Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper reports on analyses and testing of sensitive power electronics components encapsulation concept, enabling operation in harsh, especially high pressure environments. The paper describes development of the concept of epoxy modules that can be used for protecting of the power electronics components against harsh environmental conditions. It covers modeling of the protective capsules using a simple analytical approach and Finite Element Method (FEM) models and validation of the developed models with the high pressure tests on samples fabricated. The analyses covered two types of the epoxy modules: of sphere- and elongated- shape, both with electrical penetrators that enable electrical connection of the encapsulated components with external power sources as well as other power modules and components. The tests were conducted in a pressure chamber, with a maximum applied pressure of 310 bars, for which online strain measurements have been conducted. The experimental results were compared with the simulation results obtained with analytical and FEM models, providing validation of the models employed. The experimental part of this work was conducted in collaboration with Polish Naval Academy in Gdynia.
PL
Przedstawiono szczegóły działania algorytmu wieloczęstotliwościowego zabezpieczenia admitancyjnego wykorzystującego kumulacyjną sumę fazorową (CPS).
EN
Article decribes details of the multifrequency admittance protection algorithm utilizing cumulative phasor sum (CPS).
EN
In electric power products development, thermal aspects are becoming very important because they guarantee the correct operation of product. The specified temperature limits cannot be exceeded. Thus, knowledge of temperature behavior is very important factor in order to predict reliability and performance in its working environment. In this paper some bases of Thermal Network Method (TNM) modeling in application to transient rating calculations of typical GIS compartment arrangements are presented. Thermal network composed of heat sources, thermal resistances and capacitances can be easily represented and calculated by means of ATP-EMTP programs (also OrCAD Capture environment).
PL
W dobie rozwoju produktów energii elektrycznej, aspekty cieplne stają się bardzo ważnym czynnikiem, ponieważ w celu zagwarantowania prawidłowego działania urządzeń i aparatów elektrycznych, temperatury nie powinny przekraczać wartości dopuszczalnych. Analiza warunków termicznych jest bardzo ważnym czynnikiem w celu przewidzenia skuteczności i niezawodności w danym środowisku pracy. W poniższym artykule zostały zaprezentowane podstawy modelowania z zastosowaniem metody sieci termicznych – metoda pozwala na wykonywanie obliczeń wartości znamionowych w typowych modułach stacji typu GIS. Sieć termiczna składa się ze źródła ciepła, rezystancji i pojemności termicznej oraz została zaprezentowana i zasymulowana w środowisku ATP-EMTP (a także w programie OrCAD Capture).
4
Content available remote Reduction of THD by switching frequency optimization in three-level NPC inverter
EN
This paper aims to describe the effect of switching frequency selection for three-level NPC inverter and its impact on the quality of output waveforms for different cable lengths connecting the inverter with motor. Authors propose an optimal switching frequency selection as an option to overall limitation of THD. Traditional and the most popular techniques to limit the THD have been reviewed in order to compare with the proposed method. Simulation verification shows that harmonic spectrum generated by the inverter with the switching frequency selected at the minimum equivalent impedance of the network cable resulting in decrease of total level of harmonics contents.
PL
W artykule została przedstawiona analiza wyboru częstotliwości przełączania trójpoziomowego falownika napięcia, oraz jej wpływu na jakość przebiegów wyjściowych dla różnych długości kabli. Autorzy proponują wybór częstotliwości przełączania, jako jedną z opcji ograniczenia współczynnika THD. W artykule przedstawiono tradycyjne i najbardziej popularne techniki ograniczenia współczynnika THD w celu ich porównania z proponowaną metodą. Wyniki symulacyjne wykazały, że ilość harmonicznych generowanych przez falownik jest mniejsza, jeśli falownik pracuje przy częstotliwości, dla której impedancja zastępcza kabla jest najmniejsza.
PL
Przedstawiono problemy pomiaru impedancji pętli zwarciowej w linii elektroenergetycznej z odgałęzieniem dla lokalizatora zwarć skojarzonego z prądowymi zabezpieczeniami różnicowymi. Pomiar przeprowadza się dla trzech hipotetycznych zwarć, położonych w poszczególnych sekcjach linii, a następnie dokonuje się selekcji rezultatu, który odpowiada rzeczywistemu zwarciu. Przy pomiarze impedancji kompensowany jest wpływ rezystancji przejścia w miejscu zwarcia. Przedstawiono przykład pomiaru z użyciem sygnałów z symulacji komputerowej.
