Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Pharmaceutical pollutants have been detected in many countries in surface and ground water after treatment in wastewater treatment plants. The presented studies concern the photocatalytic removal of one of SSRI antidepressants - sertraline from water using TiO2  photocatalyst. The process was conducted using two laboratory installations with periodic and flow reactors. Two forms of TiO2  was used in the photocatalytic reactions: suspended and supported onto a glass fabric. The studies shown that with increasing initial concentration of pharmaceutical, photoactivity decreases. For the initial concentration of 0.025 g/dm3 , the best results – 94% removal – was achieved for the process conducted in the periodic reactor with TiO2  supported onto a glass fabric.
EN
The purpose of this study is to form and test inseparable tight joints, commonly used in the construction of heat exchangers, by crimping operation on designed prototype stand. Crimped joints are made by tools in form of cones with two types of shapes, each of the designed tools have got identical forming angle. This study uses two types of connecting blocks and plates, differing in diameters of hole and flange. Elaboration contains a case study of joints being made by the stand, which in addition to the crimping operations for some cases were glued or brazed. The article presents the features of the formed joints, by examining them by destructive testing: Micrography, tensile strength test, and non-destructive testing: Leakage test. The examined elements have been made of aluminum 6060, which is well suited to indirect or direct operations of forming joints for all kinds of coolers or condensers. Elaborated tests and studies in this study allowed to state, that joining the connection block to plate with the small diameter, was more energy-consuming than in sample sets with bigger diameter, use of glue increasing the strength of the joints by 20%, significant strength increase can be obtained after mechanical clinching with brazing operation or modification of geometrical shape of the jaws.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.