EN
The distribution network of PT. Pertamina (Persero) Refinery unit 3 Plaju - Sungai Gerong uses an underground cable type of conductor, where most of the switchbreakers and relays at substation 14 Plaju are still analog. one of which is the ground fault relay (GFR) on feeder A incoming substation 15 on substation 14 Plaju, for a long time the relay has not been reset, causing a tendency to reduce the sensitivity level of the relay in securing the system when a fault occurs (short circuit). ), to overcome this, it is necessary to evaluate and reset the fault relay to ground. Evaluation is done by calculating the fault current of 3 phase, 2 phase, and 1 phase to ground to determine the magnitude of the fault current in the feeder A delivery line and compare it to determine the ideal ground fault relay (GFR) setting. Based on the calculation, ideally setting the ground fault relay (GFR) for incoming substation 15 breaker at substation 14 Plaju on feeder A side 12 kV forIsetprimary 32.244 Aand Isesecondary t is0.107 A with t (time) 0.298 s while on the feeder side 6.6 kV, namely the primary Iset of 25.795 A and the secondary Iset of 0.081 A with t (time) of 0.308 s.
PL
Sieć dystrybucyjna PT. Pertamina (Persero) Jednostka rafineryjna 3 Plaju - Sungai Gerong wykorzystuje przewód typu podziemnego kabla, w którym większość wyłączników i przekaźników w podstacji 14 Plaju jest nadal analogowa. jednym z nich jest przekaźnik ziemnozwarciowy (GFR) na linii zasilającej Podstacja przychodząca 15 na podstacji 14 Plaju, przez długi czas przekaźnik nie był resetowany, co powoduje tendencję do zmniejszania poziomu czułości przekaźnika w zabezpieczaniu systemu, gdy wystąpi usterka (zwarcie). ), aby temu zaradzić, konieczne jest oszacowanie i zresetowanie przekaźnika błędu do masy. Oceny dokonuje się poprzez obliczenie prądu zwarciowego 3-fazowego, 2-fazowego i 1- fazowego do ziemi w celu określenia wielkości prądu zwarciowego w linii zasilającej A i porównanie go w celu określenia idealnego ustawienia przekaźnika zwarcia doziemnego (GFR). W oparciu o obliczenia, najlepiej ustawić przekaźnik ziemnozwarciowy (GFR) dla przychodzącego wyłącznika podstacji 15 w podstacji 14 Plaju po stronie linii A 12 kV dla Isetprimary 32,244 Ai Isesecondary t jest 0,107 A z t (czas) 0,298 s po stronie linii 6,6 kV, czyli Iset pierwotny 25,795 A i Iset wtórny 0,081 A z t (czas) 0,308 s.
EN
A Heat Exchanger is a secondary process unit that is widely needed in the chemical process industry. This equipment is used to exchange heat between two types of fluids that have different temperatures. The existence of several physical events that change the characteristics of the process causes the stability of the system to be disturbed that necessitates to control the changes in the process parameters. PID controllers are actually conventional controllers which, due to their relatively good condition and easy operation, are still widely used. Many methods have been introduced to analyze PID control parameters, including the Rungge-Kutta method. However, the controlling operators in an industrial process, in order to get good control performance in every industrial process in the event of overshoot or oscillation, adjust the control parameters manually through the trial and error method. For this reason, we need a technique that is able to adapt to changes in process parameters that occur, and at the same time perform automatic re-tuning of controlling parameters. This paper describes a program designed to form an oscillation and reduction curve with a PID controller on a heat exchanger. The design of this program must at least be in accordance with the dynamics of the actual events in the field. the results of the oscillation curve reduction program design which are quite good are the one with the 'PI' controller type as compared to those with the 'P' and 'PID' controller types. The results of the one with the control type 'P' are not good because the process variable (process temperature) is not close to the set. o be used for operator training in industrial processes in the event of disturbances in the form of oscillations.
PL
Wymiennik ciepła jest drugorzędną jednostką procesową, która jest powszechnie potrzebna w przemyśle chemicznym. To urządzenie służy do wymiany ciepła między dwoma rodzajami płynów, które mają różne temperatury. Istnienie kilku zdarzeń fizycznych zmieniających charakterystykę procesu powoduje zaburzenie stabilności systemu, co wymusza kontrolowanie zmian parametrów procesu. Regulatory PID to właściwie regulatory konwencjonalne, które ze względu na stosunkowo dobry stan techniczny i łatwą obsługę nadal znajdują szerokie zastosowanie. Wprowadzono wiele metod analizy parametrów regulacji PID, w tym metodę Rungge-Kutty. Jednak operatorzy kontrolujący w procesie przemysłowym, w celu uzyskania dobrej wydajności sterowania w każdym procesie przemysłowym w przypadku przeregulowania lub oscylacji, dostosowują parametry sterowania ręcznie metodą prób i błędów. Z tego powodu potrzebujemy techniki, która jest w stanie dostosować się do zachodzących zmian parametrów procesu, a jednocześnie wykonać automatyczne przestrojenie parametrów sterujących. W artykule opisano program przeznaczony do tworzenia krzywej oscylacji i redukcji z regulatorem PID na wymienniku ciepła. Projekt tego programu musi być przynajmniej zgodny z dynamiką rzeczywistych wydarzeń w terenie. wyniki projektu programu redukcji krzywej oscylacji, które są dość dobre, to te z regulatorem typu „PI” w porównaniu z tymi z regulatorami typu „P” i „PID”. Wyniki tego ze sterowaniem typu „P” nie są dobre, ponieważ zmienna procesowa (temperatura procesu) nie jest zbliżona do zadanej. o być używany do szkolenia operatorów w procesach przemysłowych w przypadku zakłóceń w postaci oscylacji.