Purpose: This study addresses the brittle fracture propagation behaviour modelling of hydroxyapatite (HAp) coating in artificial femoral stem component. Design/methodology/approach: A simple two dimensional flat-on-flat contact configuration finite element model consisting contact pad (bone), Ti-6Al-4V substrate and HAp coating is employed in static simulation. The HAp coating is modelled as elastic layer with pre-microcrack which assumed to be initiated due to stress singularity. Findings: The study revealed that reducing coating thickness, pre-microcrack length and artificial femoral stem elastic modulus along with increasing bone elastic modulus will result in significant stress intensity factor (SIF) to promote brittle fracture propagation behaviour. Research limitations/implications: The influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on fracture behaviour is examined under different stress ratio using J-integral analysis approach. Practical implications: The proposed finite element model can be easily accommodating different Hap coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus to perform detailed parametric studies with minimal costly experimental works. Originality/value: Limited research focussing on brittle fracture propagation behaviour of HAp coating in artificial femoral stem component. Thus, present study analysed the influence of coating thickness, pre-microcrack length, bone and artificial femoral stem elastic modulus on stress intensity factor (SIF) of HAp coating.
Purpose: Present paper addresses the formulation of delamination-fretting wear failure predictive equation in HAp-Ti-6Al-4V interface of hip arthroplasty femoral stem component using multiple linear regression model. Design/methodology/approach: A finite element computational model utilising adaptive meshing algorithm via ABAQUS/Standard user subroutine UMESHMOTION is developed. The developed FE model is employed to examine effect of different HAp-Ti-6Al-4V interface mechanical and tribological properties on delamination-fretting wear behaviour. The FE result is utilised to formulate predictive equations for different stress ratio conditions using multiple linear regression analysis. Findings: Delamination-fretting wear predictive equations are successfully formulated with significant goodness of fit and reliability as a fast failure prediction tool in HAp coated hip arthroplasty. The robustness of predictive equations is validated as good agreement is noted with actual delamination-fretting wear results. Research limitations/implications: The influence of different mechanical and tribological properties such as delamination length, normal loading, fatigue loading, bone elastic modulus and cycle number under different stress ratio on delamination-fretting wear failure is analysed to formulate failure predictive equations. Practical implications: The formulated predictive equation can serve as a fast delamination-fretting wear failure prediction tool in hip arthroplasty femoral stem component. Originality/value: Limited attempt is done to explore the potential of utilizing multiple linear regression model to predict failures in hip arthroplasty. Thus, present study attempt to formulate delamination-fretting wear failure predictive equation in HAp -Ti-6Al-4V interface of hip arthroplasty femoral stem component using multiple linear regression model.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.