The development of the interphase structure of polymer nanocomposites provides them with tribological properties difficult to obtain in traditional microfiller composites and microhybrid composites. In material solutions, it is preferable to modify the parameters of the material in order to obtain properties that are as close to the hard tissues of the teeth as possible. The aim of the study is to compare the wear resistance of new light-cured nanocomposites and to analyse the surface layer and structure before and after the wear process. Recently developed modern materials were selected for the study. In nanocomposites, G-aenial, G-aenial X FLO, and Essentia, an optimal structure was found in SEM images before and after wear, as well as low resistance to sliding friction and resistance to tribological wear. All tested composites were characterized by suitable properties for clinical applications.
PL
Rozwinięcie struktury międzyfazowej nanokompozytów polimerowych nadaje im właściwości tribologiczne trudne do uzyskania w tradycyjnych kompozytach z mikrowypełniaczami i kompozytach mikrohybrydowych. W rozwiązaniach materiałowych preferuje się taką modyfikację parametrów tworzywa, aby uzyskać właściwości najbardziej zbliżone do tkanek twardych zębów. Celem pracy jest porównawcza ocena odporności na zużycie nowych nanokompozytów utwardzanych światłem oraz analiza warstwy wierzchniej i struktury przed i po procesie zużycia. Do badań wytypowano nowoczesne materiały, które zostały opracowane w ostatnim czasie. W nanokompozytach G-aenial, G-aenial X FLO i Essentia stwierdzono w obrazach SEM jednorodną strukturę na etapie opracowania klinicznego oraz strukturę pozbawioną wyraźnych zarysowań, złuszczeń i wykruszeń po procesie zużycia, a także małe opory ruchu w tarciu ślizgowym i odporność na zużycie tribologiczne. Wszystkie badane kompozyty charakteryzowały się odpowiednimi właściwościami do zastosowań klinicznych.
The clinical functionality of the prosthesis structure consists of creating the most convenient conditions without any traumatic effects of chewing forces on the substrate and adapting it to the individual biomechanical exclusions of the stomatognathic system (SS). When transferring functional loads, the optimization of tribological features and the ability to absorb energy is an important design and material parameter. The aim is to evaluate acrylic plastics intended for prostheses in terms of resistance to wear and resistance to movement in sliding contact within the environment of artificial saliva and their ability to absorb energy. Based on the analysis of the test results, it can be pointed out that Vertex is a good material for partial and complete dentures. Villacryl demonstrated similar properties, with Probase and Probase O being slightly worse. The appropriate mechanical parameters of the materials used in the prosthesis allow the production of thin plates that accurately reproduce the prosthetic substrate and improve the patient’s comfort of use through such a fit.
PL
Funkcjonalność kliniczna konstrukcji protezy polega na stworzeniu najdogodniejszych warunków bezurazowego oddziaływania sił żucia na podłoże oraz dostosowania jej do indywidualnych wymuszeń biomechanicznych US. Przy przekazywaniu obciążeń czynnościowych istotnym parametrem konstrukcyjno-materiałowym jest optymalizacja cech tribologicznych oraz zdolność do pochłaniania energii. Celem jest ocena tworzyw akrylowych przeznaczonych na protezy w zakresie odporności na zużycie i oporów ruchu w kontakcie ślizgowym w środowisku sztucznej śliny oraz ich zdolności do pochłaniania energii. Na podstawie analizy wyników badań można wskazać, że Vertex jest dobrym materiałem do wykonywania protez częściowych i całkowitych. Zbliżone do niego właściwości posiadał Villacryl, a nieco gorsze Probase i Probase O. Odpowiednie parametry mechaniczne materiałów stosowanych na protezy pozwalają na wykonanie cienkich płyt, które dokładnie odwzorowują podłoże protetyczne i poprzez takie dopasowanie poprawiają pacjentowi komfort użytkowania.
