Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In recent years, great emphasis has been placed on the introduction of energy-saving solutions to the construction sector. Building envelopes made of concrete with a specially selected composition give great opportunities in this regard. As part of a wide-ranging experiment, the authors undertook to diagnose how much thermal conductivity, volumetric specific heat and thermal diffusivity can be improved with an aerating admixture and different types of aggregates. Three groups of composites were tested: B1 – on stone aggregate, B2 – on expanded clay aggregate, B3 – on sintered fly ash aggregate. Each of the groups was divided into 4 formulations made without an aerating admixture and with its increasingly higher content of 0.8, 1.1, 1.4% in relation to the weight of cement. The thermal parameters were measured on the top (T) and bottom (B) surfaces of 36 rectangular samples (3 samples from each of the 12 mixtures) with the ISOMET 2104 apparatus. Diagnostic tests concerning the influence of measurement conditions were carried out on dry and water-saturated samples. It has been proven that for each composite and in both conditions, the values of thermal parameters determined on the lower surfaces will not correctly describe the properties of the real structure present in the main volume of the element. Only measurements carried out on surfaces with a structure corresponding to the interior of the element provide adequate data that can be used in decision-making processes and in numerical simulations to assess the real thermal qualities of building envelopes.
PL
W ostatnich latach kładzie się duży nacisk na wprowadzenie energooszczędnych rozwiązań do sektora budownictwa. Duże możliwości w tym względzie dają przegrody budowlane wykonane z betonów o specjalnie dobranym składzie. Autorki w ramach szeroko zakrojonego eksperymentu podjęły się zdiagnozowania, na ile można poprawić przewodność cieplną λ, objętościowe ciepło właściwe CV oraz dyfuzyjność termiczną za pomocą domieszki napowietrzającej oraz różnego rodzaju kruszyw. Badaniom poddano trzy grupy kompozytów: B1 – na kruszywie kamiennym, B2 – na kruszywie keramzytowym, B3 – na kruszywie popiołoporytowym. Równocześnie każda z grup została podzielona na 4 receptury wykonane bez domieszki napowietrzającej oraz z coraz to wyższą jej zawartością wynoszącą 0.8, 1.1, 1.4% w stosunku do masy cementu. Badania parametrów cieplnych zrealizowano techniką niestacjonarną wykorzystując aparat ISOMET 2104. Pomiary przeprowadzono na górnych i dolnych powierzchniach 36 próbek prostopadłościennych (po 3 próbki z każdej z 12 mieszanek), wykonując je na każdej z powierzchni dwukrotnie. Górne powierzchnie reprezentowały faktyczną strukturę występującą we wnętrzu każdego z badanych kompozytów. Dolne powierzchnie ukształtowane na styku z dnem formy odznaczały się na tyle zmienioną strukturą, że w bardzo istotny sposób zmieniały wartości sczytywanych na nich parametrów. Badania diagnostyczne, dotyczące wpływu warunków pomiarowych, przeprowadzono na próbkach suchych i nasyconych wodą. Udowodniono, że w przypadku każdego kompozytu i w każdych warunkach wilgotnościowych, wyznaczone na dolnych powierzchniach wartości parametrów cieplnych nie będą prawidłowo opisywać właściwości realnej struktury występującej w zasadniczej objętości tego elementu.
PL
W artykule przedstawiono wyniki badań podciągania kapilarnego, które przeprowadzono na próbkach betonu komórkowego czterech klas gęstości: 400, 500, 600 oraz 700 pochodzących z tej samej wytwórni. Największą dynamiką procesu podciągania kapilarnego charakteryzowały się próbki betonu komórkowego klasy gęstości 400. Relacje między średnimi wartościami współczynników sorpcji A wyglądały następująco: A400/A500 = 3,92/2,48 = 1,58; A400/A600 = 3,92/2,26 = 1,73; A400/A700 = 3,92/2,36 = 1,66.
EN
The article presents the results of research on the capillarity suction process, which were carried out on four density class of autoclaved aerated concrete specimens from the same manufacturer: 400, 500, 600 and 700. The highest dynamics of the process of capillarity suction was observed in autoclaved aerated concrete specimens of density class 400. Relationships concerning the resultant values of water sorption coefficients A were respectively: A400/A500 = 3,92/2,48 = 1,58; A400/A600 = 3,92/2,26 = 1,73; A400/A700 = 3,92/2,36 = 1,66.
