EN
During the course of the study it involved tool steel C105U was used. The steel was austempered at temperatures of 130°C, 160°C and 180°C respectively. Methods of acoustic emission (AE) were used to investigate the resulting effects associated with transformations and a large number of AE events were registered. Neural networks were applied to analyse these phenomena. In the tested signal, three groups of events were identified of: high, medium and low energy. The average spectral characteristics enabled the power of the signal spectrum to be determined. After completing the process, the results were compiled in the form of diagrams of the relationship of the AE incidence frequency as a function of time. Based on the results, it was found that in the austempering of tool steel, in the first stage of transformation midrib morphology is formed. Midrib is a twinned thin plate martensite. In the 2nd stage of transformation, the intensity of the generation of medium energy events indicates the occurrence of bainite initialised by martensite. The obtained graphic of AE characteristics of tool steel austempering allow conclusions to be drawn about the kinetics and the mechanism of this transformation.
EN
The research was carried out on steel 100CrMnSi6-4 under isothermal austempering resulting in forming the duplex structure: martensitic and bainitic. The kinetics of transformation was controlled by the acoustic emission method. Complex phase transformations caused by segregation and carbide banding occur at the low-temperature heat treatment of bearing steel. At the temperature close to Ms, a certain temperature range occurs where an effect of the first product of prior athermal martensite on the bainitic transformation can be observed. In the registered signal about 15 million various events were registered. There were considered three types of acoustic emission events (of high, medium and low energy), with relatively wide sections and with different spectral characteristics. It was found that the method of acoustic emission complemented by the application of neural networks is a sensitive tool to identify the kinetics of bainitic transformation and to show the interaction between martensitic and bainitic transformations.
PL
Badania realizowano na stali 100CrMnSi6-4 poddanej hartowaniu izotermicznemu, prowadzacemu do utworzenia struktury duplex: martenzytyczno-bainitycznej. Kinetykę przemian kontrolowano metodą emisji akustycznej. Przy niskotemperaturowej obróbce cieplnej stali łożyskowej występują złożone przemiany fazowe spowodowane segregacją i pasmowością węglików. W temperaturze zbliżonej do Ms, występuje pewien zakres temperatury, gdzie zaznacza się oddziaływanie wcześniejszego produktu przemiany martenzytycznej na przemianę bainityczną. W zarejestrowanym sygnale zarejestrowano około 15 milionów różnych zdarzeń. Uwzgledniono trzy rodzaje zdarzeń emisji akustycznej (o wysokiej, średniej i niskiej energii) o względnie szerokich przedziałach, o różnej charakterystyce widmowej. Stwierdzono, że metoda emisji akustycznej uzupełniona o zastosowanie sieci neuronowych jest czułym narzędziem do identyfikacji kinetyki przemiany bainitycznej oraz oddziaływania przemiany martenzytycznej na przemianę bainityczną.
PL
Zbadano możliwości zastosowania systemów termograficznych do badania wymuszeń termicznych związanych z zastosowaniem niskich temperatur. Termograficzna technika pomiarowa w podczerwieni pozwala na szybką i dokładną kontrolę procesu chłodzenia. Dzięki zobrazowaniu rozkładu temperatury jesteśmy w stanie ocenić jakość i poprawność zaaplikowanego impulsu termicznego oraz sprawdzić, czy reakcja na zastosowane wymuszenie termiczne jest prawidłowa. Stwierdzono, że stosowane obecnie w krioterapii wymuszenia termiczne nie zapewniają w pełni poprawnego diagnozowania termowizyjnego ze względu na brak powtarzalności impulsu termicznego. Intensywność zabiegu, czas jego trwania i precyzja wykonania są ściśle związane z umiejętnościami personelu. Opracowano więc, metodykę i stanowisko zapewniające powtarzalność przeprowadzenia wymuszenia termicznego i dokonano analizy uzyskanych wyników.