Prosthetic crowns reproduce the damaged hard structures of the patient’s own teeth and take over their natural functions, thus securing the correct reconstruction of the stomatognathic system. The aim is to evaluate the crowns for premolars and molars produced by casting, milling, and Selective Laser Melting technologies, in terms of the accuracy of reproducing the degree against the prosthetic pillar, the analysis of the surface layer structure of the step, and the micromechanical parameters of the alloy. The study material included CoCrMo alloy crowns. The conducted study allowed finding that the tightness of prosthetic crowns made using traditional casting technology as well as in SLM milling and technology is comparable and meets clinical requirements. Structural crown analyses confirmed the very good quality of the surface layer obtained with milling technology and SLM technology using the CAD/CAM method. SLM and digital milling allow the formation of precise and durable structures constituting the foundation of crowns in a time much shorter than the casting process.
PL
Korony protetyczne odtwarzają uszkodzone twarde struktury zębów własnych pacjenta, przejmują ich naturalne funkcje i w ten sposób zabezpieczają prawidłową odbudowę układu stomatognatycznego. Celem jest ocena koron na zęby przedtrzonowe i trzonowe wytwarzane technologią odlewania, frezowania oraz Selective Laser Melting, w zakresie: dokładności odwzorowania stopnia względem filara protetycznego, analizy struktury warstwy wierzchniej stopnia, parametrów mikromechanicznych stopu. Materiałem badań były korony ze stopu CoCrMo. Przeprowadzone badania pozwoliły stwierdzić, że szczelność koron protetycznych wykonanych w technologii tradycyjnego odlewania oraz w technologii frezowania i technologii SLM jest porównywalna i spełnia wymogi kliniczne. Analizy strukturalne koron potwierdziły bardzo dobrą jakość warstwy wierzchniej uzyskiwanej w technologii frezowania oraz w technologii SLM metodą CAD/CAM. SLM i frezowanie metodą cyfrową pozwalają na wytworzenie precyzyjnych i wytrzymałych konstrukcji stanowiących podbudowy koron w czasie znacznie krótszym niż proces odlewniczy.
The aim of the study was to conduct strength analysis of a knee joint in order to experimentally determine the destructive fatigue loading under the conditions of cyclic compression. Animal joints were used as the study material. They were periodically subjected to variable axial loading. The degree of joint deformity and damage to articular surfaces and menisci were globally determined after isolation of the joint structures. The application of the variant of axial loading without slip and rolling results in the rupture of the medial meniscus, which is an important biotribological structure. Fatigue testing of the joints allowed for the determination of the parameters of biomechanical extortions, which lead to the loss of normal lubrication conditions and the degradation of the meniscus and cartilage structures on the femoral condyles.
PL
Celem jest analiza wytrzymałościowa w stawie kolanowym, która pozwala na eksperymentalne wyznaczenie niszczącego obciążenia zmęczeniowego w warunkach cyklicznego ściskania. Materiałem badań były stawy zwierzęce. Poddano je okresowo zmiennym obciążeniom osiowym. Oceniano globalnie stopień deformacji stawu oraz stopień uszkodzeń powierzchni stawowych i łąkotek po separacji struktur stawowych. Wariant obciążeń osiowych bez realizacji poślizgu i przetaczania się prowadzi do pękania łąkotki przyśrodkowej, która stanowi odpowiedzialną strukturę biotribologiczną. Badania zmęczeniowe stawów pozwoliły przybliżyć parametry wymuszeń biomechanicznych, które powodują utratę prawidłowych warunków smarowania i degradację struktur łąkotek oraz chrząstki na kłykciach kości udowej.
Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.
The functionality of a prosthesis is determined by clinical procedures, the manufacturing technology applied, the material used and its strength parameters. The aim of the paper is to evaluate the static strength and fatigue strength of acrylic construction materials directly after the process of polymerisation and for aged materials. It has been confirmed that the deformation speed of the tested materials has an evident impact on their mechanical characteristics.With greater deformation speed, a consistent increase in the material elasticity was observed in static compression tests, which was accompanied by a reduction in engineering stresses at the final stage of deformation. The greatest fatigue strength was observed for Vertex. It was by about 33% greater than the strength of Villacryl – the material that has the lowest fatigue properties. The resistance of acrylic polymers to cyclic loading applied with the frequency of 1 Hz may become an indication for the selection of the material to be used in the clinical procedures in which a patient is provided with full dentures.
