Kidney Cooling Jacket (KCJ) preserves the kidney graft, wrapped in the jacket, against the too fast time of temperature rise during the operation of connecting a cooled transplant to the patient’s bloodstream. The efficiency of KCJ depends on the stationarity of the fluid flow and its spatial uniformity. In this paper, the fluid velocity field inside the three different KCJ prototypes has been measured using the 20 MHz ultrasonic Doppler flowmeter. The simplified 2D geometrical model of the prototypes has been presented using COMSOL-Multiphysics to simulate the fluid flow assuming the laminar flow model. By comparing the numerical results with experimental data, the simplified 2D model is shown to be accurate enough to predict the flow distribution of the internal fluid velocity field within the KCJ. The discrepancy between the average velocity measured using the 20 MHz Doppler and numerical results was mainly related to the sensitivity of the velocity measurements to a change of the direction of the local fluid flow stream. Flux direction and average velocity were additionally confirmed by using commercial colour Doppler imaging scanner. The current approach showed nearly 90% agreement of the experimental results and numerical simulations. It was important for justifying the use of numerical modelling in designing the baffles distribution (internal walls in the flow space) for obtaining the most spatially uniform field of flow velocity.
EN
Acoustical Driving Forces (ADF), induced by propagating waves in a homogeneous and inhomogeneous lossy fluid (suspension), are determined and compared depending on the concentration of suspended particles. Using integral equations of the scattering theory, the single particle (inclusion) ADF was calculated as the integral of the flux of the momentum density tensor components over the heterogeneity surface. The possibility of negative ADF was indicated. Originally derived, the total ADF acting on inclusions only, stochastically distributed in ambient fluid, was determined as a function of its concentration. The formula for the relative increase in ADF, resulting from increased concentration was derived. Numerical ADF calculations are presented. In experiments the streaming velocities in a blood-mimicking starch suspension (2 μm radius) in water and Bracco BR14 contrast agent (SF6 gas capsules, 1 μm radius) were measured as the function of different inclusions concentration. The source of the streaming and ADF was a plane 2 mm diameter 20 MHz ultrasonic transducer. Velocity was estimated from the averaged Doppler spectrum obtained from originally developed pulsed Doppler flowmeter. Numerical calculations of the theoretically derived formula showed very good agreement with the experimental results.
EN
Objectives: In the article we describe the new, high frequency, 20 MHz scanning/Doppler probe designed to measure the flow mediated dilation (FMD) and shear rate (SR) close to the radial artery wall. Methods: We compare two US scanning systems, standard vascular modality working below 12 MHz and high frequency 20 MHz system designed for FMD and SR measurements. Axial resolutions of both systems were compared by imaging of two closely spaced food plastic foils immersed in water and by measuring systolic/diastolic diameter changes in the radial artery. The sensitivities of Doppler modalities were also determined. The diagnostic potential of a high frequency system in measurements of FMD and SR was studied in vivo, in two groups of subjects, 12 healthy volunteers and 14 patients with stable coronary artery disease (CAD). Results: Over three times better axial resolution was demonstrated for a high frequency system. Also, the sensitivity of the external single transducer 20 MHz pulse Doppler proved to be over 20 dB better (in terms of a signal-to-noise ratio) than the pulse Doppler incorporated into the linear array. Statistically significant differences in FMD and FMD/SR values for healthy volunteers and CAD patients were confirmed, p-values < 0:05. The areas under Receiver Operating Characteristic (ROC) curves for FMD and FMD/SR for the prediction CAD had the values of 0.99 and 0.97, respectively. Conclusions: These results justify the usefulness of the designed high-frequency scanning system to determine the FMD and SR in the radial artery as predictors of coronary arterial disease.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.