Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 36

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
EN
Resistance gas sensors exhibit random phenomena (resistance noise) which can be utilized to improve gas sensitivity and selectivity. That new emerging technique has to be investigated to recognize optimal parameters for gas detection. It means that a measurement system has to have ability of numerous parameters adjustment (e.g., sampling frequency, heater voltage, polarization current, voltage noise amplification). That fact induced design of a new setup which limits a number of external power sources and reduces time of gas sensors characterization. The newly prepared system comprises two digitally controlled voltage and current sources, and a control unit to select polarization current of the investigated gas sensor. The system is controlled by the dedicated PC software used for data acquisition and communication. The system allows characterizing of prototype gas sensors having a very high resistance, up to tens of M?. Additionally, the measured sensors can be irradiated by the UV diode to induce photocatalytic effect influencing their gas sensing properties. All these operation have been automated. An every action is automatically logged and state of the system is visualized using windows PC environment. Output files are batch-processed by means of commercial software, such as MATLAB®. Additionally, some exemplary results of recent experimental data for selected gas sensors, such as their noise spectra at various sensors temperatures has been presented.
PL
W rezystancyjnych czujnikach gazu występują zjawiska losowe (np. szumy rezystancji), które mogą być wykorzystane do poprawy czułości i selektywności detekcji gazu. Aplikacja tej stosunkowo nowej techniki wymaga przeprowadzenia badań w celu ustalenia optymalnych parametrów detekcji gazów, co oznacza, że system pomiarowy powinien posiadać możliwość zmiany szeregu parametrów (np. częstotliwości próbkowania, napięcia grzałki, prądu polaryzacji, wzmocnienia napięcia szumów). Implikowało to konieczność zaprojektowania systemu z ograniczoną liczbą zewnętrznych źródeł zasilania i minimalizacji czasu charakteryzowania czujników gazu. Zbudowany system zawiera dwa cyfrowo sterowane źródła prądu i napięcia oraz układ sterujący wyborem prądu polaryzacji badanego czujnika gazu. System jest sterowany z komputera PC za pomocą opracowanego, dedykowanego oprogramowania i umożliwia charakteryzowanie prototypowych czujników gazu o rezystancji aż do dziesiątek M?. Czujnik może być ponadto poddany promieniowaniu przez diodę UV w celu wywołania efektu fotokatalizy, co wpływa na czułość detekcji gazu. Wszystkie wymienione czynności zostały zautomatyzowane w jak największym stopniu. Wszystkie wykonywane operacje są automatycznie rejestrowane, a aktualny stan systemu jest wizualizowany w postaci graficznej na monitorze PC. Pliki wyjściowe są przetwarzane wsadowo przy wykorzystaniu komercyjnego software’u takiego jak MATLAB®. Ponadto, przedstawiono przykładowe wyniki pomiarów uzyskane przy wykorzystaniu zaprojektowanego automatycznego stanowiska pomiarowego.
EN
Varistors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that comprized different ZnO grain types and can have various quality which changes continuously during exploitation (due to exposition to overheating and overvoltage pulses). Therefore, it is important to monitor varistors during their ageing (causing changes within their microstructures). A few methods of varistor property diagnosis were considered and compared with the methods currently applied in laboratory or industry applications. A new measurement (diagnostic) system that can monitor varistors during ageing and can be widely applied in power networks is presented. The proposed system fulfills requirements of the industrial customers which demand various methods for power line protection. The proposed system can be simply developed into a more advanced wireless diagnostic system of long power supply lines.
EN
The electro-ultrasonic spectroscopy as a new nondestructive method for varistor quality evaluation have been proposed. It is focused on non-homogeneities and defects detection in tested structures. Specially prepared samples having different structure of grains were preliminary measured by means of an Atomic Force Microscope. The system for electro-ultrasonic spectroscopy of high-voltage varistors has been described. The experimental results confirmed a possibility of heterogeneous structures detection directly after production or during exploitation.
PL
W artykule zaproponowano nową metodę nieniszczącego badania jakości warystorów za pomocą spektroskopii elektro-ultradźwiękowej. Metoda ta umożliwia detekcję defektów i niejednorodności struktury badanych warystorów. Specjalnie przygotowane próbki struktur warystorowych posiadających różną strukturę ziaren zostały wstępnie przebadane przyz użyciu mikroskopu sił atomowych. Przedstawiono system do spektroskopii elektro-ultradźwiękowej oraz rezultaty badań wybranych egzemplarzy warystorów wysokonapięciowych. Potwierdziły one możliwość detekcji różnej struktury ziaren bezpośrednio w trakcie produkcji warystorów oraz stopnia ich degradacji podczas eksploatacji.