PL
Artykuł prezentuje badania współczynników przewodzenia ciepła betonów komórkowych czterech klas gęstości 400, 500, 600 i 700, pochodzących z jednej wytwórni. W badaniach zasymulowano sytuację, w jakiej mogą znaleźć się ściany budynku narażone na działanie wody, np. powodziowej. Woda rozprzestrzenia się na grubości przegrody wykonanej z poszczególnych betonów w różnym tempie. W każdym przypadku dochodzi jednak do pogorszenia ich izolacyjności cieplnej. Celem przeprowadzonych prac badawczych była ocena skali tej zmienności. Eksperyment przeprowadzono na dwóch grupach próbek – suszonych i niesuszonych. Wykazano, że proces suszenia próbek może istotnie oddziaływać na uzyskiwane wyniki.
EN
The article presents the research of the thermal conductivity coefficients referring to autoclaved aerated concretes 400, 500, 600 and 700 density class, produced by one manufacturer. The research simulated a situation in which walls of a building can be exposed to the impact of water, e.g. flood water. Water penetrates walls made of different sorts of concrete at different speed. However, in each case, their thermal insulation worsens. The aim of the research conducted was to assess the scale of the changes. The experiment was performed on two groups of samples: the dried ones and the not dried ones. It was proved that the drying process of the samples can considerably influence the results obtained.
EN
The influence of the silica fume (SF) addition on the basic mechanical and thermal parameters of cement concrete was presented in this paper. Numerous studies show that the specific properties of silica fume allow producing concretes with increased strength and durability properties. However, the results of the authors' own studies demonstrated that under specific circumstances, the SF addition can negatively affect the strength of cement concrete. In this paper, the concretes made from two types of coarse aggregate, 4–8 mm fraction: reference ordinary gravel aggregate (Ref) and broken basalt aggregate (Bas) were tested. Comprehensive tests (microstructural, strength and thermal) were carried out on three formulas: the first one (Ref-0) did not contain any additives or admixtures. Silica fume and superplasticizer were used in the second formula (Ref-8), introduced in the amount of 8% and 0.75% of the cement’s weight, respectively. The third formula, based on basalt aggregate (Bas-8), also contained silica fume and a superplasticizer, dosed in the same amount as in the second formula. Porosimetric studies showed that the use of silica fume in the Ref-8 formula resulted in a decrease in the number of pores smaller than 0.15 μm in comparison to the Ref-0 reference concrete without the silica fume. On the other hand, numerous additional pores with diameters ranging from 0.05 to 300 μm were found in the Bas-8 concrete. In turn, optical porosimetry proved that the basalt-based concrete had numerous pores in the range above 70 μm, which were not observed in the case of the concretes with ordinary pebble aggregate. In the case of the normal concrete, the addition of silica fume resulted in an increase in the compressive strength. However, the basalt-based concrete, due to its much higher porosity, achieved significantly lower strength values. The results showed that the observed changes in porosity, caused by the presence of silica fume, resulted in lower values of thermal conductivity and specific heat of mature composites that it had been added to. This was particularly evident for the basalt-based concrete.
PL
Przeanalizowano wpływ domieszki napowietrzającej na tempo wnikania wody w głąb elementów betonowych. Opisano badania podciągania kapilarnego na próbkach nienapowietrzonych oraz napowietrzonych domieszką dozowaną w ilości 0,8; 1,1; 1,4% masy cementu. Wyznaczono współczynniki sorpcji kapilarnej, będące miarą odporności na penetrację wody poszczególnych kompozytów i ich potencjalnej trwałości.
EN
This study examined the extent to which the aeration admixture affects the rate of water penetration into concrete elements. Capillary rise was examined in unaerated samples and samples aerated with an admixture using the following proportions 0.8, 1.1, and 1.4% of cement weight. The coefficients of capillary sorption were determined, which are a measure of resistance to water penetration, and the potential durability of each composite material studied.
PL
Badano przewodność cieplną betonów bez domieszki i z domieszką napowietrzającą dozowaną w ilości 0; 0,8; 1,1; 1,4% masy cementu. Betony różniły się rodzajem zastosowanego kruszywa: kamiennego, keramzytowego i popiołoporytowego. Stwierdzono, że w celu poprawy właściwości cieplnych betonu, z którego ma być wykonana przegroda, należy zastosować odpowiednio dobrane kruszywo lekkie oraz dodatkowo wprowadzić domieszkę napowietrzającą w ilości zależnej od właściwości danej mieszanki.
EN
The research covers thermal conductivity of concretes without and with air-entraining admixture used in proportions: 0, 0.8, 1.1, and 1.4% of cement weight. The concretes differed in terms of the aggregate used: stone, expanded clay and sintered fly ash. It was concluded that, in order to improve the thermal properties of the concrete used for construction of the partition, the following needs to be applied: properly selected light aggregate and additional aeration admixture introduced according to particular features of a chosen mixture.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.