Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Within the context of the extended economic crisis, as a whole, gold and silver ores are now largely paid attention to by investors. In Romania, they have carried out, during the last years, a large number of researches regarding the prospection and planning of the exploitation of new Au-Ag ore deposits. The University of Petrosani, owing to its Laboratory of Rocks Mechanics, largely contributed to such research works, through the geomechanical analyses gathered from the mining areas of the “Golden Quadrangle” in the Apuseni Mountains. This paper presents the results of these geomechanical studies made in perimeters mentioned. The hereby paper displays conclusions determined by the geotechnical researches of the mining perimeter of Certej, performed in the Geomechanics Laboratory of the University of Petrosani, with a view to opening and exploiting the gold and silver deposit as part of a new mining project.
PL
W kontekście długotrwałego ekonomicznego kryzysu, uwagę inwestorów przykuwają głównie rudy złota i srebra. W Rumunii przeprowadzili oni w ciągu ostatnich lat wiele badań z zakresu prospekcji i planowania eksploatacji nowych złóż Au-Ag. Uniwersytet Petrosani, dzięki swojemu Laboratorium Mechaniki Skał, miał znaczny udział w tych badaniach, wykonując analizy geomechaniczne na próbach z rejonów górniczych „Złotego Czworokąta” w górach Apuseni. Niniejszy artykuł przedstawia wyniki badań geomechanicznych dotyczących ww. rejonu. Prezentuje wnioski z badań geotechników z rejonu Certej, przeprowadzonych w Laboratorium Geomechaniki Uniwersytetu Petrosani, z perspektywy rozpoczęcia nowego projektu eksploatacji złoża złota i srebra.
2
Content available remote Measurement of radon potential from soil using a special method of sampling
EN
Soil radon gas and/or its exhalation rate are used as indicators for some applications, such as uranium exploration, indoor radon concentration, seismic activity, location of subsurface faults, etc., and also in the studies where the main interest is the field verification of radon transport models. This work proposes a versatile method for the soil radon sampling using a special manner of pumping. The soil gas is passed through a columnof charcoal by using passive pumping. A plastic bottle filled with water is coupled to an activated charcoal column and the flow of water through an adjustable hole made at the bottom of bottle assures a controlled gas flow from the soil. The results obtained for the activity of activated charcoal are in the range of 20-40 kBq/m3, for a depth of approximately 0.8 m. The results obtained by this method were confirmed by simultaneous measurements using LUK 3C device for soil radon measurements. Possible applications for the estimation of radon soil potential are discussed.
3
Content available remote Membrane based on decyl-18-crown-6 for a potassium selective sensor
EN
Four kinds of 18-crown-6 derivatives were studied as ionophores in plasticized poly(vi-nyl chloride) (PVC) in order to obtain potassium selective membrane. The properties of the sensor were studied in detail. For the optimization of the selectivity toward K+ over Na+ the influence of the following factors was studied: nature and concentration of the ionophore; nature and concentration of the plasticizer and lipophilic salt addition. The potassium ion-selective membrane electrode was designed. The electrode has a fast and Nernstian response in the 1 x 10(-1)-2 x 10(-5) mol 1(-1) K+, after six months of continuous measurements. The change of pH in the range 2-10.5 does not affect the response of the electrode. The internal resistance of the electrode was measured. The electrode shows a good stability and can be used in the potentiometric determination.
PL
Badano cztery rodzaje pochodnych związku: 18-korona-6 jako jonofory w plastyfi-kowanym polichlorku winylu (PVC), w celu uzyskania membrany selektywnej względem jonów potasowych. Szczegółowo badano własności czujnika pomiarowego. W celu optymalizacji selektywności względem jonów K+ w porównaniu do jonów Na+ zbadano wpływ następujących parametrów: rodzaj i stężenie jonoforu, rodzaj i stężenie plasty-fikatora, oraz dodatek soli lipofilowej. Zaprojektowano jonoselektywną elektrodę membranową, selektywną względem jonów potasowych. Elektroda ma krótki czas odpowiedzi i nernstowską odpowiedź w granicach stężeń: 10(-1) x 10(-5) mol l(-1) K+ po sześciu miesiącach ciągłych pomiarów. Zmiana pH w granicach 2-10.5 nie wpływa na odpowiedź elektrody. Zmierzono wewnętrzną rezystancję elektrody. Elektrodę cechuje dobra trwałość i można ją używać do oznaczeń potencjometrycznych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.