PL
Przedstawiono bezprzewodową sieć sensorową, pobierającą i przekazującą informacje z czujników temperatury i oświetlenia sterowanych głosem. Funkcjonalność systemu może zostać wykorzystana do sterowania urządzeniami automatyki domowej. System składa się z trzech zasadniczych elementów: koordynatora sieci ZigBee, urządzenia końcowego (pomiarowego) wyposażonego w czujniki światła i temperatury oraz komputera PC. Użytkownik może zarządzać systemem za pomocą trzech interfejsów: komend głosowych rejestrowanych przez mikrofon, wyświetlacza TFT z panelem dotykowym oraz komputera PC z opracowanym oprogramowaniem. W koordynatorze zastosowano uproszczony algorytm rozpoznawania izolowanych słów przy pomocy współczynników LPC (Linear Predictive Coding). System został skonstruowany na popularnych mikrokontrolerach firmy STM z nowoczesnym mikroprocesorem ARM Cortex-M3.
EN
Wireless sensor network collecting and transferring information from temperature and lighting sensors controlled by means of operator’s voice has been presented. Functionality of the system can be applied for controlling of home automatic devices. The system consists of three main parts: ZigBee network coordinator, measuring terminals equipped in light and temperature sensors and computer PC. A user can manage the system by means of three interfaces: voice commands registered by the microphone, TFT display with touch panel and computer PC with elaborated software. In the coordinator the simplified algorithm of isolated words recognition by means of the LPC (Linear Predictive Coding) coefficients was applied. The system was realized using popular microcontrollers produced by STM with the modern microprocessor ARM Cortex-M3.
PL
W pracy przedstawiono metody oceny stanu technicznego warystorowych ograniczników przepięć średniego napięcia stosowane w badaniach laboratoryjnych oraz w eksploatacji - wykonywane bez wyłączania ograniczników z sieci. Analiza metod diagnostycznych została uzupełniona wynikami pomiarów prądu upływu ograniczników średniego napięcia (SN) bezpośrednio z produkcji nowych oraz eksploatowanych w energetyce zawodowej.
EN
The paper presents some practical methods of technical state of middle voltage ZnO surge arresters evaluation. Several methods of laboratory diagnostics and on – site checks were described. The analysis of commonly applied diagnostic me-thods was supplied by the results of leakage current measurements for new and degradated in exploitation middle voltage arresters.
EN
Standard industrial testing of high-voltage varistors for surge arresters demands application of high voltages and intensive currents. Nondestructive methods for varistor quality and endurance evaluation have been proposed and described. They rely on the application of resonant ultrasound spectroscopy, electroultrasonic spectroscopy, noise measurement and nonlinearity testing at voltages lower than continuous operating range. The achieved results show that these methods could be successively applied for varistor specimens at the production stage and in laboratory circumstances.
PL
Normatywne testy przemysłowe warystorów wysokonapięciowych stosowanych w ogranicznikach przepięć wymagają użycia wysokich napięć oraz prądów o odpowiednio dużych wartościach. Zaproponowano i opisano metody nieniszczące do oceny jakości i trwałości warystorów. Polegają one na zastosowaniu rezonansowej spektroskopii ultradźwiękowej, spektroskopii elektro-ultradźwiękowej, pomiarów szumów i testowaniu nieliniowości w zakresie napięć mniejszych od ciągłego napięcia pracy. Uzyskane wyniki wskazują, że metody nieniszczące mogą być z powodzeniem stosowane w odniesieniu do struktur warystorowych, zarówno w warunkach produkcyjnych jak i laboratoryjnych.
