Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 15

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Badanie systemu kablowego 220 kV
PL
W artykule przedstawiono wyniki projektu firmy Tele-Fonika Kable S.A. realizowanego we współpracy z Instytutem Energetyki w Warszawie. Projekt obejmował wykonanie badania typu systemu kablowego 220 kV zgodnie ze standardem IEC 62067:2011. Praca obejmuje opis badanego systemu kablowego WN, program badań nieelektrycznych i elektrycznych oraz wyniki przeprowadzonych testów.
EN
This article describes the results of the project conducted by TELE-FONIKA Kable S.A. in cooperation with the Institute of Power Engineering from Warsaw. The project was devoted to testing 220kV cable system in accordance with the IEC 62067:2011 standard. The article contains the description of the HV cable system tested, schedule of non-electrical and electrical tests and the results of the tests conducted.
EN
The paper describes selected studies in the field of lightning and their effects carried out over the years at the Rzeszow University of Technology, which used modular impulse generators MIG0618SS and MIG0600MS. This apparatus dedicated to testing of avionics to induced lightning transients in accordance with DO-160 standard has also proved useful for other applications. The analysis of the previous research was done in terms of the applied solutions of test experimental setups and the parameters and configurations of the impulse generators.
PL
Artykuł przedstawia wybrane badania w obszarze oddziaływań wyładowań atmosferycznych, w których wykorzystano modułowe generatory udarów prądowych i napięciowych, służące do prób odporności awioniki na wtórne efekty wyładowań atmosferycznych. Skupiono się głównie na przedstawieniu dotychczasowych badań pod kątem zastosowanych rozwiązań konfiguracyjnych oraz zadanych parametrów udarów.
3
EN
The paper presents the results of preliminary laboratory tests of impulse current distribution in a model of the lightning protection system (LPS). The wooden frame house was prepared in a scale 1:5. It was based on the full size object subjected to lightning currents during open air experiments at the test side in Huta Poręby near Rzeszów. It was equipped with the model of the lightning protection system connected to the supplying electrical installation. The surge current injected to the tested system in the laboratory was produced with use of the lightning transient generator. Measurements were done for three varied shapes of the injected impulse current. The obtained results indicated the frequency dependent behaviour of the tested system. The current distribution in the proposed laboratory model of LPS is similar to those achieved during the tests on the real scale objects in recent years.
PL
drewniany szkielet budynku mieszkalnego, odwzorowujący obiekt używany do poligonowych badań rozpływu prądów udarowych w jego instalacjach piorunochronnej oraz elektrycznej, prowadzonych w Hucie Poręby niedaleko Rzeszowa. Zaproponowany model odzwierciedla istniejącą na poligonie instalację odgromową wraz z przyłączoną do niej niezasiloną typową elektryczną instalacją w postaci wewnętrznej sieci elektrycznej nn wraz z osprzętem, dochodzącej do złącza kablowego ziemnej linii kablowej nn, stacji transformatorowej i linii napowietrznej SN. Pomiarów dokonano dla trzech różnych kształtów wstrzykiwanego prądu udarowego. Uzyskane rozpływy prądów impulsowych są zbliżone do tych, obserwowanych podczas poligonowych badań pełnowymiarowych systemów przez ostatnie lata. Badany model wykazuje zależny od częstotliwości charakter.
4
PL
W artykule przedstawiono wyniki badań poligonowych oraz symulacyjnych, rozpływu składowej długotrwałej prądu piorunowego w urządzeniu piorunochronnym, kablowej linii zasilającej i instalacji elektrycznej budynku jednorodzinnego. Badania przeprowadzono w 2014 roku na poligonie badawczym Politechniki Rzeszowskiej w miejscowości Huta Poręby. Rozpływ prądu w poszczególnych elementach badanego obiektu mierzono i rejestrowano za pomocą wielotorowego elektrooptycznego układu pomiarowego. Dla weryfikacji wyników pomiarów, przeprowadzono badania symulacyjne rozpływu prądu udarowego w elementach obiektu zamodelowanego w programie ATP-EMTP. Parametry schematu zastępczego urządzenia piorunochronnego badanego obiektu, w tym poziomych i pionowych uziomów , wyznaczono na podstawie ich wymiarów geometrycznych oraz wartości rezystywności gruntu. Wyniki badań komputerowych wykazały dobrą zgodność z rejestracjami eksperymentalnymi. Różnice wynikają głównie z przyjętych założeń upraszczających w modelu układu i generatora.