Physiological abrasion of teeth is a process of gradual loss of the hard tissue of opposite teeth resulting from age-related natural dental wear. In abrasion, the cusps and their slopes in the jaw and the mandible become flattened due to the mechanical load applied. The aim of this paper is to carry out a tribological and microstructural evaluation of modern composite materials used to reconstruct the teeth in the lateral part of the dental arch. Five light-cured composite materials were selected for tests. The tests involved the coefficient of friction and resistance to wear in a sliding contact in the presence of artificial saliva and the microstructure of the external surface of samples before the wear process and in the wear-related damaged area. The test method applied, which combines a biomechanical analysis of resistance to wear and the analysis of the microstructure before the wear process and in the wear-related damaged area, makes it possible to evaluate the tribological properties of composite materials used to reconstruct teeth in the lateral part of the dental arch.
PL
Fizjologiczne starcie zębów jest to proces stopniowej utraty twardych tkanek zębów przeciwstawnych w wyniku naturalnego zużycia postępującego z wiekiem. Starcie to polega na jednoczesnym spłaszczaniu guzków i ich stoków w zębach szczęki i żuchwy w warunkach obciążeń biomechanicznych. Celem pracy jest ocena tribologiczna i mikrostrukturalna nowoczesnych materiałów kompozytowych stosowanych do odbudowy ubytków w bocznym odcinku łuku zębowego. Do badań wybrano 5 materiałów kompozytowych utwardzanych światłem. Przeprowadzono badania współczynnika tarcia i odporności na zużycie w kontakcie ślizgowym, w obecności sztucznej śliny oraz badania mikrostrukturalne warstwy wierzchniej próbek przed procesem zużycia oraz w strefie skazy zużyciowej. Zastosowana metoda badań łącząca biomechaniczną analizę odporności na zużycie z analizą mikrostruktury przed procesem zużycia oraz w skazie zużyciowej pozwala na ocenę właściwości tribologicznych materiałów kompozytowych do odbudowy zębów w bocznym odcinku łuku.
Hip replacement surgery, by introducing a specific replacement head on the stem and cup, completely changes the conditions of co-operation typical for the biological correct pair. The clinical selection of endoprosthesis, apart from other conditionings, involves a dilemma between the choice of a rigid tribological node and the selection of a susceptible bearing cushioning the locomotive loads. The aim of the study is to evaluate the coefficient of friction and wear resistance of materials used for sliding contact in the endoprostheses of hip joints. On the basis of the conducted tests, it can be stated that, in the selection of material for cups of endoprosthesis, the wear resistance is important, and the coefficient of friction in contact head and cup in the prosthesis is less important. The presence of significant disproportions between the two parameters of the tribological process proves that the biomaterial is less useful on the cup. In the assessment of cooperation in the endoprosthesis, simulations of the contact of structural elements are useful, because, on that basis, in the correlation with tribological parameters, one can make conclusions about the distribution of stresses and displacements that may determine the lifetime of the implant.
PL
Zabieg alloplastyki stawu biodrowego poprzez wprowadzenie określonej zamiennej głowy na trzpieniu i panewki zmienia całkowicie warunki współpracy charakterystyczne dla biologicznej prawidłowej pary. Kliniczny dobór endoprotezy, oprócz innych uwarunkowań, wiąże się z dylematem pomiędzy wyborem sztywnego węzła tribologicznego a wyborem biołożyska podatnego, amortyzującego obciążenia lokomocyjne. Celem pracy jest ocena współczynnika tarcia i odporności na zużycie materiałów stosowanych na panewki do kontaktu ślizgowego w endoprotezach stawu biodrowego. Na podstawie przeprowadzonych badań można stwierdzić, że w doborze materiału na panewkę endoprotezy ważna jest odporność na zużycie ścierne, a nieco mniejsze znaczenie ma współczynnik tarcia w kontakcie z głową endoprotezy. Występowanie znacznych dysproporcji między tymi dwoma parametrami procesu tribologicznego świadczy o słabszej przydatności biomateriału na panewki endoprotez. W ocenie współpracy w endoprotezie przydatne są symulacje kontaktu elementów konstrukcyjnych, ponieważ na ich podstawie, w korelacji z parametrami tribologicznymi, można wnioskować o rozkładach naprężeń i przemieszczeń, które będą decydować o żywotności implantu.
