Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 23

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
This paper presents the concept of an autonomous measuring instrument powered by a locally accessible source of heat with a contact surface area of over a dozen or several dozen cm2 and a temperature higher or lower than the ambient temperature. The design and construction of the measuring device will be based on two modules developed and constructed in the course of previous work: a dedicated low-power thermoelectric generator and luminescent fiber-optic detector. The system can be additional equipped with a wireless transmission module. The studies show that, due to the power supply and photoluminescent measurement system with high stability of the operating point, this device will be capable of continuous operation without maintenance for many months.
PL
W artykule została przedstawiona koncepcja autonomicznego przyrządu pomiarowego zasilanego lokalnie dostępnym źródłem ciepła o powierzchni kontaktowej od kilkunastu do kilkudziesięciu centymetrów kwadratowych i temperaturze wyższej lub niższej od temperatury otoczenia o kilkanaście stopni Celsjusza. Opisano budowę i zasadę działania dwóch opracowanych w toku dotychczasowych prac modułów: dedykowanego generatora termoelektrycznego małej mocy oraz luminescencyjnego, światłowodowego detektora gazów. Przeprowadzone badania wskazują, że układ pomiarowy oparty na zaprezentowanej technologii będzie przez wiele miesięcy zdolny do ciągłego działania bez obsługi serwisowej.
EN
The spatial range of the present analysis spans the rural and urban communities of Lower Silesia region. The aim of the study was to determine the needs in terms of environmental protection and development, due to environmental resources and equipment in the communal infrastructure. The environmental aspect of spatial order was evaluated. It was assumed that the implementation of the spatial order in the aspect of the environment is done by means of developing that environment, and especially by the presence / absence of the biotic (natural) elements and the presence / absence of technical infrastructure (utilities), as well as the proper use thereof. Analyses were performed using the following indicators: the share of protected areas in the total area of the community, the share of green areas in the total area of the community, forestation rates, share of the population using sewage system in the general population of the community, number of domestic sewage treatment plants and number of septic tanks per 1000 inhabitants, as well as the total municipal waste per capita. Rural and urban communities were compared. The data was obtained from GUS (Central Statistical Office), the local data bank. The results allowed for ranking the communities included in the study according to a hierarchy, and grouping them in the terms of spatial order in the environmental aspect.
PL
Opracowaniem objęto gminy wiejskie i miejskie województwa dolnośląskiego. Celem pracy było określenie potrzeb ochrony i kształtowania środowiska ze względu na zasoby środowiskowe oraz wyposażenie w infrastrukturę komunalną badanych jednostek. Oceniano stan ładu przestrzennego w aspekcie środowiskowym. Przyjęto założenie, że realizacja ładu przestrzennego w aspekcie środowiskowych odbywa się poprzez kształtowanie środowiska, a zwłaszcza poprzez obecność/brak jego elementów ożywionych (przyrodniczych) oraz obecność/brak infrastruktury technicznej (komunalnej) oraz jej prawidłowe wykorzystanie. Analizy przeprowadzono korzystając z następujących wskaźników: udział powierzchni obszarów chronionych, lasów i terenów zieleni urządzonej w powierzchni gminy ogółem, udział osób korzystających z sieci kanalizacyjnej w ogólnej liczbie ludności, liczba oczyszczalni przydomowych i zbiorników bezodpływowych na mieszkańców, ilość odpadów komunalnych przypadających na mieszkańca. Gminy wiejskie porównano z gminami miejskimi. Dane pozyskano z Banku Danych Lokalnych (GUS). Uzyskane wyniki pozwoliły na hierarchizację badanych gmin oraz ich grupowanie pod względem poziomu ładu przestrzennego w aspekcie środowiskowym.
6
Content available Topiary - formy roślinne budujące przestrzeń
PL
Topiary są obecne w przestrzeni od wieków. Powstawały prawdopodobnie już w starożytnym Egipcie. Pojawiały się w każdej epoce. Stosowane są również współcześnie. W artykule podjęto próbę przedstawienia uniwersalnych możliwości zastosowania topiarów w przestrzeni. Zaprezentowano funkcje jakie mogą pełnić te formowane rośliny oraz dokonano podziału topiarów ze względu na ich formę.
