Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the results of the research on the influence of the adjuvant concentration on the size of the drops produced by the spray nozzles of agricultural sprayers. For the tests, adjuvant Normaton with the composition of total nitrogen, amide nitrogen (N-NH2) and phosphorus pentoxide (P2O5) was used. The adjuvant was added to the water taken from the municipal water supply system of the city of Lublin. The tests were carried out for three concentrations, i.e. 75%, 100%, and 125% of the adjuvant concentration recommended by the manufacturer, and water without the adjuvant. The surface tension of water with adjuvant was examined for each nozzle. Then, the size of the obtained droplets was measured for each adjuvant concentration. Two types of nozzles were used for spraying, standard nozzle AP 120-03 and 6MSC injector nozzle, both with the same nozzle flow rate, but with a different design. The size of the droplets produced was measured on a HELOSVARIO laser diffractometer by Sympatec. The droplet measurement was performed at a pressure of 3 bar. The nozzle was placed 50 cm above the diffractometer laser light line. The droplet size was measured in three places of the sprayed liquid, i.e. in the position of the nozzle axis, 30 and 60 cm from the nozzle axis. It was shown that the addition of the adjuvant influenced the number of droplets produced in the indicated droplet size classes.
PL
W pracy przedstawiono wyniki badań nad wpływem stężenia adiuwanta na wielkość kropel wytwarzanych przez rozpylacze rolnicze. Do badań użyto adiuwantu Normaton o składzie: azot całkowity, azot amidowy (N-NH2) i pięciotlenek fosforu (P2O5). Adiuwant dodawano do wody pobieranej z miejskiej sieci wodociągowej z Lublina. Badania przeprowadzono dla trzech stężeń, tj. 75%, 100% i 125% stężenia adiuwanta zalecanego przez producenta, oraz dla wody bez dodatku adiuwanta. Dla każdego stężenia adiuwanta badano napięcie powierzchniowe, a następnie mierzono wielkość uzyskanych kropel adiuwanta. Do opryskiwania użyto dwóch typów rozpylaczy: rozpylacza standardowego AP 120-03 i rozpylacza eżektorowego 6MSC - oba o takim samym natężeniu przepływu, ale o innej konstrukcji. Wielkość wytwarzanych kropel mierzono za pomocą dyfraktometru laserowego HELOS-VARIO firmy Sympatec. Pomiar kropel przeprowadzono pod ciśnieniem 3 barów. Rozpylacz umieszczano 50 cm nad linią światła lasera dyfraktometru. Wielkość kropel mierzono w trzech miejscach rozpylanej cieczy, tj. w na osi rozpylacza oraz w odległości 30 i 60 cm od osi rozpylacza. Wykazano, że dodatek adiuwanta wpływa na liczbę wytwarzanych kropel we wskazanych klasach wielkości kropel.
EN
The research material was prune plums (Prunus domestica L.), subjected to osmotic pre-treatment, with variable process time parameters and osmotic solution concentration. Plums thus fixed were frozen and stored for 6 months. At even (monthly) intervals, the product was defrosted by the vacuum-steam method, using the s-p-p chamber, until the thermocouple indicated a temperature of 4ºC in the sample's thermal center. In order to study the kinetics of phenomena occurring during the defrosting process, the chamber was equipped with a measuring system to enable measurement and recording of temperature changes in time in the geometric center of the sample, as well as the temperature on the sample surface. The conducted tests proved that the time of vacuumsteam defrosting of fruit depended on the amount of water contained in it. In plums dehydrated in 45-65% sucrose solutions, duration of the defrosting process was shortened already after three months of frozen storage. After 6 months of storage, defrosting of these fruits was twice as fast as that of control samples.
PL
Materiałem badawczym były śliwki odmiany Węgierka Zwykła (Prunus domestica L.). Owoce poddano wstępnej obróbce osmotycznej, przy zmiennych parametrach czasu procesu oraz stężenia roztworu osmotycznego. Tak utrwalone śliwki zostały zamrożone i przechowywane przez 6 miesięcy. W równych odstępach czasu (co miesiąc) produkt był rozmrażany metodą próżniowo-parową, z zastosowaniem komory s-p-p, do momentu wskazania przez termoparę temperatury 4ºC w centrum termicznym próbki. W celu zbadania kinetyki zachodzących zjawisk w czasie procesu rozmrażania, komora wyposażona była w układ pomiarowy, który umożliwił pomiar i rejestrację zmian w czasie temperatury w centrum geometrycznym próbki oraz temperatury na powierzchni próbki. Przeprowadzone badania dowiodły, że czas rozmrażania próżniowo-parowego owoców był zależny od ilości zawartej w nich wody. W śliwkach odwadnianych w roztworach sacharozy w zakresie stężeń 45-65% już od trzeciego miesiąca zamrażalniczego przechowywania nastąpiło skrócenie czasu procesu. Po 6 miesiącach przechowywania rozmrażanie tych owoców przebiegało 2-krotnie szybciej niż prób kontrolnych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.