Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
River intermittence was studied based on data from hydrological monitoring in Poland. We screened the entire state database and two another data sources applying the criterion for zero-flow event: discharge less than 0.0005 m3∙s-1, and found five intermittent rivers with catchment area from 9.2 to 303.7 km2. We aimed at finding associations between intermittence and climatic driving forces (temperature and precipitation), and between intermittence and anthropogenic activity. We used the Spearman correlation coefficient, circular statistics, and statistical tests for trend. The concentration of zero-flow days, mostly in summer, and the decreasing trend in the standardised precipitation evapotranspiration index (SPEI) in all catchments at various aggregation levels, and an increasing trend in the total number of zero-flow days and in the maximum length of zero flow events in two rivers, were detected. The strong negative correlation (–0.62 ≤ ρ < 0) between intermittence and the SPEI backward lagged in time showed that intermittence resulted from prolonged deficits in climatic water balance due to increasing evapotranspiration. The reaction of the Noteć catchment, amplified by the anthropogenic pressure (brown coal mines), was reflected in the atypical shape of the rose diagram and in inhomogeneities in river discharges. The results show that the rose diagram can serve as an indicator of the degree of anthropogenic impact on runoff conditions.
EN
Due to insufficient operation efficiency, the studied treatment plant has undergone modernization. The aim of this study was to assess whether this modernization improved quality of the STP effluent and water quality in the receiver. The research period of fifty months covered time before and after the modernization. Samples were collected in four sites – upstream and downstream of the STP and by the sewage discharge. Electrolytic conductivity, water temperature and pH were measured onsite. Chemical analyzes were based on ion chromatography and determined the concentration of NH4+, NO3-, NO2-, PO43-, TDS. Microbiological analysis comprised serial dilutions to assess the number of mesophilic and psychrophilic bacteria and membrane filtration to enumerate E. faecalis, total and fecal coliforms as well as total and fecal E. coli. Values of most analyzed parameters did not improve after the modernization, or improved for a very short period of time (NH4+), while some of them even increased, such as PO43-, total and thermotolerant coliforms and E. coli. The maximum value of thermotolerant E. coli reached nearly 7 million CFU/100 ml and was observed after modernization. Also at the sites situated downstream of the STP some of analyzed parameters increased. The conducted modernization did not improve the quality of treated sewage and even a further deterioration was observed. It could have been a result of rapidly growing number of tourists visiting the studied area, thus generating large amounts of sewage causing STP overload coupled with poor water and wastewater management. Significant percentage of unregistered tourists hinders proper assessment of the STP target efficiency.
PL
Z powodu niewystarczającej efektywności, badana oczyszczalnia ścieków została poddana modernizacji, a celem badań była ocena czy modernizacja ta poprawiła jakość ścieków wypływających z oczyszczalni i jakość wody w odbiorniku. Okres badań (50 miesięcy) objął czas przed i po modernizacji. Próbki pobrano w czterech punktach – przed i za oczyszczalnią oraz przy zrzucie ścieków. Przewodnictwo elektrolityczne, temperaturę i pH wody mierzono na miejscu. Analizy chemiczne oparto na chromatografii jonowej i oznaczono stężenia NH4+, NO3-, NO2-, PO43-, TDS. Analizy mikrobiologiczne obejmowały oznaczenie liczby bakterii mezofilnych i psychrofilnych techniką seryjnych rozcieńczeń oraz filtrację membranową w celu oznaczenia liczebności E. faecalis, bakterii grupy coli i E. coli całkowitych i kałowych. Wartości większości badanych parametrów nie uległy poprawie po modernizacji lub poprawiły się na bardzo krótki okres (NH4+), natomiast wartości niektórych wzrosły, np. PO43-, bakterii grupy coli i E. coli. Maksymalną liczebność termotolerancyjnych E. coli – niemal 7 milionów jtk/100 ml – stwierdzono w okresie po modernizacji. Również w punktach położonych za oczyszczalnią nastąpił wzrost niektórych analizowanych parametrów. Przeprowadzona modernizacja nie poprawiła jakości mikrobiologicznej oczyszczanych ścieków, a nawet stwierdzono dalsze jej pogorszenie. Może być to wynikiem gwałtownie rosnącej liczby turystów odwiedzających badany region, generujących ogromne ilości ścieków powodujących przeciążenie oczyszczalni, a także może być spowodowane słabą gospodarką wodno-ściekową. Znaczny odsetek turystów, których pobyt nie jest rejestrowany, utrudnia właściwe zaprojektowanie docelowej skuteczności oczyszczalni ścieków.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.