Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This article is focused on considerations based on experimental studies concerning changes of selected parameters of identical compact fluorescent lamps (CFLs) intended for use in buildings during their operation. The studies constituted a long-term experiment whose goal was an evaluation of selected operating parameters of the CFLs in terms of meeting the requirements set out in the specified regulations as well as the issue of marking the lamps with the energy efficiency class. The measurements were performed with the authors’ experimental setup consisting of original equipment designed and made especially for the purpose of the measurements. The studies covered registration of the luminous flux as well as selected electrical parameters such as active power, current and the power factor during the so-called “start-up time” and operation time equal to 100 h, 500 h, 1000 h, 2000 h, etc. with a 1000 h step. The studies were finished with the moment of natural burnout of the CFLs tested. The results showed that the biggest drawback of CFLs is lack of preservation of the required time to reach 60% of the stabilized luminous flux just after short time of lamp operation. Similarly when assessing the conformity of the parameters declared by the manufacturer that have been verified, it can be stated that they are true only at the initial stage of lamp operation.
EN
Age-dependent changes in human eye spectral sensitivity play an important role in contemporary lighting research. Nowadays lighting designing practices take into account the fact that an illuminance level perceived by a given observer depends also on his age. According to recommendations of the International Commission on Illumination CIE presented in the document 227:2017, users age should be taken into account in lighting design of public buildings. The natural consequence of this approach in designing should be the fact that the age of a user also should be considered when verification of lighting installation photometric parameters is performed. According to recommendations of latest CIE documents, verifications of illuminance levels are performed by luxmeters whose spectral sensitivity matches the CIE standard photometric observer V(λ) function. At present there is a lack of papers describing how the accuracy of illuminance measurements could be affected by the fact that with age there are changes in human eye spectral sensitivity and it differs from V(λ) function. To fill this gap we present in this article results showing how applying of different photometric observers influence the luxmeter accuracy. The calculations were performed for LED and FL light sources measured by class B and class C luxmeters. These results indicate that a luxmeter error f1 strongly depends on correlated color temperature of a lamp under measurement and spectral sensitivity of applied photometric observer.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.