The latest method for creating denture replenishment in CAD / CAM systems is Direct Metal Laser Sintering (DMLS) technology. With the use of DMLS, prosthodontics, implant prosthetics, and facial-cranialjaw surgery adapted to individual patient conditions can be realized. The aim is to evaluate the strength, microstructure, and tribological properties of Ti6Al4V and CoCrMo alloys obtained from DMLS technology in the aspect of therapeutic constructions. The conducted tests show that, in the DMLS technology, as compared to milling technology preceded by casting and forging or pressed powder and sintering, for the same percentage composition of elements, the micromechanical properties, microstructural and tribological change. This procedure, from which constructions for various dental applications are obtained, is the new technology preferred for making permanent restorations faced with ceramics, producing intravascular implants, and implants of the temporomandibular joint. It can be an alternative to conventional cast-based methods and CAD / CAM based milling.
PL
Najnowszą metodą tworzenia uzupełnień stomatologicznych w systemie CAD/CAM jest technologia Direct Metal Laser Sintering (DMLS). Z wykorzystaniem DMLS można realizować wykonanie konstrukcji protetyki, implantoprotetyki oraz chirurgii twarzowo-czaszkowo-szczękowej dostosowanej do indywidualnych warunków pacjenta. Celem jest ocena parametrów wytrzymałościowych, mikrostruktury i właściwości tribologicznych stopów Ti6Al4V oraz CoCrMo uzyskanych w technologii DMLS w aspekcie zastosowania na konstrukcje terapeutyczne. Przeprowadzone badania wskazują, że w technologii DMLS, w porównaniu z technologią frezowania poprzedzoną procesami odlewania i kucia lub prasowania proszku i spiekania, dla tego samego składu procentowego pierwiastków, zmieniają się właściwości mikromechaniczne, mikrostrukturalne i tribologiczne. Procedura ta, w wyniku której uzyskuje się konstrukcje dla różnych aplikacji stomatologicznych – jest nową technologią preferowaną do wykonawstwa uzupełnień stałych licowanych ceramiką, do wytwarzania wszczepów śródkostnych oraz implantów stawu skroniowo-żuchwowego. Może ona stanowić alternatywę dla klasycznych metod opartych na odlewnictwie oraz metod CAD/CAM opartych na frezowaniu.
This paper presents a preoperative hip reconstruction method with diagnosed osteoarthritis using Durom Hip Resurfacing System (DHRS). The method is based on selection and application of the resurfacing to the pelvis reconstructed on the basis of computed tomography. Quality and geometrical parameters of distinguished tissues have a fundamental significance for locating and positioning the acetabular and femoral components. The application precedes the measurements of anatomical structures on a complex numerical model. The developed procedure enables functional selection of endo-prosthesis and its positioning in such a way that it secures geometric parameters within the bone bed and the depth , inclination angles and ante-version of the acetabular component, the neck-shaft angle and ante-torsion angle of the neck of the femoral bone, and reconstruction of the biomechanical axis of the limb and the physiological point of rotation in the implanted joint. Proper biomechanics of the bone-joint complex of the lower limb is determined by correlation of anatomical-geometrical parameters of the acetabular component and parameters of the femoral bone.
The optical methods of coordinate measuring are a tool that have been more and more frequently used in biometrological applications, due to their advantages. The object of this paper is to set the accuracy of modelling solids of revolution whose shapes and measurements find their application in medical diagnostics with the use of three measurement systems employing laser and structured light. The carry out the studies, a coordinate measuring machine LK CMM with LC60Dx laser scanner, a coordinate measuring Romer Absolute Arm 7320SI with HP-L-20.8 laser scanner and an optical Scan 3D Qualify scanner were used. The use of coordinate technique to analyze the shape of the model solids allowed for the comparison of accuracy of optical methods with reference to standards digitally modelled based in measurements made by CMM Leitz PMM 12106. The most preferable contactless system to render the shape of solids of revolution is the LK CMM with LC60Dx laser scanner.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Purpose: The aim of this study is to generate a global digital model of treatment, analysis of stress distribution and displacements: in a construction of the bracket, in the incisor with bonded bracket, in tissues of the incisor, in a periodontal membrane and in an alveolus. Methods: An orthodontic therapy was provided with a three-dimensional model of a unique Cannon Ultra bracket. The placement of the bracket to the incisor was provided according to clinical standards. Composite material was placed between the rough surface of the bracket's base and labial incisor surface – which, in a digital model, resulted in contact without displacement. The bracket was loaded. An orthodontic arch wire was free to move in a wing slot of the bracket. For simplification, a force vector was parallel to the longitudinal axis of the incisor. A clamper was set on the surface of the cortical bone of the alveolus. The model was divided into a finite number of tetrahedral elements. To calculate the distribution of stress Ansys Workbench software was used. Results: The stress values indicate that there were no tissue overloaded areas. The stress distribution was regular in the periodontal ligament. Slight movements were observed with maximal values in the area of apex. Conclusions: This study simulation proves that tissues surrounding the tooth were influ-enced mechanically by the force loaded on the bracket. [...]