EN
Topiaries have been present in our space for ages. They were probably created in ancient Egypt. They were used in every epoch and are used nowadays. In the article an attempt to present possibilities of using topiaries in our space was made. Different functions which these formed plants could perform were presented and a division of shape was made.
7
Content available remote Dynamic compaction of cohesive soils – theoretical aspects and modeling
EN
The principles of dynamic compaction of soils are presented in the paper, along with a short description of its usefulness for cohesive soils. The main topic of the article is the description of ways of modeling the phenomenon related to dynamic compaction. This is based on experimental data and on recently developed computer models using the Finite Element Method. Existing simplified ‘perfectly flexible plastic’ model is presented and used for computer modeling. The model does not capture the highly plastic and nonlinear behavior of cohesive soils under dynamic compaction. Additionally, a modified Cam-Clay constitutive model will be briefly described, which can address the above mentioned issues. Computer modeling method of the phenomenon will be discussed, together with a short description of the dynamic characteristics of the process.
PL
W artykule przedstawiono podstawy zagęszczania dynamicznego wraz z krótkim opisem jego stosowalności dla gruntów spoistych. Podstawowym tematem artykułu jest jednakże opis modelowania tego zjawiska. Jest on oparty na danych doświadczalnych oraz, ostatnio rozwiniętych, metodach opartych na Metodzie Elementów Skończonych. Przedstawiono podstawy modelu doskonale plastycznego (stosowanego w modelowaniu komputerowym). Model ten nie odzwierciedla jednak wysoce plastycznego i nieliniowego zachowania gruntów spoistych pod wpływem dynamicznego zagęszczania. Zmieniony model konstytutywny Cam-Clay został krótko opisany, może on do pewnego stopnia rozwiązać powyższe problemy. Zostaną przedstawione sposoby praktycznego modelowania zjawiska, a także podstawy komputerowego modelowania zjawiska, wraz z dyskusją dynamiki procesu.
PL
W gospodarce rynkowej odbiorcy wody zaczęli racjonalnie i oszczędnie korzystać z wody wodociągowej, a w przedsiębiorstwach wodociągowych zaistniał problem nadmiaru produkowanej wody. Rozwiązanie tego problemu ma istotny wpływ na poprawę efektywności prowadzenia działalności, a co za tym idzie ograniczenia kosztów eksploatacji systemów wodociągowych. W pracy wykonano analizy jednostkowych wskaźników zużycia wody w systemach zaopatrzenia w wodę w wybranych gminach powiatu płockiego oraz analizę struktury zużycia wody wodociągowej na różne cele. W analizie dokonano porównania obliczonych wskaźników zużycia wody na terenach wiejskich, z odpowiednimi wskaźnikami dotyczącymi miast różnej wielkości, a także ze wskaźnikami opracowanymi w „Wytycznych do programowania zapotrzebowania wody i ilości ścieków w miejskich jednostkach osadniczych”, które wydane zostały w 1978 r. i obowiązują do dziś. Wszystkie analizy zostały opracowane na podstawie badań ankietowych, przeprowadzonych we wszystkich gminach powiatu płockiego w roku 2008.
EN
In the market economy the customers have begun using the tap water reasonably and efficiently, and the water supply companies faced the problem of water produced in excess. In this work the analysis of unit indicators of water consumption in water distribution systems in selected communes of Płock County was conducted, as well as the analysis of water consumption structure for different purposes. In the analysis the comparison of calculated water consumption indicators in rural areas with appropriate indications regarding cities of various size is made, and with the indicators developed in “Guidelines for programming the water requirement and amount of sewage in urban settlements”, issued in 1978 and in force today. All analyses were developed on the basis of surveys conducted in all communes of Płock County in 2008.