EN
The aim of the following dissertation is to presentthe possibility of thermographic systems application for the examination of thermal stimulations. The infrared measurement techniques allow for a faster and more precise monitoring of the cooling process. The imaging of temperature distribution on the surface of the body makes it possible to evaluate the quality and correctness of the thermal impulse applied, as well as to determine if the response to the thermal stimulation used is adequate. It has been found that currently used thermal stimulations do not guarantee a completely accurate thermographic diagnosis due to the lack of repeatable thermal impulse. The intensity and time of procedure, as well as the accuracy during procedure performing are closely connected with the skills of the staff involved. The device for the examination of response to thermal stimulation has been developed as the effect of scientific research. The research methodology and the process of object preparation for thermographic research have been developed and accepted.
EN
Non-invasive method of the measurement and identification of shape and geometrical characteristics of measured detail based on the computer tomograph is widely applied in medicine with high efficiency. The paper is aimed at presenting the metrological analysis of the accuracy of shape reproduction. The examined shape was described due to the tomography and compared to the results of coordinate measurement. The comparative accuracy analysis of the tomography was performed for the typical details, as well as for the masters made with high accuracy. Using the results of the analysis, the respective models of measured details were created and used as a nominal in the further investigations. The results of the measurement with tomography were compared with the results achieved from the measurement by means of typical coordinate measuring machines and by means of 3D measurement optical scanner. Analysis of the gained values of the form deviations and important geometrical characteristics enabled to perform complex analysis of the shape reproduction of the examined detail with the method of computer tomography. The main purpose of the performed researches was the determination of the reproduction accuracy of surface measured with non-invasive computer tomography method. The investigations and analysis have been performed with the following equipment: computer tomograph, 3D printer and coordinate optical scanner supported with specialized software for advanced CAD data analysis.
EN
The possibility of detection the hidden defects or damage applying the methods of dynamic infrared thermography and the 2D discrete wavelet transform of data measured in thermal processes has been described. Besides of theoretical information about application of these transforms results of MES digital simulations as well as qualitative experimental has been presents.
PL
Działanie wielu zabiegów fizykalnych stosowanych w medycynie wiąże się ze zmianami temperatury tkanek. Przeprowadzono badania dotyczące możliwości wykorzystania techniki termograficznej do oceny skuteczności zabiegu krioterapii miejscowej (kriostymulacji miejscowej) u pacjentów z reumatoidalnym zapaleniem stawów. Badanie przeprowadzono w celu określenia stopnia intensywności wymuszenia termicznego podczas zabiegów krioterapii miejscowej i czasu trwania odpowiedzi organizmu na zastosowane wymuszenie. Badanie oparto na porównaniu rozkładu temperatury na powierzchni dłoni przed, zaraz po zabiegu miejscowego nadmuchu oparami ciekłego azotu lub zimnego powietrza na dłoń oraz w pewnych okresach czasu po zabiegu. Wszystkie osoby poddane badaniu były chore na reumatoidalne zapalenie stawów, u niektórych badanych występowały również inne choroby towarzyszące. Podobne procedury wykorzystano do badania reakcji współzmienniczych związanych ze stosowaniem kremów antycellulitowych. W obydwu przypadkach można było zaobserwować podobne reakcje organizmu na zastosowane wymuszenie. Badania pozwoliły na zoptymalizowanie procedur stymulacji termicznej stosowanych w reumatologii i kosmetologii.
EN
Many medical procedures cause the thermal changes of flesh and tissues. In the paper, the investigation on the possibilities of thermographic technique application for evaluation of the criotherapy procedure success (local criostimulation) have been described. The people with rheumathoid arthritis underwent the criogenic treatment in order to evaluate the degree of local thermal stimulation and the time of the organism response. The investigations have been based on the temperature distribution on the palm surface before the treatment with cooled air or liquid nitrogen, immediately after, and in certain time periods. The similar examination had been held in the investigations of the related variables after cellulitis treatment with creams. The organism reactions are very similar in both cases. The investigations have led to the optimization of procedures of thermal stimulation in rheumatology and cosmetology.