7
Content available Ultrasonic spectroscopy of silicon single crystal
EN
Specimens of Si single crystals with different crystal orientation [100] and [110] were studied by Electro-Ultrasonic Spectroscopy (EUS) and Resonant Ultrasonic Spectroscopy (RUS). A silicon single crystal is an anisotropic crystal, so its properties are different in different directions in the material relative to the crystal orientation. EUS is based on interaction of two signals: an electric AC signal and an ultrasonic signal, which are working on different frequencies. The ultrasonic wave affects the charge carriers' transport in the structures and the intermodulation electrical signal which is created due to the interaction between the ultrasonic wave and charge carriers, is proportional to the density of structural defects. RUS enables to measure natural frequencies of free elastic vibrations of a simply shaped specimen by scanning a selected frequency range including the appropriate resonances of the measured specimens.
PL
Opisano metodę oceny jakości foliowych kondensatorów przeciwzakłóceniowych za pomocą badania ich drgań w zakresie ultradźwięków pod wpływem impulsowego sygnału pobudzającego. Indukowane drgania są źródłem informacji o jakości zwinięcia zastosowanej w kondensatorze folii oraz wykonanych kontaktach. Przedstawiono układ impulsowego pobudzenia kondensatora oraz system do pomiaru sygnału ultradźwiękowego. Uzyskane wyniki pomiarów dla grupy kondensatorów klasy Y2 o pojemności 27 nF skonfrontowano z wynikami pomiarów współczynnika trzeciej harmonicznej oraz pochodnej tego współczynnika w funkcji napięcia polaryzacji.
EN
The method of a foil capacitor for interference suppression quality evaluation by means of an ultrasonic emission signal analysis stimulated by an impulse signal has been described. Induced oscillations are a source of information about the quality of foil winding and prepared contacts. The circuit for the pulsed stimulation of a capacitor and the system for the ultrasonic signal measurement are presented. Achieved results for the batch of Y2 class capacitors with capacity of 27 nF were compared with the measurement results of third harmonic index and with derivative of this index as a function of biasing voltage.
PL
Bezprzewodowe sieci sensorowe najczęściej wykorzystywane są w systemach pomiarowo-kontrolnych. Przy realizacji systemu wykorzystano mikrokontroler z rdzeniem Cortex-M3 jako kontroler sieci oraz przekaźniki ZigBee pracujące przy częstotliwości 2,4 GHz. System wymagał stworzenia modułów komunikacyjnych łączących kontroler i przekaźnik radiowy za pomocą interfejsu SPI oraz zaimplementowania stosu odpowiadającego potrzebom aplikacji. Opracowano oprogramowanie sterujące bezprzewodowo pracą urządzeń automatyki za pomocą mikrokontrolera STM32 w oparciu o standard IEEE 802.15.4 oraz kompleksowe, wielofunkcyjne sterowanie systemem z komputera PC.
EN
Wireless sensor networks are the most often used in measurement-control systems. A microcontroller with Cortex-CPU as a network controller and ZigBee transmitter working at 2.4 GHz have been applied in the presented system. Communication modules connecting the controller and the radio transmitter through SPI interface and a stack implementation related to requirements of the application had to been created. A software wirelessly controlling of automatics devices by means of the STM32 microcontroller in the IEEE 802.15.4 standard and the multifunctional controlling of the whole system from a PC have been prepared.
10
Content available remote Pomiary wyładowań niezupełnych w kondensatorach foliowych
PL
Występowanie zjawisk wyładowań niezupełnych w dielektrykach kondensatorów foliowych wpływa na skrócenie ich czasu życia. Stąd, pomiary parametrów wyładowań niezupełnych i ich analiza mogą się przyczynić do poprawy jakości produkowanych kondensatorów. Stosowane metody pomiarowe wyładowań niezupełnych bazują na efektach, jakie te wyładowania wywołują w kondensatorach. Zjawiska wyładowań powodują przepływy prądów, co umożliwia pomiary metodami elektrycznymi. Wyładowania niezupełne są także źródłem emisji akustycznej – fal ultradźwiękowych, typowo do częstotliwości kilkuset kHz. Analiza wyników pomiarów elektrycznych i akustycznych wyładowań niezupełnych w kondensatorach i ich związków z innymi parametrami kondensatorów może potencjalnie pozwolić na oszacowanie czasu życia oraz jakości danego typu kondensatorów. Z podanych względów warto przybliżyć problemy pomiarów oraz charakteryzowania wyładowań niezupełnych, co jest głównym zagadnieniem poruszanym w pracy. Poza układami do pomiarów wyładowań niezupełnych, przedstawiono przykłady degradacji struktury kondensatorów w wyniku występowania wyładowań.