9
Content available remote Johann Wolfgang von Goethe oraz jego wkład w rozwój górnictwa i geologii
PL
Johann Wolfgang von Goethe, wielki poeta niemiecki, był także badaczem, uczonym, mężem stanu oraz sprawnym ministrem. Wywarł wpływ na rozwój nauki i techniki, w tym górnictwa i geologii. W tej pracy zarysowano sylwetkę Goethego, opisano filozofię jego pracy, życia oraz badań, a także wkład w rozwój górnictwa i geologii.
EN
Johann Wolfgang von Goethe, a great German poet was also a knowledgeable researcher and scientists, influential statesmen as well as efficient manager. His accomplishments and inputs into development of science and techniques including mining and geologist have been presented. Elements of his curriculum vitae as well as his philosophy on work, life, and science have been outlined.
10
Content available remote Analiza strat wody w podsystemie dystrybucji wody w Płocku w latach 2002-2008
PL
Straty wody w systemach zaopatrzenia w wodę stanowią poważny problem dla każdego przedsiębiorstwa wodociągowego oraz wymuszają konieczność podejmowania działań ograniczających straty wody. W artykule przedstawiono analizę strat wody w podsystemie dystrybucji wody w Płocku w latach 2002-2008 ze szczególnym uwzględnieniem strat rzeczywistych. Scharakteryzowano podsystem dystrybucji wody w Płocku wraz z bilansami wody. Obliczono, korzystając z bilansów wody za lata 2002-2008, zarówno rejestrowane, jak i dopuszczalne jednostkowe wskaźniki strat wody oraz procentowe straty wody. Otrzymane wyniki porównano z wartościami zalecanymi w literaturze.
EN
The losses of water in water supply system are a serious problem for every water supplying company and a necessity of taking action reducing the losses of water. The following work presents the analysis of the losses of water in the water supply subsystem in Plock in years 2002-2008 taking the real losses into special consideration. The water-supply subsystem in Plock is described as well as the water balance. Both registered and acceptable unit water loss indexes are, using the water balances from years 2002–2008, calculated. Received results are compared with the recommended values from the literature.
12
Content available remote Ocena funkcjonowania podsystemu dystrybucji wody w Płońsku (woj. mazowieckie)
PL
Bardzo ważnym elementem analizy funkcjonowania systemu zaopatrzenia w wodę sq badania awaryjności podsystemu dystrybucji wody oraz określenie strat wody w sieci wodociągowej. Zagadnienia te mają zasadnicze znaczenie z punktu widzenia prawidłowej eksploatacji całego systemu, pozwalają na wnioskowanie o stanie technicznym przewodów i uzbrojenia, a także umożliwiają planowanie remontów głównych sieci wodociągowej. W pracy przedstawiono analizę awaryjności podsystemu dystrybucji wody w Płońsku (woj. mazowieckie) w latach 2003-2005. Przeanalizowano uszkodzenia mechaniczne, korozyjne i na złączach przewodów wodociągowych w aspekcie struktury materiałowej i wiekowej przewodów. Obliczono wskaźniki jednostkowej częstości uszkodzeń oraz jednostkowe wskaźniki strat wody dla rozpatrywanej sieci, co pozwoliło na stwierdzenie, że stan techniczny sieci poprawia się. Wskazuje to na podejmowanie czynności naprawczych, racjonalne planowanie remontów i sprawniejsze zarządzanie siecią.
EN
Very importanł element of analysis of water supply system operation is the examination of water distribution subsystem failure freąuency and the determination of water loss in water supply system. These matters are essential from the point of view of the whole system operation, they allow to draw the conclusion about the technical condition of conduits and reinforcement and they enable to plan the repairs of main water supply systems. In the thesis, the analysis of the water distribution subsystem failure freąuency in Płońsk (Mazovia) within the years 2003-2005 was presented. Mechanic damages, corrosion damages and the damages of water conduits joints were analized taking into account the materiał and age structure of the conduits. The index of unitary freauency of failure freąuency and water loss unit indexes for the examined system was calculated, which allowed to find that the technical condition of the system is improving. This indicates the undertaking of rapair actions, rational repair planning, and morę efficient system management.