Purpose: The aim of the present paper was a question of structural identification and evaluation of strength parameters of Titanium (Ticp – grade 2) and its alloy (Ti6Al4V) which are used to serve as a base for those permanent prosthetic supplements which are later manufactured employing CAD/CAM systems. Methods: Microstructural tests of Ticp and Ti6Al4V were conducted using an optical microscope as well as a scanning microscope. Hardness was measured with the Vickers method. Micromechanical properties of samples: microhardness and Young’s modulus value, were measured with the Oliver and Pharr method. Results: Based on studies using optical microscopy it was observed that the Ticp from the milling technology had a single phase, granular microstructure. The Ti64 alloy had a two-phase, fine-grained microstructure with an acicular-lamellar character. The results of scanning tests show that titanium Ticp had a single phase structure. On its grain there was visible acicular martensite. The structure of the two phase Ti64 alloy consists of a β matrix as well as released α phase deposits in the shape of extended needles. Micromechanical tests demonstrated that the alloy of Ti64 in both methods showed twice as high the microhardness as Ticp. In studies of Young’s modulus of Ti64 alloy DMLS technology have lower value than titanium milling technology. Conclusions: According to the results obtained, the following conclusion has been drawn: when strength aspect is discussed, the DMLS method is a preferred one in manufacturing load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
Najnowszą technologią wykonywania konstrukcji protetycznych jest DLMS. Celem badań jest ocena tej technologii oraz technologii odlewania pod względem mikrostruktury oraz twardości stopu CoCrMo. Materiałem badań były próbki ze stopu SP2 wykonane technologią DLMS. Grupę kontrolną stanowiły próbki z Remanium GM 800+ z odlewania. Badania strukturalne wykonano na mikroskopie skaningowym. Pomiary twardości przeprowadzono metodą Vickersa. SP2 wykazał jednorodną budowę i skład chemiczny oraz twardość 629 HV. W Remanium GM 800+ zaobserwowano mikrosegregację dendrytyczną oraz porowatości, twardość wynosiła 513 HV. Można stwierdzić, że DMLS w aspekcie mikrostruktury i twardości jest technologią preferowaną na indywidualne konstrukcje dla protetyki.
Modyfikacje konstrukcyjne silnika, wymagania eksploatacyjne oraz ochrona środowiska wymuszają zróżnicowane parametry samochodowych olejów silnikowych w obszarze właściwości reologicznych i odporności na zużycie. Celem pracy jest testowa metoda oceny jakości olejów silnikowych na podstawie badań lepkości i odporności na zużycie węzłów ślizgowych. Materiałem badań były handlowe oleje mineralne, półsyntetyczne i syntetyczne – wielosezonowe, przynależne do różnych klas lepkościowych i jakościowych. Wyznaczono dla nich charakterystyki lepkości z wykorzystaniem reometru rotacyjnego oraz parametry odporności na zużycie na maszynie czterokulowej. Przeprowadzone badania pozwoliły na opracowanie metody porównującej oleje różnych klas lepkościowych.
16
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Celem opracowania była ocena in vitro szczelności koron ze stopu Co-Cr-Mo na zęby przedtrzonowe i trzonowe wykonanych w trzech technologiach: odlewania, frezowania i stapiania laserowego. Dla porównania dopasowania koron do filarów protetycznych stanowiących modele referencyjne wykorzystano skanowanie światłem strukturalnym i modelowanie w programie Geomagic Qualify 12. Badania pozwoliły stwierdzić, że szczelność koron protetycznych wykonanych w badanych technologiach jest porównywalna i spełnia wymogi kliniczne.
