie zwiększa skuteczność utleniania zarówno w środowisku kwaśnym, jak i alkalicznym. Stwierdzono, że skuteczność katalitycznego ozonowania zwiększa się wraz ze wzrostem dawki katalizatora. Badania wykazały, że przy pH 10 zwiększenie stosunku MnO2 do MoO3 powoduje zwiększenie efektywności procesu. Porównano efektywność katalitycznego ozonowania formaldehydu z efektywnością ozonowania w tych samych warunkach. Stwierdzono, że przy pH 10 katalizator powoduje zwiększenie stopnia konwersji formaldehydu z 28% do 88%, a przy pH 3,5 - z 58% do 85%. Porównanie stopnia obniżenia ChZT wskazuje, że ozonowanie katalityczne jest bardziej skuteczną metodą usuwania formaldehydu z wodnych roztworów niż ozonowanie.
EN
Oxidation of model aqueous solutions of formaldehyde, which is a pollutant contained in numerous industrial wastewaters, was studied. The stringent legal requirements for the content of this toxic substance in wastewater require an appropriate method for its degradation. Oxidation with ozone combined with hydrogen peroxide, which is a more powerful method for degradation, has been studied. The influence of pH of the medium and temperature was investigated. It has been found that the effectiveness of oxidation estimated by the degree of conversion a [%] in the presence of hydrogen peroxide is higher compared to ozonation alone. For pH 3.5 and T = 293 K the degree of conversion at the end of the process in the presence of hydrogen peroxide increases to 99% compared to 58% for ozonation alone. The effectiveness of oxidation was observed to depend on hydrogen peroxide concentration and increased with its concentration. It has been proved that the oxidation process runs through formic acid as byproduct, which is identified spectrophotometrically.
PL
Zbadano proces utleniania modelowych roztworów formaldehydu w wodzie. Formaldehyd jest zanieczyszczeniem występującym w ściekach przemysłowych. Ze względu na surowe normy prawne, ustalające dopuszczalne stężenia tej toksycznej substancji w odprowadzanych ściekach, konieczne jest opracowanie skutecznej metody degradacji formaldehydu. Zbadano proces jego utleniania ozonem w połączeniu z nad-tlenkiem wodoru. Metoda ta daje lepsze efekty niż proces utleniania samym tylko ozonem. Określono wpływ pH roztworu i temperatury na skuteczność utleniania. Stwierdzono, że efektywność utleniania formaldehydu określana za pomocą współczynnika konwersji ? [%] jest większa w obecności nadtlenku wodoru w porównaniu ze skutecznością utleniania tylko ozonem. Stopień konwersji na końcu procesu dla pH roztworu 3,5 oraz w temperaturze 293 K w obecności nadtlenku wodoru wzrósł do 99%, podczas gdy dla samego ozonu wynosił 58%. Zaobserwowano, że skuteczność utleniania zależy od stężenia nadtlenku wodoru i zwiększa się wraz ze wzrostem stężenia tego utleniacza. Wykazano, że w procesie utleniania formaldehydu produktem ubocznym jest kwas mrówkowy identyfikowany metodą spektrofotometryczną.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.