EN
Alkali metals (Li, Na, K, Rb) and Ca were introduced to vanadia dispersed on magnesia: the catalysts obtained were characterized by XRD, XPS isopropanol decomposition (a probe of acido-basic properties) and tested in oxidative dehydrogenation of propane, ODH. No vanadia phase was observed by XRD, vanadium being most probably present in the samples as magnesium orthovanadate dispersed on the MgO surface. Low concentration of acidic and high of basic centres have been observed in the catalysts. Selectivity to propene does not exceed 40%, andCO2 is themain product of total oxidation. The presence of the additives leads to: a) decrease of the acidity and increase the basicity, b) decrease of the total activity in ODH, c) decrease in the selectivity to propene (except for the Ca additive). The effect of additives to VMg catalysts is compared with that reported in Part I for VSi catalysts, and reasons for opposite effect of the additives on the selectivity to propene (increase for VSi and decrease for VMg series) are suggested.
PL
W Kole Naukowym Mechaników ATR Bydgoszcz opracowano stanowisko do obserwacji procesu spalania w silniku spalinowym o zapłonie iskrowym. Zastosowano w nim świecę zapłonową z wziernikiem, przez który filmowano proces spalania. Do rejestracji video i zapisu obrazów zastosowano aparat cyfrowy. Dla wybranych klatek procesu spalania zrealizowanych przy różnych jakościowych nastawach mieszanki dokonano z zastosowaniem specjalnie opracowanego programu analizy koloru emitowanego światła. Przeprowadzone próby wskazały na celowość prowadzenia prób doboru składu mieszanki z zastosowaniem świec z wziernikiem. Sposób ten umożliwia optymalizację składu mieszanki w czasie rzeczywistym.
EN
The stand to combusting process observation in spark ignition engine is presented in paper. In this stand was used ignition plug with sight-glass through which combusting process was filmed. For recording used digital camera. Picture of combusting process was analysed with special software use.
17
Content available remote Analiza uszkodzeń sieci wodociagowej miasta Płocka w 2001 roku
PL
W pracy przedstawiono analizę uszkodzeń mechanicznych, korozyjnych i na złączach przewodów sieci wodociągowej miasta Płocka w 2001 roku. W ocenie uwzględniono rodzaje przewodów (magistrale, przewody rozdzielcze i przyłącza wodociągowe) oraz strukturę materiałową i wiekową sieci. W pracy dokonano porównania wskaźników uszkodzeń sieci wodociągowej miasta Płocka ze wskaźnikami uszkodzeń sieci wodociągowych o podobnej długości.
EN
The aim of this paper was to assess the mechanical, corrosive and on the pipe connections of water conduit, damages in Plock in the 2001 year. In the evaluation was taken into consideration kind of pipe (arterial, distributing pipe, water terminal) material and aged structure of water-pipe network. This work presents comparison of indicators of water-pipe network damages in Plock and similar length water-pipe network different cities.
18
EN
Commonly available hydrolytic enyzymes are capuble of recognizing heteroatom stereogenic centres. A review of the application of these enzymes in the preparation of optically active sulfur and phosphorus compounds, based on the results from the authors' Laboratory, is presented.
PL
Powszechnie dostępne enzymy hydrolityczne są w stanie rozpoznać stereogenne centra heteroatmowe. Niniejszy przegląd przedstawia zastosowanie tego typu enzymów w syntezie optycznie czynnych połączeń siarki i fosforu ze szczególnym uwzględnieniem wyników badań pochodzących z Laboratorium autorów.
EN
In the study of vanadium-phosphorus catalysts and related substances with the TPD/QMS of ammonia the higher resolution spectra have been obtained. They show the presence at the catalysts surface of two well resolved bands of weakly bonded ammonia (120-140° C) tentatively assigned to two kinds of surface phosphate groups of different acidity and the band of much stronger bonded ammonia (200° C) assigned to vanadate groups. Introduction of bismuth atoms increases the number of active phosphate groups and the strength of their acid function. The effect of lanthanum additives is opposite.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.