EN
Partial discharges within the foil-based capacitors limit their lifetime. Thus, measurements of partial discharges parameters and their analysis can improve quality of the fabricated capacitors. The applied measurement methods utilize effects caused by partial discharges in capacitors. The discharges cause current flows that can be observed by electrical methods. Partial discharges generate acoustic emission signals (acoustic waves up to a few hundreds of kHz) as well. Analysis of the measurement results of partial discharges using electrical and acoustical methods and their correlation with other electrical parameters can probably allow to estimate their lifetime and quality. Because of these reasons it is valuable to raise an issue of partial discharges measurement and analysis problems. Together with the measurement systems various types of the induced degradations of capacitors were enclosed.
PL
W projekcie systemu integrującego architekturę J2EE z interfejsem pomiarowym 1-wire wykorzystano: platformę TINI jako system bazowy, klucze iButton jako metodę identyfikacji, sieć internetową jako sposób integracji z innymi systemami, J2EE jako model architektury logicznej oraz technologię JSP, Sun Application Server i MySQL. System umoSliwia dodanie i usunięcie klucza z bazy danych, zapisanie historii interakcji, dostarczenie mechanizmu odblokowującego dostęp do określonej lokalizacji. Oprogramowano system implementując funkcjonalność pomiaru temperatury, zarządzania dostępem do pomieszczeń, a takSe akwizycji czasu pracy. Większość prac programistycznych zostało przeprowadzonych w zintegrowanym środowisku Integrated Development Environment. Platforma umoSliwia pisanie kodu w wielu językach programowania. Zaletą platformy jest zintegrowanie jej z serwerem aplikacyjnym Glassfish oraz bazami danych MySQL. Programowanie platformy TINI odbywało się w trybie kilkukrokowym, a program uruchamiany był w konsoli tekstowej udostępnianej przez protokół TELNET.
EN
In the design of the system integrating the J2EE architecture with 1-wire measurement interface the following features have been applied: TINI platform as a base system, iButton switches as a method of identification, internet network as a way of integration with o ther systems, J2EE as a model of logical architecture, and JSP technology, Sun Application Server and SQL. System enables adding and removal of a switch from data base, saving the interaction history and gives the mechanism of clearing an access for particular localization. The system was programmed by implementation of temperature measurement functionality, management of an access to working rooms, and also working time acquisition. The most programming works have been developed in the Integrated Development Environment. The platform enables a code writing in many programming languages. The advantage of the platform is its integration with Glassfish application server and MySQL data bases. A TINI platform programming has been realized in the several step modes, and program was executed in the text console extended by the TELNET protocol.
PL
Rezonansowa spektroskopia ultradźwiękowa jest efektywną metoda testowania nieniszczącego ukierunkowaną na wykrywanie defektów w badanych obiektach. Procedura testująca bazuje na wzorcu rezonansów i danego obiektu, co umożliwia odrzucenie testowanych próbek nie odpowiadających wzorcowi. W zbudowanym systemie do testowania warystorów wysokonapięciowych zastosowano metodę "przemiatania" częstotliwości do pomiaru widma rezonansów, których częstotliwości zależą od niejednorodności struktury warystora. Jako kryterium testowania zaproponowano parametr jakości struktury Q, na podstawie którego proponuje się eliminację wadliwych elementów we wczesnej fazie procesu produkcyjnego.
EN
Resonant ultrasound spectroscopy is an effective nondestructiye testing method focused on defects in tested objects. The testing procedure based on the resonant pattern allows to reject tested samples with defects do not fitting the pattern. A swept frequency method has been used to measure the spectrum of resonances in high-voltage varistors. The resonant frequencies depend on the varistor heterogeneity. The quality of the structure parameter Q has been proposed as a criterion for the "go- no go" testing for elimination of the defected elements in the preliminary stage of the varistor manufacturing process.
PL
Przedstawiono nową nieniszczącą metodę wykrywania defektów dwójników. W metodzie wykorzystuje się wzajemne oddziaływanie fononów ultradźwiękowych i elektronów wskutek istnienia defektu powodującego nieliniowości. Testowana próbka jest pobudzana przez sygnały harmoniczne: elektryczny i ultradźwiękowy o różnych częstotliwościach. Wskutek nieliniowości powodowanej przez defekt struktury próbki powstaje nowy sygnał harmoniczny o częstotliwości różnicowej sygnałów stymulujących. Opisano skrótowo system spektroskopii elektroultradźwiękowej. Zaproponowana metoda została zweryfikowana przy pomiarach warysto-rów wysokonapięciowych. Podano zależność amplitudy sygnału intermodulacyjnego w funkcji poziomu sygnałów pobudzających.
