Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
According to the theory of high refractive index of metamaterials, a composite structure of metal dielectric grating was designed to achieve high refractive index in infrared band. Based on the S-parameter inversion algorithm, we extracted the effective permittivity, the effective permeability, and the effective refractive index of the designed metamaterial. By changing the geometric parameters of the composite grating metamaterial structure, the effective refractive index of the designed metamaterial reaches more than 8.0 at the infrared resonance frequency. This is a high refractive index that many natural materials cannot achieve. It is noteworthy that the metamaterial structure has obvious polarization sensitivity. The metamaterial structure has both high refractive index and wideband zero refractive index properties when different polarized light is incident. At the same time, we further investigate the influence of metamaterial geometric parameters on the effective refractive index of metamaterials. Also, we propose a double grating metamaterial structure to obtain more degrees of freedom of metamaterial on the effective refractive index.
EN
Ventilation rate is a physical index that is strictly controlled during cigarette manufacturing because an abnormal ventilation rate can affect the release of mainstream smoke, tar, and other components harmful to human health. Therefore, the standard rod is used for measuring the ventilation rate, which necessitates accurate and effective periodic inspections. In this study, we designed and built a set of special tobacco ventilation rate standard rods to assess the standard device during its verification period and used a digital thermal flowmeter as the flow standard.We determined the micro-pressure adjustment interval through fluid simulation, and conducted an experimental verification based on the simulation results. At the adjustment point where the differential pressure value was 0 Pa, the period verification device was tested under the standard values of 27.38%, 58.83%, and 71.95%. The results show that the measurement errors of the device are -0.42%, 0.55%, and -0.13% respectively, which all meet the verification regulation requirements and indicate that the device is applicable in practical situations.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.