EN
Issues related to fault-loop impedance measurement in a three-terminal power line for a fault locator associated with current differential relays are presented. The measurement is carried out for three hypothetical faults located at particular line sections and then the result consistent with the real fault is selected. Influence of fault path resistance on the measurement is compensated for. A sample measurement with use of signals from computer simulation is presented.
PL
W artykule przedstawiono wybrane aspekty analizy koordynacji izolacji wykorzystywane w praktyce projektowania stacji wysokich i najwyższych napięć. Omówiono główne założenia typowych analiz przepięciowych oraz przedstawiono metody obliczeniowe wspomagające proces poprawnego doboru środków ochrony odgromowej. Przedstawiono metody modelowania narażeń przepięciowych oraz modele poszczególnych elementów systemu, istotnych z puntu widzenia koordynacji izolacji. Szczególny nacisk położono na uwzględnienie zjawisk nieliniowych oraz charakterystyk częstotliwościowych, pozwalających na uzyskanie wymaganej dokładności obliczeń. Przedstawiono wyniki przykładowej analizy wpływu długości linii kablowej na wartości przepięć występujących w miejscu zainstalowania transformatora. Analizę przepięciową przeprowadzono dla schematu jednokreskowego typowej stacji rozdzielczej wysokich napięć w izolacji gazowej typu SF6, dla której przyjęto typowe parametry konstrukcyjne linii napowietrznych i kablowych, parametry konstrukcji wsporczych linii napowietrznych, oraz modele aparatów i urządzeń stacji wraz z doprowadzeniami, w szczególności modele transformatorów oraz ograniczników przepięć. Dla ograniczników przepięć dokonano oceny skuteczności i niezawodności ograniczników, związanej ze zdolnością ograniczników do pochłaniania i skutecznego odprowadzania energii wydzielanej podczas zadziałania, oraz pozwalającej na weryfikację poprawności doboru ograniczników dla pracy w danych warunkach przepięciowych. Przedstawiona w pracy analiza wskazuje, że połączenia kablowe mogą w znaczny sposób zmieniać narażenia powstałe w wyniku przepięć atmosferycznych w linie dochodzące do stacji, a tym samym wpływać na narażenia napięciowe, jakim w trakcie eksploatacji poddawane są układy izolacyjne aparatów i urządzeń.
EN
In the paper practical aspects of insulation co-ordination analyses are presented for high and ultra high voltage Gas Insulated Switchgear substations. Modeling methods are elaborated for proper selection of overvoltage protection measures, such as surge arresters, overhead lines towers grounding system, and line insulators chain lengths. The methods of lightning surges and substation equipment modeling were presented with special interest in modeling of nonlinear phenomena and high frequency characteristics, allowing for the required accuracy of the simulation results. The results for exemplary insulation co-ordination analysis are presented, showing the cable line impact on the substation overvoltages. The analysis was performed for a Single Line Diagram of an exemplary typical High Voltage GIS substation, for which a typical configuration and parameters of the elements have been assumed: overhead lines, substation apparatus, transformers and surge arresters. For the surge arresters, the analysis of the arresters reliable and efficient energy dissipation was analyzed, which allowed for evaluation and verification of proper selection and operation of the equipment in given voltage stress conditions and the assumed substation layout. The analyses presented in the paper shows that the cable line connections within or between substations have significant impact on overvoltages, which can threaten insulation system of transformers and can also influence selection of number and location placement of the surge arresters.
EN
This paper presents detailed analysis of phenomena which occur in cable connection between the drive and the motor. The impact of cable length on the proper inverter operation as well as protection against additional stress of motor caused by reflection in cable is analyzed, on a model developed for this purpose. Several configurations of output LC filters were implemented to investigate the optimal solution to reduce transient effect caused by dv/dt and high order harmonics.
PL
W artykule przedstawiono analizę zjawisk występujących w układzie zasilania silnika indukcyjnego z trójpoziomowego falownika napięcia poprzez linię kablową. Zbadano wpływ długości linii kablowej na przebiegi wyjściowe falownika dla różnych konfiguracji filtra. Celem badań było ustalenia topologii filtra zapewniającej uniwersalność rozwiązania napędu przekształtnikowego, a zarazem eliminującej niekorzystne zjawiska występujące w tego typu układach.
8
Content available remote Fault location on double-circuit transmission line not requiring line parameters
EN
A new impedance-based algorithm for fault location on overhead double-circuit lines is presented. To assure high precision for fault location the considered calculations are based on distributed-parameter line model and the line parameters are estimated. Selected results of the evaluation of fault location accuracy with use of the signals from the ATP-EMTP simulations are presented and discussed.
