Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
W artykule przedstawiono opis katastrofy budowlanej powstałej w wielokondygnacyjnym budynku usługowo-mieszkalnym pochodzącym z przełomu XIX i XX wieku. Katastrofa powstała podczas prowadzonych robót budowlanych mających na celu zmianę sposobu użytkowania usługowych pomieszczeń parteru. Opisano zakres prowadzonych robót oraz popełnione błędy projektowe i wykonawcze, które doprowadziły do katastrofy.
EN
In this article was presented the catastrophe of residential-service building which was built in the late 19th and early 20th centuries. The collapse of the building began during refurbishment building works which aimed to change the usage of the ground floor of building. In this paper were presented the scope of building works as well as design and execution faults which caused the catastrophe.
PL
Prefabrykowane stropy belkowo-pustakowe DZ-3 w latach 70. ubiegłego stulecia stanowiły jedno z popularnych rozwiązań konstrukcyjno-technologicznych stropów budynków mieszkalnych i użyteczności publicznej. W tych latach powstał również przedmiotowy budynek, o ww. konstrukcji stropów. W wyniku niezgodnego z założoną funkcją użytkowania obiektu, a również błędów poczynionych w fazie projektowania i wykonawstwa doszło do awarii stropów DZ-3. W artykule opisano główną konstrukcję budynku, przyczyny powstania awarii, pomiary, wyniki obliczeń sprawdzających i wnioski.
EN
Prefabricated beam-hollow brick DZ-3 ceilings, back in the 1970’s, have been one of the most popular structural-technological solutions, when it came to the ceilings of the residential and public utility buildings. The subject building utilizing the above-described ceiling structure, has also been erected within that period. Due to the usage of the building which was not compliant with the assumed function, as well as due to the design and construction errors, the DZ-3 ceilings have been damaged. The present article describes the main structure of the building, causes of the damage, measurements, results of calculations and conclusions. The applied methodology and repairs have been presented.
PL
W pracy zaprezentowano stan przedawaryjny konstrukcji dachu oraz gzymsów zabytkowego kościoła w Wodzisławiu Śląskim pod wezwaniem Wniebowzięcia NMP. Wskutek działania niekorzystnych oddziaływań oraz niedoszacowania przekrojów wystąpiły nadmierne poziome przemieszczenia murłat konstrukcji dachu. Odkształcenia te spowodowały uszkodzenia gzymsów znajdujących się w bezpośrednim sąsiedztwie nadmiernie ugiętych murłat. W referacie przedstawiono analizę możliwych przyczyn uszkodzenia oraz sposób naprawy.
EN
In the paper, the pre-failure state of the roof structure and the cornices of historic church of Blessed Virgin Mary located in Wodzisław Śląski was presented. Due to adverse influences and underestimation of the cross-sections of elements, excessive horizontal deformations of the wall plates took place. In consequence, closely built-in cornices were damaged too. In this article, the possible reasons of damages were analyzed and the method of repair was described.
4
Content available Testing timber beams after 130 years of utilization
PL
W Polsce, drewno to materiał konstrukcyjny kojarzony głównie jako historyczny budulec chat drewnianych lub obiektów sakralnych na terenach wiejskich, a także obiektów inżynierskich, takich jak mosty czy kładki dla pieszych. W bardziej współczesnych zastosowaniach drewno wykorzystywano przede wszystkim do wykonywania konstrukcji nośnej dachów(na więźby o różnych schematach statycznych i różnych układach nośnych) oraz jako elementy nośne stropów drewnianych. Dawniej z uwagi na stosunkowo duże zalesienie obszaru Polski, pozyskanie drewna dla inwestycji nie sprawiało trudności. Jednak zagadnienia ponownego użycia całych elementów drewnianych wbudowanych w wielu obiektach, są w naszym kraju praktycznie nieznane. Do badań laboratoryjnych udało się pozyskać 130 letnie stropowe belki drewniane z remontowanego zabytkowego budynku. Pierwotny strop, z którego pozyskano belki do badań, wykonany był jako belkowy ze ślepym pułapem i polepą. Elementy badawcze dostarczone do laboratorium posiadały widoczne pozostałości po stropie - w postaci gwoździ, łat ślepego pułapu i inne zanieczyszczenia. Stan techniczny pozyskanych belek był w większości dobry z widocznymi podłużnymi spękaniami. W niektórych belkach były widoczne ślady żerowania owadów oraz widoczna korozja biologiczna. W referacie przedstawiono badania laboratoryjne belek drewnianych po 130 latach użytkowania oraz ocenę ich parametrów technicznych według obowiązujących przepisów normowych. Wykonano również badania na zginanie dla małych próbek pozyskanych z przebadanych wcześniej belek oraz porównano do badań w skali naturalnej. W wyniku przeprowadzonych badań wstępnie można stwierdzić, że odzyskiwanie starych belek z rozbieranych budynków jest możliwe. Nie znając parametrów pierwotnych trudno określić w jakim stopniu drewno obniżyło swoją wytrzymałość. Niemniej jednak w wyniku przeprowadzonych wstępnych badań na belkach pełnowymiarowych pozyskanych z 130 letniego obiektu stwierdzono, że parametry wytrzymałościowe drewna są dobre i pozwalają na powtórne wykorzystanie. Na korzyść drewna starego przemawia również fakt, iż belki stare mimo istniejących wad są już ustabilizowane wymiarowo. Porównano również wyniki badań drewna przy zginaniu na małych próbkach z badaniami belek w skali naturalnej. Po przeprowadzeniu analizy otrzymanych wyników stwierdzono dużą zbieżność końcowych wyników oszacowania wytrzymałości charakterystycznej badanego drewna. Co może wskazywać, iż wykonywanie badań na małych próbkach i ich analiza wg EN 384 jest miarodajna. Należy jednak ostrożnie interpretować to porównanie z uwagi na niewielką ilość badanych modeli.
