Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The objective of this study was to develop and validate a novel, simple, and selective high-performance liquid chromatographic (HPLC) method with photodiode array detector for the estimation of tenofovir in rat plasma, which can be utilized in analyzing the pharmacokinetic samples from rats. Prior to analysis, an optimized protein precipitation technique was used to extract tenofovir from plasma. The mobile phase for this method comprised of 10 mM ammonium acetate buffer (pH 4) and methanol in the ratio of 97:3 υ/υ. Chromatographic separation of tenofovir was achieved using Spincotech C-18G enabled column (250 × 4.6 mm, 5 μm). Tenofovir was monitored at a wavelength of 260 nm, and the calibration curve was linear in the range of 250–4000 ng mL−1 (R2 = 0.999). High recovery obtained after extraction (97%–101%) of plasma samples precluded the use of an internal standard. Validation studies were performed as per the standard guidelines, and the developed method was accurate, precise, and selective for the determination of tenofovir in the rat plasma. The stability studies performed during the sample pretreatment process and sample storage conditions did not show a quantifiable degradation of tenofovir. Further, this method was able to estimate tenofovir and determine its pharmacokinetic parameters, post IV bolus administration in male Wistar rats. The pharmacokinetic profile of tenofovir followed one compartmental open model.
EN
A rapid and sensitive reverse-phase liquid chromatographic method using ultraviolet detector was developed and validated for estimation of raloxifene hydrochloride in rabbit plasma. Plasma samples were extracted using simple protein precipitation-extraction method. The method was developed under isocratic conditions using a Zorbax SB-C8 analytical column with optimum mobile phase composition of 20 mM pH-4.5 ammonium acetate buffer-acetonitrile (63:37 υ/υ) at a flow rate of 1 mL min-1. The detector response was found to be linear in the concentration range of 50–1500 ng mL-1. High recoveries ranging from 97.2% to 100.2% were obtained, which precludes the use of internal standard. The developed method was found to be accurate, precise, and selective in the estimation of raloxifene hydrochloride in rabbit plasma based on the results of method validation carried out as per standard guidelines. The drug was found to be stable under various processing and storage conditions. The developed method was successfully applied in the estimation of raloxifene hydrochloride and the determination of various pharmacokinetic parameters post-intravenous bolus administration of drug in rabbits.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.