The paper presents a method for optimal design of premium efficiency (IE3) squirrel-cage induction motor by utilizing radial scaling, axial scaling and rewinding of an existing 4 kW 4-pole high efficiency (IE2) motor. The scaling factors are defined for all parameters of the equivalent circuit and consider the influence of saturation on main and leakage inductances in all operating points. The optimal scaling factors are determined using Differential evolution optimization algorithm with minimum volume of iron stack defined as a cost function.
PL
W artykule zaprezentowano metodę optymalnego projektowania silnika indukcyjnego klatkowego w standardzie IE3 poprzez wykorzystanie skalowania promieniowego, osiowego oraz przezwojenia istniejącego silnika czterobiegunowego o mocy 4 kW w standardzie IE2. Współczynniki skalowania zdefiniowane zostały dla wszystkich parametrów obwodu zastępczego. Został rozważony wpływ nasycenia na indukcyjności: główną I rozproszenia we wszystkich punktach działania. Optymalne współczynniki skalowania są określone za pomocą algorytmu optymalizacyjnego ewolucji różniczkowej z minimalną objętością ferromagnetyka zdefiniowaną jako funkcja kosztu.
EN
The paper presents the method of selection, calculation and measurements of generator that is built into the new transformer test station. The three phase cylindrical synchronous generator 800 kVA, 200 Hz with special damper bars is most suitable to be used as a power supply for testing of single-phase and three-phase power transformers. The emphasis is on the analysis of the armature winding connection and sizing of the damper winding due to unsymmetrical load of a generator in the induced AC voltage test. The results indicate that D-connected generator with skewed stator slots is the best solution. Special temperature sensors were mounted in the rotor.
PL
W artykule przedstawiono metodę wyboru, obliczeń oraz pomiarów generator wbudowanego w nową transformatorową stację badawczą. Trójfazowy cylindryczny generator trójfazowy o mocy 800 kVA i częstotliwości 200 Hz ze specjalną szyną tłumiącą jest najdogodniejszy jako urządzenie zasilające do prób transformatorów jedno- i trójfazowych. Szczególną uwagę zwrócono na połączenie uzwojeń i wielkość uzwojenia tłumiącego z powodu niesymetrycznego obciążenia generatora w przypadku próby indukowanym napięciem. Wyniki wskazują na to, że generator z uzwojeniami połączonymi w trójkąt i skoszonymi żłobkami statora jest rozwiązaniem najlepszym. Specjalne czujniki temperatury zostały zamontowane w wirniku.
3
Content available remote Simplified model of transformer hysteresis curve
EN
A simplified model of transformer hysteresis curve utilized for calculation of core losses is presented. It incorporates eddy current losses and hysteresis losses into the same hysteresis curve thus simplifying a set of equations used for solving the magnetic circuit. The parameters of the hysteresis curve model are determined by evolutionary optimization which minimizes the difference between measured and calculated current waveforms from open-circuit test of a three-phase, three-leg transformer rated 400 V, 20.8 kVA. The core losses calculated from the surface area of hysteresis curves calculated for all three legs with supply voltage variation from zero to 10% above rated show a good match with measured losses.
PL
W artykule zaprezentowano uproszczony model krzywej histerezy w transformatorze, służący do obliczania strat w rdzeniu. Model zawiera zarówno straty wiroprądowe jak i straty histerezowe w jedną krzywą histerezy przez co upraszcza się układ równań używany w rozwiązywaniu obwodu magnetycznego. Parametry modelowanej krzywej histerezy określone są w procesie optymalizacji ewolucyjnej, która prowadzi do minimalizacji różnicy pomiędzy mierzoną i obliczaną wartością chwilową prądu próby stanu jałowego trójfazowego, trójkolumnowego transformatora o znamionach: 400 V i 20,8 kVA. Straty w rdzeniu obliczane przez całkowanie powierzchni pętli histerezy dla wszystkich trzech kolumn przy zasilaniu napięciem od zera do 10% wartości znamionowej pokazują dobrą zgodność z pomierzonymi stratami.
4
Content available remote Unsymmetrical load of a three-phase synchronous generator
EN
The selection of a three phase synchronous generator most suitable to be used as a power supply for testing of single-phase and threephase power transformers is described in the paper. The emphasis is on the analysis of the armature winding connection and sizing of the damper winding due to unsymmetrical load of a generator in the temperature rise test of single-phase transformers realized by the short-circuit method. The generator’s output voltage waveforms in the case of unskewed and skewed stator slots are analyzed. The results indicate that delta-connected generator with skewed stator slots is the best solution.
PL
W artykule opisano sposób doboru trójfazowego generator synchronicznego jako źródła zasilania dla testowanego transformatora jedno- i trójfazowego. Szczególny nacisk położono na uzwojenie twornika i rozmiary uzwojenia tłumiącego, ze względu na asymetrię obciążenia generatora przy wzroście temperatury w próbie zwarciowej transformatora jednofazowego. Wyniki analizy pokazują, że najlepszym rozwiązaniem jest generator ze skośnymi żłobkami stojana i uzwojeniach połączonych w trójkąt.