Content available remote New structure for three-phase, four-wires shunt active filter
EN
This paper presents a new structure and control method for three phase four wires LC coupled parallel active power filters (APF) for harmonics cancellation. The main differential point with regard to other structures used in the past consists of the connection of neutral wire to negative of DC bus in the inverter, thus avoiding the need of split capacitors at the DC bus. The LC coupling and a particular control of the DC voltage at the coupling capacitor allow the use of low voltage at the DC bus and provide a symmetry of available voltage, in the current controller, during ton and toff. The paper includes a general discussion of the new structure, comparing it with the classical L coupled shunt APFs and presents the control method to obtain the above mentioned voltage symmetry, which allows lower DC bus voltage and lower values of coupling L. Simulation and experimental results are given to show the behavior of the system, used for harmonics cancellation.
PL
W artykule przedstawiono nową strukturę oraz metodę sterowania trójfazowego-czteroprzewodowego równoległego filtru aktywnego (APF) sprzężonego z siecią zasilającą za pomocą szeregowego obwodu LC, przeznaczonego do redukcji harmonicznych. Główna cechą zaproponowanej struktury, wyróżniającą ją spośród innych rozwiązań układów APF, jest połączenie przewodu neutralnego sieci zasilającej z ujemną szyną DC falownika, przez co unika się potrzeby zastosowania dzielonego kondensatora. Natomiast, sprzężenie LC układu APF z siecią zasilającą oraz kontrola napięcia stałego na poszczególnych kondensatorach sprzęgających pozwalają stosować niskie napięcie na szynach DC, a także osiągnąć symetrię napięcia podawanego na sterownik prądu w przedziałach załączania ton i wyłączania toff tranzystorów. Niniejszy artykuł zawiera ogólne omówienie nowej struktury oraz porównanie z klasycznymi układami APF z dławikami sprzęgającymi L. Ponadto, przedstawiono metodę sterowania umożliwiającą uzyskanie wspomnianej wyżej symetrii napięcia i, w konsekwencji, zmniejszenie napięcia na szynach DC oraz wartości dławików w obwodach sprzęgających LC. Właściwości zaproponowanego rozwiązania ilustrują wyniki symulacji i badań eksperymentalnych.
2
Content available remote Angle estimation for permanent magnet synchronous machines using matrix converters
EN
This paper deals with the rotor angle estimation of Permanent Magnet AC Machines using test voltage vectors. In concrete, due to the machine saliency (difference between Ld and Lq) and the application of pulse voltage test vectors is possible to estimate the Permanent Magnet position for further low and zero speed Sensorless Control. The novelty of this paper is the fact that a Matrix Converter is used instead of the conventional Voltage Source Inverter. The direct AC/AC or Matrix Converter is a novel topology of great interest in specific wind energy applications since it avoids the use of electrolytic DC coupling capacitors, which is a potential source of failures. The paper presents the position signals for Matrix Converters and shows all the control algorithm. Finally, some simulation results with proper angle estimation, when speed reversal, corroborates the proper functionality of the control scheme.
PL
Artykuł dotyczy estymacji kąta położenia wirnika maszyny prądu przemiennego o magnesach trwałych z wykorzystaniem próbnych wektorów napięcia. Konkretnie, w związku z asymetrią magnetyczną maszyny (różnica między Ld i Lq) oraz zastosowaniem napięciowych impulsów wektorów próbnych, jest możliwa estymacja położenia magnesów trwałych, pozwalająca na bezczujnikowe sterowanie w zakresie niskich i zerowych prędkości. Nowością w artykule jest zastosowanie przekształtnika matrycowego zamiast tradycyjnego falownika napięcia. Przekształtnik matrycowy (bezpośredni przekształtnik AC/AC) jest nowym układem budzącym duże zainteresowanie w specyficznych aplikacjach, związanych z energią wiatru, ponieważ unika się zastosowania kondensatorów elektrolitycznych DC stanowiących potencjalne źródło uszkodzeń. W artykule przedstawiono sygnały ustalające położenie wirnika oraz pełny algorytm sterowania przekształtników matrycowych. Poprawne działanie algorytmu z estymacją kąta potwierdzają wyniki symulacji przy zmianie kierunku wirowania.