EN
The paper describes a new non-destructive testing method for conducting solids with defects or cracks. The method is based on nonlinear effects created by a harmonic motion of atoms subjected to ultrasonic vibrations. Physical principle follows from ultrasonic phonons interaction with electrons on defect caused nonlinearity. Tested sample is excited by harmonic electrical and ultrasonic signals with different frequencies. On the defect caused nonlinearity a new harmonic signal is created with frequency given by subtraction of excited frequencies. The system for electro-ultrasonic spectroscopy measurements has been briefly described. The method was verified for high-voltage varistors measurements. The dependence of an amplitude of intermodulation component versus levels of ultrasonic and electrical excitations has been determined experimentally.
14
Content available remote Quality assessment of high voltage varistors by third harmonic index
EN
High voltage varistors that consist mainly of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistor quality assessments by a third harmonic index measurement at relatively low voltage range. In this experimental study it has been proved that the proposed procedure can be applied successfully for preliminary selection of the tested structures.
PL
Przedstawiono nową metodę badań nieniszczących elementów przewodzących do wykrywania defektów. W metodzie wykorzystano efekty nieliniowe powstające wskutek nieharmonicznego ruchu atomów podlegających wibracjom ultradźwiękowym (wzajemnego oddziaływania fononów ultradźwiękowych i elektronów wskutek istnienia defektu powodującego nieliniowości). Testowana próbka jest pobudzana przez sygnały harmoniczne: elektryczny i ultradźwiękowy o różnych częstotliwościach. Wskutek nieliniowości powodowanej przez defekt struktury próbki powstaje nowy sygnał harmoniczny o częstotliwości różnicowej sygnałów stymulujących. Opisano system do pomiaru spektroskopii elektro-ultradźwiękowej. Zaproponowana metoda została zweryfikowana przy pomiarach warystorów wysokonapięciowych. Stwierdzono, że amplituda sygnału intermodulacyjnego jest liniową funkcją pobudzającego sygnału ultradźwiękowego.
EN
The paper describes new non-destructive testing method of conducting solids with defects or cracks. This method is based on nonlinear effects created by anharmonic motion of atoms subjected to ultrasonic vibrations. Physical principle follows from ultrasonic phonons interaction with electrons on defect caused nonlinearity. Tested sample is excited by harmonic electrical and ultrasonic signals with different frequencies. On the defect caused nonlinearity new harmonic signal is created with frequency given by subtraction of excited frequencies. The system for electro-ultra-sonic spectroscopy measurements bas been described. The method was verified by high-voltage varistors measurements It was found that amplitude of intermodulation component is linear function of ultrasonic excitation.
PL
Przedstawiono system pomiarowy wybranych parametrów urządzeń naziemnej infrastruktury systemów komórkowych pracujący w standardzie E1. System został zbudowany na bazie komputera PC wyposażonego w kartę standardu E1 i zawiera opracowane i zaimplementowane oprogramowanie. Badania eksperymentalne obejmowały weryfikację poprawności działania systemu pomiarowego. Przeprowadzono je testując wykorzystywane w systemie GSM radiolinie firmy NOKIA, umożliwiające bezprzewodowe przesyłanie danych cyfrowych. Zmierzono bitową stopę błędów transmisji w jednej szczelinie czasowej przy zastosowaniu kodowania Hamminga.
EN
The measurement of selected parameters of mobile cellular ground infrastructure working in the standard E1 have been presented. The system has been constructed on the basis on PC equipped with computer card of standard E1 controlled by the elaborated and implemented software. Experimental studies involved the verification of system functionality. They have been carried out using the NOKIA microwave radios in the GSM system enabling wireless data transmission. The bit error rate in the one timeslot using Hamming coding has been measured.
