State-of-the-art control systems often neglect the time-variant characteristics of power-electronic systems in favour of a time-averaged approach. In consequence, the resulting system is partly instable, thus not optimally controlled. The novel pole-restraining control (PRC) concept removes the inherent instability considerably improving dynamic behaviour. This enhancement is demonstrated at hand of a three-phase Active Front End (AFE). The essentials of the pole-restraining control approach are explained, the advanced transient behaviour is illustrated by comparison to other state-of-the-art control schemes.
PL
Analizując sterowanie przekształtników energo-elektronicznych ich czasowa zmienność jest często pomijana na rzecz podejścia uśredniającego. Powoduje to częściową niestabilność otrzymanego systemu, nie jest on więc sterowany optymalnie. Nowa metoda sterowania (PRC), ograniczającą bieguny systemu, usuwa wewnętrzną niestabilność, poprawiając dynamikę systemu. Poprawa ta jest pokazana w artykule na przykładzie sterowania przekształtnika trójfazowego (Active Front End - AFE). W artykule wyjaśniono istotę sterowania poprzez ograniczenie biegunów systemu, a procesy przejściowe zilustrowano porównaniem ich z wynikami otrzymanymi przy użyciu innych współczesnych metod sterowania.
EN
The dynamic control of n-phase converter-based Active Front Ends (AFE) supplying inverter-fed induction machines is a typical power electronic application. Modern converter topologies and new control strategies allow high dynamic of the grid-side converter. To reduce the demand on the converter control in case of load changes of the induction machines, the variation of mechanical power – represented by the active grid power in electrical domain – is predicted. Therefore an approximation of the transient torque response by a parameter-dependent fourth-order time-delay element of an induction machine controlled by Indirect Stator-Quantities Control (ISC) is presented. The prediction method improves the power factor regarding to power quality of the drive application and allows a leaner dimensioning of the used electronic devices.
PL
Sterowanie dynamiczne n-fazowym układem przekształtnikowym typu AFE (z ang. Active Front End) dla zasilania układów z silnikami indukcyjnymi jest typową aplikacją z dziedziny energoelektroniki. Nowe strategie sterowania zapewniają wysoką dynamikę przekształtnika sieciowego. W układzie sterowania zastosowano predykcję zmian mocy mechanicznej reprezentowanej przez moc czynną sieci. Zaprezentowano aproksymację stanów przejściowych odpowiedzi momentu za pomocą elementu czwartego rzędu z opóźnieniem zależnego od parametrów silnika indukcyjnego sterowanego metodą ISC (Indirect Stator-Quantities Control). Zastosowana metoda poprawia współczynnik mocy całego układu.