EN
The first controlled experimental study of lightning continuous current distribution in the lightning protection system supplied with the electrical system was conducted in 2014 at the open site in Huta Poręby, Poland. The measurement results show that the surge current distribution depends on the individual grounding resistance, as well as, the length of the circuit. This relationship is clear in the case of large differences between the values of grounding resistance. For slight differences in these values, that is of the order of several percent, a stronger influence on the current distribution have a reactance of the lightning protection system. The obtained results were compared to those obtained during previous tests conducted in Florida and Huta Poręby regarding of the distribution of lightning return stroke currents. It turns out that the relationship of amplitudes of the currents in the individual parts of the lightning protection system with respect to the relationship between the grounding resistances are very similar. However, the continuous current components have the same shape in the different conductors of lightning protection system, differently than in the case of return stroke components. It means that the impact of frequency dependent grounding impedance on the shape of continuous current components is much smaller than in the case of much faster return stroke components. The effectiveness of lightning continuous current dissipation to the ground locally is a few percent larger than for return stroke currents. The obtained valuable measurements provide an incentive for further experimental and computational research in order to better know the most important conditions affecting the distribution of continuous current in the lightning protection system.
5
Content available remote Synteza termojądrowa : przyszłość energetyki
PL
W artykule przedstawiono rolę, jaką może odegrać w produkcji energii synteza termojądrowa. Opisano zjawisko syntezy termojądrowej oraz pokazano w jaki sposób można ją przeprowadzić w warunkach ziemskich na urządzeniu tokamak. Omówiono stan i perspektywy rozwoju reaktorów termojądrowych opartych na układach typu tokamak. W podsumowaniu wymieniono najważniejsze wady i zalety tego sposobu produkcji energii.
EN
The future of thermonuclear fusion in global energy production is presented in the paper. The phenomena of fusion is described and it is shown how the fusion can be conducted on tokamak devices. The state and prospects of development of the fusion reactor based on the tokamak-type systems are presented. In summary, major advantages and disadvantages of this method of energy production has been discussed.
PL
W artykule przedstawiono poligon badawczy systemów ochrony odgromowej należący do Politechniki Rzeszowskiej. Przeprowadzono badania rozpływu prądów udarowych w urządzeniu piorunochronnym obiektu budowlanego i dołączonej instalacji. W badaniach wykorzystano mobilny generator udarów prądowych i oryginalny system pomiarowy. Uzyskane wyniki potwierdzają rejestracje dokonane na Florydzie z wykorzystaniem wyładowań atmosferycznych prowokowanych. Kształty fal prądowych nie są jednakowe w różnych miejscach badanego układu i zależą od parametrów częstotliwościowych poszczególnych elementów instalacji, natomiast efektywność odprowadzania prądu piorunowego do ziemi przez urządzenie piorunochronne zależy od relacji między wartościami impedancji uziemienia obiektu budowlanego i uziemienia najbliższej stacji transformatorowej.
EN
The paper presents a new test site of lightning protection systems belonging to the Rzeszow University of Technology. Analysis of impulse current distribution in the lightning protection system and the connected installations has been conducted. An impulse current generator was used together with the original measurement system during experimental tests. Obtained results confirm registrations made in Florida with usage of triggered lightning experiments. Current waveforms are not the same in lightning protection system and are influenced by frequency dependent parameters of different parts of the installation. The effectiveness of lightning protection system depends on the relation between the amount of impedances of the local grounding system and the grounding system of the transformer station.