PL
W pracy zaprezentowano wyniki komputerowej weryfikacji cyfrowego układu CMOS utworzonego z klastrów Cn-1, Cn-2, …, Ci, … C0, z których każdy jest zasilany odpowiednio malejącymi wartościami napięć Vddn-1 > Vddn-2 > … > Vddi > … > Vdd0 . Zbiór klastrów {Ci} został utworzony przy pomocy algorytmu ECA (Evolutionary Clustering Algorithm) dla potrzeb redukcji mocy pobieranej ze źródła zasilającego. Otrzymane rozwiązanie charakteryzujące się zmniejszeniem zapotrzebowania na moc zasilającą nie powoduje pogorszenia przepustowości zaprojektowanego systemu cyfrowego CMOS.
EN
The paper presents results of a computer simulation of a CMOS digital circuit composed of Cn-1, Cn-2, …, Ci, … C0 clusters. The clusters are supplied with voltages Vddn-1 > Vddn-2 > … > Vddi > … > Vdd0, respectively. Set of clusters {Ci} was created with aid of ECA (Evolutionary Clustering Algorithm) for reduction of power dissipated. The obtained result enables for power reduction without deteriorating the throughput of the designed CMOS circuit, measured as system latency.
EN
Noise measurements are promising tool to provide information and nondestructive characterization of electronic components and other objects (noise spectroscopy). Noise data can improve selectivity and sensibility of gas detection (electronic nose) or monitor corrosion phenomena. As the main diagnostic tool it is proposed to use low frequency current and voltage fluctuations and their statistical properties. Some selected results of noise measurements have been discussed in the paper due to their practical importance.
PL
Pomiary szumów są źródłem informacji oraz rodzajem badań nieniszczących dotyczących jakości elementów elektronicznych oraz innych materiałów. Mogą one poprawić selektywność i czułość wykrywania gazów oraz pozwalają na monitorowanie zjawiska korozji. W tym celu wyznacza się właściwości statystyczne fluktuacji prądu lub napięcia w zakresie małych częstotliwości. W artykule przedstawiono i przedyskutowano wybrane, ze względu na ich znaczenie w praktyce, wyniki pomiarów sygnałów losowych.
19
Content available Analysis of nonlinear effects as a diagnostic tool
EN
Methods of nonlinear effects analysis al the output signal of tested objects give the possibility of defects and damage examination in materials and electronic devices what is useful in reliability prediction. For passive elements a very effective tool exemplifies Third Harmonic Index (THI). The THI measurements for interference suppressor capacitors and its properties have been described in detail. The application of bispectrum in analysis of resistance fluctuations in gas sensors was briefly presented. Advantages of nonlinear spectroscopy in non-destructive testing of objects have also been pointed out.
PL
Metody analizy efektów nieliniowych nieliniowej analizy sygnałów na wyjściu testowanych obiektów umożliwiają badanie występowania defektów i uszkodzeń w materiałach i elementach elektronicznych, co jest niezbędne w predykcji niezawodności. W odniesieniu do elementów biernych bardzo skutecznym narzędziem okazuje się być wskaźnik trzeciej harmonicznej (THI -- Third Harmonic Index). W artykule bardziej szczegółowo opisano pomiary parametru THI i jego właściwości dla kondensatorów przeciwzakłóceniowych. Skrótowo przedstawiono zastosowanie bispektrum w analizie fluktuacji rezystancji czujników gazu. Wyszczególniono również zalety spektroskopii nieliniowej w badaniach nieniszczących obiektów.
EN
Non-linearity and noise properties of a capacitor have been analysed to established criteria for selection of interference suppressor capacitors for different endurance (sustainability) and reliability groups. It can improve the process of quality estimation of high reliability capacitors. Selected experimental results of measurements for capacitors produced by MIFLEX (Poland) have been presented. The implementation of techniques for non-linearity and noise measurements in the system for production testing of high reliability interference suppressor capacitors is described.
PL
Przeanalizowano właściwości nieliniowe i szumowe kondensatora w celu ustalenia kryteriów selekcji kondensatorów przeciwzakłóceniowych na grupy o zróżnicowanej trwałości (jakości). Może to udoskonalić proces oceny jakości kondensatorów o podwyższonej trwałości. Przedstawiono wybrane wyniki eksperymentalne pomiarów kondensatorów wytwarzanych w ZPR MIFLEX S.A. w Kutnie. Opisano zastosowanie technik pomiaru nieliniowości i fluktuacji w systemie do produkcyjnego testowania kondensatorów przeciwzakłóceniowych o podwyższonej trwałości.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.