EN
All of the buildings in TUKE campus are connected on water main as only one source of water. There is no building with alternative source of water for non-potable uses so that potable water is used for drinking purposes as well as all others activities (flushing toilets, cleaning..). Drainage solutions of the TUKE campus are in traditional way too. The buildings situated in TUKE campus have a classical drainage system for rainwater runoff consist from traditional direct channelling of surface water through networks of pipes to sewer system except two buildings - PK6 and PK5 which have a drainage system for rainwater runoff designed through the infiltration facilities - infiltration shafts. This paper describe a big potential savings of potable water by the use of rainwater in TUKE campus as well as the big potential for “green” drainage solution - infiltration in TUKE campus.
EN
There are many water sources available on building sites that can be use as a alternative water sources for supplement the more traditional water sources. These water sources are usually suitable for non-potable purposes and vary greatly in quality so that the most of the on-site water resources have limited application and of course are never suitable for human consumption. Rain-water harvesting appears to be one of the most promising alternatives for supplying freshwater in the face of increasing water scarcity and escalating demand. Advantage of the rainwater harvesting is availability in the most places over the world and that rainwater usually is one of the purest waters available of all the alternate water sources. Submitted paper contains an overview of the possible rain water use for non-potable purposes in one school buildings as well as a possibility of the rainwater harvesting for buildings in TUKE campus as a planned concept for rainwater management.
3
Content available remote Zero energy balance proposal for office buildings
EN
The paper discusses the issue of prediction of electric energy production using a photovoltaic system which is directly installed at the administrative building. The problem with solar energy, which has been transformed using photovoltaic systems for electricity, is the low capacity to accumulate an excess of produced electricity. This excess of electricity we link within the power grid to send outside the building where the energy was produced to be consumed elsewhere. In this way, we achieve the highest possible utilisation of electricity produced within the boundaries of the building itself. One option is to create opportunities to recharge electric vehicles during working hours, at the time when the production of electricity is the highest but the consumption of electricity is not.
PL
W artykule przedstawiono analizę przewidywanej produkcji energii elektrycznej z system fotowoltaicznego zainstalowanego bezpośrednio w budynku administracyjnym. Problemem z energią słoneczną, zamienianą przy użyciu systemów fotowoltaicznych w energię elektryczną, jest niska zdolność gromadzenia nadmiaru produkowanej energii elektrycznej. Ten nadmiar energii elektrycznej możemy przy połączeniu z siecią energetyczną wysłać poza granice budynku, w którym energia została wytworzona i zastosować w innym miejscu. W ten sposób możemy najlepiej wykorzystać energię elektryczną wytwarzaną w granicach budynku. Jedną z opcji jest stworzenie możliwości ładowania pojazdów elektrycznych w czasie godzin pracy, kiedy poziom produkcji energii jest najwyższy, a zapotrzebowanie na energię nie jest na wysokim poziomie.
4
Content available remote Research and evaluation of infiltration shaft efficiency in real conditions
EN
Infiltration of rainwater runoff as a disposal method of rainwater runoff, become an integral part of rainwater management. Infiltration of water from surface runoff has over conventional disposal of rainwater, i.e. draining into the sewer system and next to surface water a number of benefits especially from the environmental, technical and economic point of view. Infiltration facility is a device designed for fluent and natural infiltration of rainwater incoming from the roofs of buildings and paved surfaces into the underground space. The basic principle and function of all types of infiltration systems and facilities as quickly as possible to drain rainwater into the underground space and there it with a time delay infiltrate into the surrounding soil.
5
Content available remote Water management problems in modern cities
EN
Water is one of the most valuable natural resources on Earth; therefore “the water topic” should be one of the most important themes of discussion for us. Water management consists of hundreds of subtopics. Only one of the water management subtopics is shortly described in this paper: stormwater management (SWM). Stormwater causes major problems in the cities where more and more impervious surfaces contribute to more extensive and faster runoff which may lead to the overloading of the sewerage systems and consequently create urban flooding as well. This article briefly describes how urbanization has changed urban runoff and what sustainability means in the context of SWM as well as presents our research carried out in this respect at the Faculty of Civil Engineering.
