Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 45

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
1
Content available remote Magnetic field strength sensor
EN
In this paper a new kind of sensor for magnetic field strength measurement in soft materials by direct method has been presented. The sensor consists of induction coil and ferromagnetic electrodes. Its construction makes possible to measure the magnetic field strength directly at the sample surface. The principle of operation and construction of sensor were provided. Also, preliminary experimental study of the sensor was presented. The values of strength of magnetic field measured by the sensor were compared with the values obtained by means of Epstein frame. The obtained results showed that designed magnetic field strength sensor is adequate to test electrical steel.
PL
W artykule przedstawiono nowy rodzaj czujnika do pomiaru natężenia pola magnetycznego materiałów magnetycznie miękkich metodą bezpośrednią. Czujnik składa się z cewki indukcyjnej i elektrod ferromagnetycznych. Jego konstrukcja umożliwia pomiar natężenia pola magnetycznego bezpośrednio na powierzchni próbki. Przedstawiono zasadę działania i budowy czujnika oraz wyniki badań wstępnych. Wartości natężenia pola magnetycznego mierzone przez czujnik porównano z wartościami uzyskanymi za pomocą ramy Epsteina. Uzyskane wyniki wykazały, że zaprojektowany czujnik pola magnetycznego jest odpowiedni do badań blach elektrotechnicznych.
PL
W artykule, na podstawie dokonanego przeglądu literatury, przedstawiono istniejące problemy pomiaru natężenia pola magnetycznego metodą pośrednią i bezpośrednią w blachach elektrotech-nicznych oraz próby ich rozwiązania. Opisano czujniki składowej natężenia pola magnetycznego stosowane najczęściej do pomiaru natężenia pola magnetycznego w blachach elektrotechnicznych.
EN
The paper presents, based on a review of relevant literature, the existing problems of magnetic field strength measurements of electrical steel sheets by means of the indirect and direct methods. It also describes some attempts to solve these problems. The magnetic field strength sensors most widely used for testing electrical steel sheets are also discussed.
3
Content available remote Local magnetisation of a grain-oriented electrical steel sheet
EN
In the paper, the possibility of measuring fundamental magnetic properties of punched parts of electrical steels by means of nondestructive method and requirements for the measurement area of tested object resulting from its was discussed. Also, experimental results of local magnetisation distribution of the grain-oriented electrical steel sheets area with different width magnetised asymmetrically from one of its surfaces were shown.
PL
W artykule przedstawiono możliwości pomiaru podstawowych wielkości magnetycznych wykrojów blach elektrotechnicznych metodą nieniszczącą oraz wynikające stąd wymagania stawiane obszarowi pomiarowemu badanego obiektu. Przedstawiono również przykładowe wyniki pomiaru rozkładu indukcji na orientowanych blachach elektrotechnicznych o różnej szerokości.
PL
W artykule przedstawiono możliwości pomiaru podstawowych wielkości magnetycznych oraz wynikające stąd wymagania stawiane obszarowi pomiarowemu badanego obiektu. Przedyskutowano możliwości spełnienia wymagań jednorodnego magnesowania badanego obiektu pod kątem pomiaru właściwości magnetycznych metodą nieniszczącą. Przedstawiono również konkretne rozwiązanie układu probierczego dla ażurowanego, zamkniętego wykroju blachy elektrotechnicznej wchodzącego w skład pakietu stojana silnika małej mocy. Podano również przykładowe wyniki pomiarów wielkości magnetycznych charakteryzujących właściwości badanego fragmentu magnetowodu.
EN
The paper presents the possibility of measuring fundamental magnetic properties of punched parts of electrical steels by means of nondestructive method and requirements for the measurement area of tested object resulting from its. The possibility of meeting requirements of homogeneous magnetization of the tested object for measurements of magnetic properties by means of non-destructive method is also discussed. Also a specific solution for the both open and closed punched parts of electrical steels forming magnetic core of low-power motor stator is presented. The paper also provides examples of measurement results of the magnetic properties of punched part of electric motor core.
EN
The paper presents an integral sampling method which enables one to determine not only magnetization characteristics, but also loss at deep saturation magnetization. The peculiarities of the method, the obtained typical hysteresis loops and the calculated loss values are discussed.
PL
W artykule przedstawiono metodę próbkowania całkowego pozwalającą wyznaczyć nie tylko charakterystyki magnesowania ale również stratności w obszarze nasycenia magnetycznego. Przedyskutowano właściwości metody, otrzymane przykładowe przebiegi pętli histerezy oraz wyniki obliczonych wartości stratności.