PL
Przedstawiono nowy impedancyjny algorytm lokalizacji zwarć w dwutorowej napowietrznej linii elektroenergetycznej. W celu zapewnienia dużej dokładności lokalizacji zastosowano model linii o parametrach rozłożonych i dokonano estymacji parametrów linii. Zamieszczono i omówiono wybrane rezultaty badań dokładności lokalizacji przeprowadzanej z użyciem sygnałów z symulacji zwarć za pomocą programu ATPEMTP.
EN
In the present paper simulations of the lightning overvoltages propagation phenomenon in a typical 420 kV SF6 GIS substations are presented. A new overvoltage mitigating passive device in a form of a high-voltage L-C filter is proposed. A process of its development and research is explained along with a simulation results. As demonstrated, the proposed device can be used in HV networks as an alternative or additional improvement for lightning overvoltages mitigation purposes. All simulations have been conducted using MATLAB and ATP/EMTP software.
PL
W artykule przedstawiono symulacje wyładowań atmosferycznych i propagacji fali przepięciowej w typowych stacjach GIS. Zaprezentowano możliwość zapewnienia dodatkowej ochrony przeciwprzepięciowej poprzez ograniczenie maksymalnej wartości przepięć za pomocą filtru L-C. Proponowane rozwiązanie może być użyte jako alternatywne lub spełniające dodatkową ochronę przeciwprzepięciową. Symulacje przeprowadzono przy użyciu programów MATLAB i ATP/EMTP.
EN
Increasing power demand in China requires an efficient and reliable transmission system at highest voltage levels of 1100 kV AC. The paper presents measurement and simulation results performed for UHV disconnector testing in demonstration pilot project in China. Very Fast Transient Overvoltages impact on the disconnector design is investigated. A new approach of Trapped Charge Voltage analysis is presented wchich allows one to select the design optimized for more realistic calculation of overvoltages due to the disconnector operations.
PL
Rosnące zapotrzebowanie na moc elektryczną w Chinach skutkuje ciągłym podwyższaniem napięć przesyłowych w celu ograniczenia strat mocy. W gazowych rozdzielnicach najwyższych napięć istotnym zagadnieniem jest analiza przepięć spowodowanych operacją odłącznika. W artykule przedstawiono wyniki pomiarów i symulacji przeprowadzonych w układzie próby typu odłącznika w celu ograniczania przepięć poprzez zmianę prędkości rozchodzenia się styków odłącznika.
EN
This paper presents a new impedance-based fault location algorithm. Unsynchronised measurements of voltages and currents from two ends of a line are utilised as the input data. The algorithm is formulated with use of the distributed parameter line model. Simultaneous usage of two kinds of symmetrical components for determining the synchronisation operator makes that the calculations are non-iterative. The presented example illustrates the validity of the delivered fault location algorithm and its high accuracy.
PL
W artykule przedstawiono nowy impedancyjny algorytm określania odległości do miejsca zwarcia. Niezsynchronizowane pomiary napięć i prądów z obu końców linii są użyte jako dane wejściowe. Algorytm został sformułowany z uwzględnieniem modelu linii o parametrach rozłożonych. Jednoczesne użycie dwóch rodzajów składowych symetrycznych do wyznaczenia operatora synchronizującego zapewnia to, że obliczenia są nieiteracyjne. Prezentowany przykład ilustruje właściwości algorytmu i jego dużą dokładność.
12
Content available remote Fault location on three-terminal lines associated with current differential relays
EN
This paper presents an algorithm for locating faults on three-terminal power lines for inspection-repair purposes. The presented method has been tested and evaluated with use of fault quantities obtained from versatile simulations of faults with the software ATP/EMTP package. Results of fault location for the sample faults are delivered and discussed. Fault location accuracy is evaluated and an effective procedure for indicating the faulted line section, i.e. selecting the valid subroutine which yields the result corresponding to the actual fault, is described.
PL
W artykule przedstawiony jest algorytm określania miejsca zwarcia w linii rozgałęzionej (z trzema odcinkami), który może mieć zastosowanie do celów inspekcyjno-remontowych. Analizę proponowanej metody przeprowadzono w oparciu o wyniki komputerowej symulacji rozpatrywanej sieci z użyciem programu ATP/EMTP. Przedstawiono i przeanalizowano rezultaty lokalizacji dla wybranych zwarć. Dokonano oceny dokładności lokalizacji zwarć oraz przedstawiono algorytm stosowany do wskazania sekcji linii ze zwarciem, tzn. wyboru obowiązującej procedury lokalizacji, a więc tej, która daje rezultaty odpowiadające rzeczywistemu zwarciu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.