7
EN
This paper presents results of the recent plasma-focus (PF) experiments carried out with PF facilities, which was operated at energies ranging from 0.5 MJ to about 1 MJ. Particular attention has been paid to pinch evolution, the emission of pulsed X-ray, fast electron beams, and fusion produced neutrons. Some theoretical models of the initial breakdown, which occurs at the insulator surface, are compared. It is pointed out that modeling of the breakdown is sensitive to kinetics of ionization processes and transport coefficients. Progress in experimental studies of the axial acceleration phase is unsatisfactory. Important experimental data have been collected, but new measurements are still needed. For the radial collapse phase, it was shown that the MHD modeling is efficient until the maximum compression, but plasma instabilities require more sophisticated approaches. The pinch phase was investigated by means of different diagnostics. Fusion neutron yields were measured in different experiments, but some discrepancies in scaling must still be explained. The conclusions concern directions for further studies and optimization of large-scale high-current PF facilities.
EN
A review of results on the design and operation of the new efficient Dense Plasma Focus device PF-6 of medium size (transportable) having bank energy of ca. 7 kJ and possessing a long lifetime is presented. New data on the interaction of the pulsed fast ion beams and dense plasma streams generated at this apparatus with various materials are given. These results are compared with the analogous information received at the biggest facility PF-1000. It is shown that it is possible to have about the same power flux density (in the range of 105 109 W/cm2) in both devices however in different areas. Doses of soft X-rays produced by the device within the resists for the goals of microlithography and micromachining appear to be several times less that it is with the conventional X-ray tube. In biological application of this device, medium- and hard-energy X-rays are exploited in the field of radioenzymology. It was found that the necessary dose producing activation/inactivation of enzymes can be by several orders of magnitude lower if used at a high-power flux density in comparison with those received with isotope sources. In medicine, short-life isotope production for the goals of the positron emission tomography (medicine diagnostics) is possible by means of the fast ions generated within DPF. All these experiments are discussed in the framework of pulsed radiation physics and chemistry in its perfect sense thereto the criteria are formulated.
EN
A review of some experimental results obtained using the dense plasma focus (DPF) device PF-1000 is presented. The copper Ka1,2 radiation line generated by DPF in the case of device anode made of copper was the main object of this study. The predominance of this characteristic radiation over other kinds of radiation in the DPF X-ray spectrum is shown. A brief description of a new DPF 6.0 device as well as a radioenzymology experiment carried out within this device is presented.
EN
Non-thermal plasma of pulsed dielectric-barrier discharge (PDBD) was used for the decomposition of tetrachloromethane. The study was carried out using air or oxygen as carrier gas. The effect of the initial concentration of CCl4, flow rate of gas mixture and presence of the packing in the discharge gap on conversion rate of CCl4 was studied. The pulsed dielectric-barrier discharge combined with the packing of TiO2, Pt/SiO2 or SiO2 (quartz glass) has been applied for tetrachloromethane conversion. It has been concluded that the granular packing in the discharge gap increases the conversion rate of tetrachloromethane.
PL
Wymienioną w tytule cienką warstwę osadzano z mieszaniny gazowej helu, tlenu i tetraetoksysilanu (TEOS) (tabela 1) w aparaturze przedstawionej schematycznie na rys. 1-3. Proces prowadzono pod ciśnieniem atmosferycznym bez podgrzewania podłoża poliwęglanowego (PC) w postaci płytek. Zbadano wpływ parametrów procesu, mianowicie sposobu ułożenia płytek PC w reaktorze (rys. 7, 9 i 10), składu gazu plazmotwórczego (rys. 8) oraz natężenia prądu w pojedynczym impulsie wyładowania na szybkość osadzania. Szybkość ta rosła od 3,4 do 40,8 nm/min wraz ze wzrostem natężenia prądu w pojedynczym impulsie od 50 do 100 A. Stwierdzono, że w procesie tworzenia cienkiej warstwy konieczna jest obecność tlenu w gazach plazmotwórczych, przy czym nadmiar tlenu powoduje zmniejszenie szybkości osadzania z 14,9 do 6,0 nm/min gdy stężenie tlenu wzrasta od 5 do 20 % obj. (tabela 2). Budowę chemiczną oraz morfologię osadzonych warstw scharakteryzowano metodami FT-IR (rys. 4), AFM (mikroskopia siła atomowych, rys. 5) oraz SEM (rys. 6). Cienka warstwa składała się z następujących pierwiastków: Si, C, O oraz H i charakteryzowała się gładkością, a także przezroczystością.