6
Content available Kompensacja uogólnionej mocy biernej
PL
Uogólniona moc bierna jest określona przez powierzchnie pętli utworzonych przez charakterystyki prądowo napięciowe obiektów. Jest wielkością addytywną, zależy tylko od parametrów reaktancyjnych i jest zawsze równa zeru, jeśli energia elektryczna jest całkowicie rozpraszana w obiekcie. Uogólniona moc bierna jest także przydatna do poprawy współczynnika mocy. W artykule przedstawiono dowody, że jeśli uogólniona moc bierna zostanie skompensowana do zera, to przy niezmienionym napięciu, wartość skuteczna pobieranego przez obiekt prądu osiąga minimum, a współczynnik mocy wartość największą w danych warunkach pracy obiektu.
EN
Generalized reactive power is determined by the surface of the loop formed by the current-voltage characteristics of object. It is an additive quantity and depends only on the reactance parameters and is always equal to zero if the electricity is completely dissipated in the object. Its value is the basis for determining the parameters of the system to allow the desired improvement in power coefficient. The paper presents evidence that, if generalized reactive power is compensated to zero, then at a constant voltage, rms current drawn by the object reaches minimum, and power factor - the greatest value in working conditions of the object.
EN
In this paper distribution of demagnetizing field of a rectangular sample made of an anisotropic silicon electrical steel was determined analytically. The measuring windings were wound on the sample, which was placed in an homogenous external magnetic field in a coil. The distribution of the magnetic induction was measured and based on it demagnetizing field distribution was calculated.
PL
W artykule wyznaczono analitycznie rozkład pola odmagnesowującego prostokątnej anizotropowej krzemowej próbki blachy elektrotechnicznej. Uzwojenia pomiarowe nawinięto na próbkę, która została umieszczona w jednorodnym zewnętrznym polu magnetycznym w cewce. Zmierzono rozkład indukcji magnetycznej i na jego podstawie obliczono rozkład pola odmagnesowującego.
8
EN
The paper presents spatial distribution of base flow in the High Bieszczady Mts. (the Outer Carpathians). Discharges in 30 investigated catchments were measured in October 2009 during low flow period. Differences observed in unit base flow were varying from 0.9 dm>sup>3 s-1 km-2 in the Niedźwiedzi catchment to 6.8 dm3 s-1 km-2 in the Hulski catchment. Occurrence of colluviums is conducive to high values of base flow. On the other hand, low values of base flow are common to catchments drained by short and shallow streams. Correlations between unit base flow and stream density, altitude or geological unit were not proved.
9
Content available remote Wyznaczanie gęstości mocy czynnej metodą planimetrowania pętli histerezy
PL
Pokazano, że dla wyznaczenia gęstości mocy czynnej w próbce blachy elektrotechnicznej metodą planimetrowania pętli histerezy nie jest konieczny pomiar wartości chwilowych w równych odstępach fazowych. Nie jest również konieczne, aby odstępy fazowe dokładnie wypełniały okres. Te właściwości powodują, że metoda nadaje się do wyznaczania mocy próbek w zakresie dużych wartości chwilowych prądu magnesującego.
EN
It was shown that the measurement of instantaneous values in equal time intervals is not necessary to determine an active power density in electrical steel by means of hysteresis loop area planimetry. It is not also necessary accuracy filling of period by intervals between samples, These properties makes this method appropriate for determining of samples power in the range of high instantaneous values of magnetizing current.
10
Content available remote Statyczna metoda badania właściwości magnetycznych walcowych próbek magnesów
PL
Przedstawiono metodę badania właściwości magnetycznych próbek magnesów za pomocą zmierzonej indukcji pola zewnętrznego wytworzonego między biegunami elektromagnesu, zmierzonej indukcji w szczelinie nad powierzchnią próbki oraz obliczonych wartości natężenia pola odmagnesowującego. Pokazano, że tą metodą można badać również próbki magnesów o dużej koercji.
EN
A method of magnets characterization on the base of measurement of induction of external magnetic field generated between electromagnet poles and induction in the gap over sample surface and calculation of demagnetizing magnetic field strength was presented in this paper. It was shown that this method is also appropriate for magnets with high coercivity.
PL
Przedstawiono zastosowanie systemu do pomiaru właściwości magnetycznych materiałów ferromagnetycznych w polach wirujących do pomiaru anizotropii właściwości magnetycznych. Metoda nie wymaga obracania badanego obiektu lub aparatury pomiarowej podczas pomiaru, a jedynie sterowania systemem pomiarowym z poziomu programu operatorskiego.
EN
An application of computerized measuring system designed for measurement of magnetic properties of ferromagnetic materials under rotational fields to measurements of magnetic properties anisotropy is presented. An effective alternative solution for the measurement of magnetic properties in different directions, without the need to shift the sample or measuring apparatus but only by setting of measuring system by application program is proposed.