PL
Woda to jedno z najcenniejszych bogactw naturalnych na Ziemi, dlatego też „temat wodny” winien stanowić jeden z najistotniejszych wątków naszej dyskusji. Gospodarka wodna składa się z setek podtematów. W niniejszym artykule pokrótce opisano zaledwie jeden z nich, a mianowicie zarządzanie wodą opadową (storm water management – SWM). Woda opadowa przysparza najwięcej kłopotów miastom, w których wzrastająca ilość powierzchni nieprzepuszczalnych przyczynia się do rozleglejszego i szybszego odpływu, co może prowadzić do przeładowania systemów kanalizacyjnych, a w konsekwencji do zalewania terenów miejskich. Wyjaśniono, w jaki sposób urbanizacja zmieniła strukturę odpływów i co oznacza rozwój zrównoważony w kontekście SWM, a także przedstawiamy autorskie badania prowadzone w tym zakresie na Wydziale Inżynierii Wodno-Lądowej.
6
Content available remote Heat pumps as a renewable energy source for administrative buildings
EN
The Economic Research Centre for Renewable Energy Sources and Distribution Systems was founded with the purpose to investigate the possibilities of reducing the energetic costs of buildings. The Centre creates a real environment for research on progressive technologies. We evaluate the operational behaviour of a zero-energy balance building, an interaction with its constructions, a study of the inner climate parameters and the overall results for a central heat supply system.
PL
Ośrodek Badań Gospodarczych w zakresie Odnawialnych Źródeł Energii i Systemów Dystrybucji został założony w celu badania możliwości ograniczania energetycznych kosztów utrzymania budynków. Ośrodek ten tworzy prawdziwe środowisko do badań technologii progresywnych, zajmuje się oceną operacyjnego zachowania budynku zero-energetycznego, wzajemnego oddziaływania pomiędzy konstrukcjami budynku, parametrów klimatu wewnętrznego oraz ogólnych wyników w odniesieniu do centralnego systemu grzewczego.
7
Content available remote Hot water (PWH) systems from hygienic and energetic point of view
EN
People often keep the temperature in PWH tanks set Iow to save electricity and prevent scalding. To kill off the legionnaires bacteria is recommended temporarily turning up the temperature to above 60°C, especially if people prone to the infection are using the water. Large water heaters frequently contain cool zones near the base where cold water enters and scale and sediments accumulate. Design water systems designed to recirculate water and minimize dead legs will reduce stagnation. If potential for scalding exist, appropriate, fail - safe scald protection equipment should be employed. Point of-use water heaters can eliminate stagnation of hot water in frequently used lines. Proper insulation can help maintain distribution and delivery temperatures.
PL
W celu oszczędności energii i zapobieganiu sparzaniu ludzie zwykle utrzymują temperaturę w zbiornikach wodnych na niskim poziomie. Aby zabić bakterie Legionnela zaleca się okresowe podnoszenie temperatury do ponad 60°C, szczególnie gdy ludzie skłonni do zarażenia używają wody z takiego zbiornika. Duże podgrzewacze wody często zawierają chłodne strefy w pobliżu podstawy, gdzie wpływa zimna woda i gromadzi się kamień i osady. Zaprojektowany system wodny zapewniający recyrkulację wody i minimalizujący martwe odcinki redukuje zastoje. W przypadku istnienia niebezpieczeństwa sparzania powinno być zainstalowane odporne na uszkodzenia wyposażenie przeciw sparzaniu. Miejscowe grzejniki wody pozwalają wyeliminować zastoje ciepłej wody w często używanych odcinkach. Właściwa izolacja pomaga utrzymać rozdział i dostarczenie temperatury.