Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This study reports the variation of tree-ring widths and annual variation of concentration of metals (Na, Mg, Fe, Ni, Cu, Zn, Pb) in pine growing nearby chemical factories. The conifers (Pinus silvestris L.) investigated in this study covered the time span from 1920s to 2010 AD. Tree-ring widths were measured, dated and rechecked using the COFECHA. Radial trace-element profiles were determined by Laser Ablation Inductively Coupled Plasma Mass Spectrometry. The combined usage of tree ring width and chemical composition of wood provides historic records of anthropogenic impact on the environment and allows identifying the behavior adaptation of trees to the pollution. Data of pine tree cores collected from the sites nearby chemical factories show increasing levels of pollution linked to the increasing of industrial activities in Poland and subsequent dust fallout around the site. This study evidences that tree rings can be used as archives of past environmental contamination.
EN
Two chemical treatments for lead-210 measurement were compared on the sub-surface samples of a core from an ombrotrophic bog from East Belgium. The classical procedure involves a concentrated acid extraction of polonium. However, this treatment represents substantial health risks together with unknowns regarding both the degree of cleanliness and the Po extraction rate, and most importantly, is rather time consuming. We developed here an improved procedure involving an ashing step prior to acid extraction. This allows substantial improvements such as: 1/ the use of a relatively small amount of acid compared to the classical procedure and 2/ the substantial reduction of a total sample digestion time. Measurements of 210Pb concentrations were conducted by alpha spectrometry. Results show a good agreement of unsupported 210Pb activity obtained for both procedures, although some unknowns remain concerning the adsorption of 210Po on the plastic test tube, the volatilization of a small amount of ash, or the absorption of alpha particle at the alpha source surface. This however should not affect the 210Pb measurement as all the samples are spiked prior to ashing (i.e. the recoveries are fully monitored). Through this study, we are suggesting researchers to follow this new procedure in order to increase safety, cleanliness, better recovery and substantial time gain.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.