EN
The process of thin organo-silica film deposition on polycarbonate in pulsed dielectric barrier discharge was studied. Thin film was deposited from the gas mixture comprising helium, oxygen and tetraethoxysilane under atmospheric pressure without pre-heating of polycarbonate plate. Influences of process parameters, namely the current of single pulse of discharge, PC plate arrangement and position, and plasma-generating gas composition on the deposition rate were investigated. Deposition rate increased from 3.4 to 40.8 nm/min when the current of single pulse increased from 50 to 100 A. The presence of oxygen in plasma-generating gas was necessary to thin organosilicon film forming, but the excess of O2 concentration caused decreasing of film deposition rate, for example: deposition rate was 14.9 or 6.0 nm/min when concentration of O2 was changed from 5 to 20 % by vol. In the films, the following elementaly composition (Si, C, O, H) and morphology of deposited films were characterized.
12
EN
Organo-silicon layers were deposited on polycarbonates (PC) substrates from the gas phase by using pulsed dielectric barrier discharge. Very short (~ 20 ns) pulses of high power discharge (-0.4 MW) were applied. The process was carried out under atmospheric pressure in a helium-oxygen plasma. Tetraethoxysilane (TEOS) vapours were used as a source of silicon. The surface morphology, composition and thickness of the layers were studied by means of AFM/TM, FTIR and SEM. The organo-silicon layers were found to be transparent, smooth and uniform over the whole substrate surface. The amplitude of the deviations from surface uniformity did not exceed 30 nm. The thickness of the deposited layers was of the order of ~2 |j.m.
PL
W wyniku przeprowadzonych badań odporności na wyładowania piorunowe potwierdza się, że wszystkie rozwiązania ochrony odgromowej przedstawionych do oceny statków powietrznych spełniają wymagania odnośnych rodziałów przepisów FAR lub JAR.
EN
As a result of worked out investigations of the resistance against the lightning discharge there is proved that all solutions of lightning protection presented for the assessment of the aircraft fulfil reguirements of respective sections of FAR or JAR regulations.
PL
Modelowy układ, składający się z wyizolowanej typowej samolotowej belki podskrzydłowej i podwieszonej pod nią bomby lotniczej, poddano działaniu impulsu prądu, symulującego uderzenie pioruna. W artykule przedstawiono wyniki pomiarów natężenia prądu indukowanego w obejmującej spłonkę gałęzi obwodu elektrycznego mechanizmu podawania impulsu bomby. Przedstawiono również wyniki pomiarów energii progowej zadziałania spłonki dla impulsów pobudzających o różnych czasach trwania. Energia, wydzielana w spłonce w czasie trwania impulsu piorunowego, przewyższa energię progową o kilka rzędów wielkości, co powoduje konieczność opracowania odpowiednich urządzeń zabezpieczających.
15
Content available Recent progress in 1 MJ Plasma-Focus research
EN
The paper reports on actual operational characteristics of the PF-1000 facility and it presents results of the first neutron experiments performed with a new set of large Mather-type electrodes, which were designed for shots up to 1000 kJ. Dynamics of a current-sheath was studied by means of two high-speed streak cameras and a two-frame camera. The last one was used for the side-on observation of the pinch column. The high-speed streak pictures were taken side-on behind slits oriented in the radial or axial direction. On the basis of the pictures taken behind the radial slit, average values of the radial compression and expansion velocities were estimated. Time-resolved X-ray signals were measured with PIN diodes covered by different filters, and they were compared with other traces (voltage waveforms, dI/dt signals, and neutron-induced pulses) in order to determine their correlation. The total neutron yield (Ytot), i.e. the number of neutrons produced during a single discharge and emitted in various directions, was measured by means of several silver-activation detectors placed at different angles around the PF-1000 experimental chamber.
first rewind previous Strona / 1 next fast forward last