EN
The aim of the study was to assess the in vitro tightness crown alloy Co-Cr-Mo on the premolars and molars made in three technologies: casting, milling and laser melting. For comparison fitting crowns to the pillars of prosthetic on which the reference models used structured light scanning and modeling in the Geomagic Qualify 12. The study revealed that the tightness of the prosthetic crowns made in the tested technologies is comparable and meets the requirements of the clinical.
17
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono aplikację wzorców kulowych oraz wzorców typu Ball Bar do oceny odwzorowania przy obrazowaniu CT medycznej. Celem jest ocena wybranych procedur dokładności odwzorowania kształtu i wymiarów z zastosowaniem certyfikowanych wzorców oraz zaproponowanie parametrów metrologicznych umożliwiających porównanie urządzeń diagnostycznych pod kątem aplikacji pomiarowych. Błędy odwzorowania geometrii mogą być identyfikowane na podstawie systemów kontrolnych wykorzystywanych w CT przemysłowej.
EN
The paper presents the application patterns of ball and patterns of the Ball Bar type to evaluate mapping with medical CT imaging. The aim is to evaluation the selected procedures for assessing the accuracy of mapping shape and dimensions of the use of certified standards and proposing metrological parameters for the comparison of diagnostic equipment for measurement applications. Geometry mapping errors can be identified on the basis of the control systems used in industrial CT.
18
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono przedzabiegową metodę rekonstrukcji stawu biodrowego z rozpoznaną chzs z zastosowaniem DHRS. Metoda zasadza się na doborze i aplikacji endoprotezy powierzchniowej do obręczy miednicy odtworzonej na podstawie CT. Wirtualną aplikację poprzedzają pomiary struktur anatomicznych. Opracowana procedura pozwala na funkcjonalny dobór komponenty panewkowej i udowej do indywidualnych warunków pacjenta.
EN
This paper presents the preoperative hip reconstruction method with diagnosed OA using DHRS. The method is based on the selection and application of the resurfacing to the pelvis reconstructed on the basis of CT. The virtual application precedes the measurements of anatomical structures. The developed procedure allows for functional selection of the acetabular component and the femoral component to the individual conditions of the patient.
19
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Laserowe spiekanie proszków metali (DMLS) jest nową technologią otrzymywania konstrukcji w procedurze CAD/CAM. Celem była identyfikacja strukturalna i wyznaczenie parametrów wytrzymałościowych stopu kobaltu na stałe uzupełnienia protetyczne wykonywane w dwóch technologiach. Materiałem badań był stop Co-Cr-Mo, z którego uzyskano próbki w technologii odlewania oraz w technologii DMLS. Stwierdzono, że DMLS jest technologią preferowaną do wykonawstwa konstrukcji dla protetyki i może stanowić alternatywę dla tradycyjnej metody odlewania.
EN
Direct Metal Laser Sintering (DMLS) is a new technology for obtaining reconstruction in the CAD / CAM procedure. The aim was to identify the structural and determination of strength parameters of cobalt alloy intended for fixed prosthetic restorations. carried out in two technologies. Test material was a Co-Cr-Mo alloy, from which the sample were obtained in a casting technology and DMLS technology. It was found that the DMLS is preferred technology for manufacturing reconstruction for prosthetics and can be an alternative to the traditional method of casting.
20
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Celem opracowania jest wyznaczenie dokładności odwzorowania modelowych brył obrotowych, których kształty i wymiary mają zastosowanie w diagnostyce medycznej, z wykorzystaniem trzech systemów pomiarowych ze światłem laserowym i strukturalnym. Zastosowanie techniki współrzędnościowej do analizy kształtu wzorców pozwoliło na porównanie systemów oraz wskazanie współrzędnościowej maszyny pomiarowej z kamerą laserową, jako najbardziej preferowaną do odwzorowania brył obrotowych.
EN
Aim of the study is to determine the accuracy of the mapping model of solids of revolution, whose shapes and sizes are used in medical diagnostics, using three measurement systems with laser light and structural. The use of coordinate technique for the analysis of the shape of patterns allowed the comparison of systems and an indication of coordinate measuring machine with laser camera, as the most preferred for mapping solids of revolution.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.