12
Content available remote Distant Electric Field Caused by Cloud to Ground Lightning
EN
In the paper we show the fine structure of distant electric field waveforms caused by first and subsequent lightning return strokes measured during summer thunderstorms near Warsaw in Poland. A conception based on two current waves generated in attachment point is used in order to explain sharp peaks registered within the front of electric field. From obtained computer simulations one can infer that current wave speed between the attachment point and the channel base, should be less than current wave speed usually assumed in lightning study.
PL
W artykule zaprezentowano przebiegi czasowe pola elektrycznego pierwszego i kolejnego piorunowego wyładowania głównego zarejestrowane w trakcie burzy w pobliżu Warszawy. W trakcie modelowania matematycznego czoła tych przebiegów wykorzystano koncepcję linii transmisyjnej, wzdłuż której rozchodzi się fala prądowa generowana w punkcie połączenia się lidera odgórnego z liderem oddolnym.
13
Content available remote Detektor przejścia małego prądu przez wartość zerową
PL
Detektor składa się z dwu komparatorów magnetycznych porównujących natężenia pola wytworzone przez prąd badany oraz przez prąd wysokiej częstotliwości. Modulowane są wtedy fazy impulsów wyjściowych z komparatorów magnetycznych. Fazy impulsów z obydwu komparatorów są jednakowe, gdy wartość chwilowa prądu badanego jest zerowa. Jeżli badany prąd przechodzi przez wartość zerową, to zmienia się kolejność impulsów z komparatorów. Przedstawiono układ i właściwości detektora, który wykrywa przejścia badanego prądu przez wartość zerową na podstawie kolejności impulsów z komparatorów magnetycznych.
EN
Abstrakt. A detector consists to two magnetic comparators which compare magnetic field intensity generated by tested current with magnetic field intensity generated by high frequency current. Then phases of output impulses of magnetic comparators are modulated. Phases of impulses from the both comparators are the same when instantaneous value of tested current equals zero. If examined current passes through zero value, then the sequence of impulse from comparators is changed. The circuit and properties of detector of passing of tested current by zero value based on sequence of impulse from magnetic comparators are presented.
14
PL
Przeprowadzono badania eksperymentalne i symulacje komputerowe rozpływu prądu udarowego w urządzeniu piorunochronnym niewielkiego obiektu budowlanego. Stwierdzono, że kształty przebiegów prądu wprowadzonego do urządzenia piorunochronnego oraz wpływającego do systemu jego uziemienia i do instalacji elektrycznej chronionego obiektu różniły się znacznie między sobą. Relacje wartości prądu wpływającego do instalacji elektrycznej do prądu wprowadzonego do urządzenia piorunochronnego, zależały od konfiguracji tego urządzenia.
EN
Experiments and computer simulations were conducted of surge current distribution in a lightning protective system (LPS) of a residential structure. It was found that waveshapes of currents: injected into the LPS, flowing into the grounding system and flowing into wiring system of the object, differed considerably from each other. Value relations of the current flowing into wiring system to the current injected into the lightning protective system depended on configuration of the LPS.
15
Content available remote Application of EMTP-RV Control Devices in Surge Arrester Modeling
EN
The paper presents some problems with nonlinear models of a surge arrester in EMTP-RV simulations. Obtained results show numerical instabilities of a selected 220 kV transmission line model for overvoltages with fast front caused by standard lightning surges defined in the IEC Standard 62305-1. For the EMTP circuit model an alternative approach with EMTP-RV control devices for ZnO arrester is presented. Simulated overvoltages illustrate control device diagrams utility.
PL
W pracy przedstawiono wybrane problemy modelowania nieliniowych ograniczników przepięć w symulacjach EMTP-RV. Otrzymane wyniki pokazują numeryczne niestabilności wybranego modelu linii elektroenergetycznej 220 kV dla przepięć ze stromym czołem, wywołanych standardowym udarem piorunowym zdefiniowanym w IEC Standard 62305-1. Dla modelu obwodowego EMTP zaproponowano alternatywne podejście z blokami funkcjonalnymi EMTP-RV dla ogranicznika ZnO. Użyteczność schematu blokowego potwierdzono symulacjami przepięć.