EN
In Poland, timber as a structural material is mainly associated with a historical building material of wooden cottages or sacred buildings in rural areas, as well as engineering facilities such as bridges or footbridges. In more contemporary applications, first of all timber is used for roof load-bearing structure (rafter framing in different static schemes and load carrying systems) and for timber floor load-bearing elements. In the past obtaining wood was not difficult due to quite large afforestation of Poland. However, the problems of the reuse of whole wooden elements built-in in the structures are practically unknown in our country. Laboratory tests were carried out on 130-year-old wooden floor beams obtained from the monumental building under renovation. Original floor, whose beams were used for testing, was first made as beam-framed floor with sound boarding and ceiling. Testing elements delivered to the laboratory had got vivid restages of old floor - in the form of nails, sound boarding lathes and other impurities. Technical condition of the obtained beams was in the majority of cases good with visible longitudinal cracks. In some of the beams insects feeding well as biological corrosion marks were present. The paper presents results of laboratory testing on timber beams after 130 years of utilization and evaluation of their technical parameters according to binding standard regulations. Additionally bending tests were carried out on little samples obtained from previously tested beams and compared to tests in natural scale. As a results of the carried out laboratory tests it was preliminary noted that reclamation of old beams from demolished buildings is possible. If we do not know the original parameters of the timber it is hard to determine the level of strength loss. However, as a result of preliminary tests of full dimension beams obtained from 130 years old building it can be noted that strength parameters of old timber are good and they enable timber reuse. The advantage of old timber is also fact that old beams in spite of existing defects are dimensionally stabilized. The results of timber bending testing on little samples have been compared with results of testing of beams in natural scale. Having analysed the received results, great similarity of final results of estimated characteristic strength of the tested timber has been noted. It may indicate that testing on little samples and their analysis according to EN 384 is reliable. However, interpretation of such a comparison shall be careful due to small number of tested models.
PL
W artykule przedstawiono przykłady uszkodzeń budynków mieszkalnych i gospodarczych, stanowiących zwartą zabudowę jednorodzinną, w wyniku działania trąby powietrznej 15 sierpnia 2008 r.
EN
This paper presents the examples of damages of residential and farm buildings forming the compact built-up area, due to tornado in 15th August 2008.
PL
W artykule przedstawiono opis konstrukcji parterowego budynku basenu kąpielowego wykonanego w technologii szkieletu drewnianego. W wyniku błędów projektowych i wykonawczych, po kilku latach użytkowania obiektu wystąpił stan awaryjny konstrukcji nośnej szkieletu spowodowany butwieniem drewna. Przedstawiono sposób wymiany uszkodzonych elementów oraz jego realizację.
EN
Structure of one floor building of swimming pool realized as a skeleton made out of timber is presented. Failure of structure was a result of decay of wood after just few years of exploitation. Paper presents a realization of damage repair.
9
Content available Drewniana zabytkowa wieża radiostacji w Gliwicach
PL
Wieża telekomunikacyjna w Gliwicach, o wysokości 110,7 m, została wzniesiona w 1933 roku jako przestrzenna konstrukcja kratowa, w całości z modrzewiowego drewna. Wszystkie połączenia wykonano na śruby i sworznie mosiężne. Podczas 70 lat ciągłej eksploatacji wieża była kilkakrotnie badana i zabezpieczana, ale były także długie okresy bez odpowiedniej konserwacji. Od 1998 roku konstrukcję poddano starannym obserwacjom i pomiarom. Stwierdzono wiele zmian w geometrii węzłów, jak też uszkodzeń prętów drewnianych. Na podstawie badań i analiz komputerowych przyjęto zakres niezbędnych wzmocnień. Wieża jest na tyle wiekowa, że jest traktowana jako zabytek techniki, a zatem metody napraw i wzmocnień są ograniczone. Specjalną metodę wzmocnienia za pomocą taśm z włókien węglowych wprowadzono w najsilniej wytężonych prętach; zalecono także ogólną impregnację drewna.
PL
Omówiono właściwości i badania modelowe drewnianych prętów rurowych złożonych z listew i sprężonych prostopadle do włókien, stanowiących propozycję nowych elementów konstrukcyjnych. Przedstawiono wyniki badań prętów oraz przykłady możliwych zastosowań konstrukcyjnych.
EN
Some features and model investigation of tubular members made of wooden battens and spirally prestressed are described. Investigation of described members and their possible application in construction are reported.
EN
In drilling waste management, before burial and trenching the waste solidification process is often carried out as an effective measure to decrease the waste potential harmfulness for environment. The increase of contaminant retention and the change of mechanical structure of waste are the advantages of this process. The paper presents the results of investigation aimed at choosing the solidification conditions for drilling wastes of different characteristic and the assessment of solidification process effectiveness. It also comments on process effectiveness in laboratory tests and in field operations.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.