Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The high performance liquid chromatographic (HPLC) method was developed for the combined estimation of sodium alginate and pectin in raft forming pharmaceuticals on C18 column ZORBAX ODS (1.5 cm × 4.6 mm, 5 μm) with UV detection at 378 nm. The assay condition comprised of phosphate buffer pH 7.4 and methanol 60:40% v/v at a flow rate of 1.25 mL/min. The separation of sodium alginate and pectin with good resolution and a retention time less than 8 min was attained. The method was linear over a range of 200–800 μg/mL of sodium alginate and pectin. The regression values obtained from linearity curve of sodium alginate and pectin were 0.9993 and 0.9991, respectively. The retention time of sodium alginate and pectin was 3.931 and 7.470 min, respectively. The percent recovery of sodium alginate and pectin ranged from 94.2–98.5% and 92.1–98.4% respectively. The limit of detection (LOD) and limit of quantification (LOQ) of sodium alginate were found to be 2.443 and 3.129 μg/mL and the LOD and LOQ of pectin were 3.126 and 3.785 μg/mL, respectively. The resolution of sodium alginate and pectin was found in the range of 1.03–1.89 and 1.10–1.91, respectively. This method has been successfully applied to analyze the concentrations of sodium alginate and pectin in raft forming drug delivery systems.
EN
A sensitive, inexpensive high-performance liquid chromatography–ultraviolet detection (HPLC–UV) method has been developed and validated for the simultaneous monitoring of pantoprazole sodium sesquihydrate (PSS) and domperidone maleate (DM) in rabbit plasma on a C18 column with UV detection at 285 nm. Box–Behnken design was used with 3 independent variables, namely, flow rate (X1), mobile phase composition (X2), and phosphate buffer pH (X3), which were used to design mathematical models. Response surface design was applied to optimize the dependent variables, i.e., retention time (Y1 and Y2) and percentage recoveries (Y3 and Y4) of PSS and DM. The method was sensitive and reproducible over 1.562 to 25 μg/mL. The effect of the quadratic outcome of flow rate, mobile phase composition, and buffer pH on retention time (p ˂ 0.001) and percentage recoveries of PSS and DM (p = 0.0016) were significant. The regression values obtained from analytical curve of PSS and DM were 0.999 and 0.9994, respectively. The percentage recoveries of PSS and DM were ranged from 94.5 to 100.41% and 94.77 to 100.31%, respectively. The developed method was applied for studying the pharmacokinetics of PSS and DM. The Cmax of test and reference formulations were 48.06 ± 0.347 μg/mL and 46.31 ± 0.398 μg/mL for PSS, and 15.11 ± 1.608 μg/mL and 12.06 ± 1.234 μg/mL for DM, respectively.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.