PL
W artykule przedstawiono i przedyskutowano zależność opóźnienia wykrycia przejścia prądu przez wartość zerową oraz zależność koercji dynamicznej magnetowodu z taśmy nanokrystalicznej od szybkości przejścia natężenia pola przez wartość zerową. Pokazano efekt obciążenia komparatora magnetycznego pojemnością i jego wpływ na zmniejszenie opóźnienia informacji o przejściu prądu przez wartość zerową. Przedstawiono również detektor przejścia prądu przez wartość zerową złożony z dwu komparatorów magnetycznych. Komparatory porównują natężenie pola wytworzone przez prąd o niskiej, energetycznej częstotliwości z natężeniem pola wysokiej częstotliwości. W zakresie małych wartości natężenia pola niskiej częstotliwości modulowana jest wtedy faza impulsów o wysokiej częstotliwości. Przejście prądu przez wartość zerową wykrywane jest na podstawie zmiany kolejności impulsów z poszczególnych komparatorów. Właściwości detektora działającego na zasadzie modulacji porównano z właściwościami detektora z komparatorem magnetycznym obciążonym pojemnością.
EN
In this article the dependence of the delay of current passing through zero value is presented and discussed, as well as the dependence of dynamic coercion of a magnetic core made of nanocrystalline ribbon on speed of passing of the current intensity through zero value. The effect of loading of the magnetic comparator with capacity and its influence on the decrease of delay of information about passing current through zero value is shown. We present also the detector of passing of current through zero value which is composed of two magnetic comparators. The comparators compare the current intensity generated by mains frequency current with the intensity of high frequency field. A phase of impulses with high frequency is then modulated in the region of low intensities of the low frequency field. The passing of current through zero value is detected on the basis of the change of sequence of impulses from different comparators. The properties of the detector operating on the basis of modulation are compared with those of the detector with one magnetic comparator loaded with.
PL
Metodą całkowania lub uśredniania półokresowych fragmentów sygnałów indukowanych w cewce H i w cewce B można dokładnie wyznaczyć pętlę histerezy nawet przy zasilaniu sieciowym. Stratność jest proporcjonalna do powierzchni pętli histerezy i może być prawidłowo wyznaczona również w zakresie dużych natężeń pola magnetycznego.
EN
Even at mains supply the hysteresis loop can be precisely determined by the method of integrating or averaging half-period fragments of signals induced in coil H and in coil B. Loss is proportional to the hysteresis loop area and it can be correctly determined also at high magnetic field strengths.
PL
Przedstawiono dyskusję czynników wpływających na wyniki oceny anizotropii właściwości magnetycznych blach elektrotechnicznych metodą anizometru indukcyjnego. Zaproponowano sposób eliminacji zasadniczej wady tej metody i przedstawiono propozycję nowej metody pomiaru anizotropii właściwości magnetycznych blach. Zaprezentowano również wyniki badań obu metod i ich ocenę merytoryczną. Uzasadniono potrzebę stosowania zaproponowanej nowej metody pomiaru anizotropii właściwości magnetycznych blach elektrotechnicznych.
EN
The factors affecting the evaluation of the anisotropy of the magnetic properties of electrical sheets by the induction anisometer method are discussed. A way of eliminating the main drawback of the this method is presented and a new method of measuring the anisotropy of the magnetic properties of electrical sheets is proposed. The two methods are compared and evaluated. The advantages of the new method of measuring the anisotropy of the magnetic properties of electrical sheets are described.
EN
The possibilities of nonlinear element modeling by control devices in EMTP-RV simulator for lightning overvoltage simulations are analyzed in the paper. The results are presented for back-flashover phenomenon on transmission line air gaps and for substation with nonlinear model of ZnO surge arrester. Tests of the Leader Development Model (LDM) for the flashover mechanism, which is supplied as a standard EMTP-RV device, are presented for the new standard waveshape of the lightning channel-base current. The block diagram of the substation model with last tower and ZnO surge arrester was made using standard control elements. Computer simulations for this model show its effectiveness and possibilities of its development.
20
Content available remote Wyznaczanie wielkości elektromagnetycznych w warunkach pracy obiektu
PL
W referacie przedstawiono możliwość wyznaczenia mocy czynnej i biernej oraz parametrów obwodów zastępczych obiektu na podstawie synchronicznie zmierzonych wartości średnich sygnałów liniowo przetworzonych napięć przyłożonych do obiektu i liniowo przetworzonych prądów pobieranych przez obiekt. Stosując do przetwarzania prądu czujniki indukcyjne i komparatory magnetyczne otrzymuje się sygnały dokładnie zależne od prądu w obwodach izolowanych galwanicznie od obwodów prądowych. Na podstawie tych sygnałów można dokładnie wyznaczyć moc czynną i bierną nawet przy dużych zniekształceniach prądów oraz przy dużym, jak i przy małym udziale mocy biernej.
EN
The paper presents possibility of determination of active and reactive power and object equivalent circuits parameters on the base mean values of synchronicaly measured and linearly converted signals of voltages and currents. By appling of inductive sensors and magnetic comparators for current converting the signals precisely dependent on current in galvanic insulated circuits are received. Basing on these signals it is possible to determine precisely the active and reactive power in the presence of high current distortions and both high and low share of reactive power.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.