EN
Renewable energy power plants such as Mini Hydro Power Plants are currently being developed in Indonesia to fulfill electrical energy. Generally, the location of the Mini Hydro Power Plant (MHPP) far from the load center, and it requires a long electricity network so it is necessary to know the optimal position when connecting to a 20 kV distribution system. The technical and economic approach is carried out on the interconnection of the MHPP to the 20 kV distribution system. One thing that needs to be added to the selection of connection point locations is the environmental criteria that are intended to reduce GHG emissions by reducing the use of oil-fired plants such as Diesel Power Plants. Because sometimes the decision to choose the location of the generator connection point is technically and economically more optimal than other locations, but from an environmental perspective it is less than optimal compared to other locations. As explained in the decision making of the Rongkong MHPP which is directly connected to Masamba which can reduce the power capacity of the Cakaruddu Diesel Power Plant (Diesel-PP) maximally, even though the connection investment costs are more expensive than the closest location to the Diesel-PP.
PL
W Indonezji trwają prace nad budową elektrowni wykorzystujących energię odnawialną, takich jak mini elektrownie wodne, które mają dostarczać energię elektryczną. Generalnie lokalizacja Mini-Elektrowni Wodnej (MHPP) z dala od centrum obciążenia wymaga długiej sieci elektroenergetycznej, dlatego konieczna jest znajomość optymalnego położenia przy podłączaniu do systemu dystrybucyjnego 20 kV. Do wyboru lokalizacji przyłącza należy dodać kryteria środowiskowe, które mają na celu redukcję emisji gazów cieplarnianych poprzez ograniczenie wykorzystania elektrowni opalanych olejem, takich jak elektrownie Diesla. Czasami decyzja o wyborze lokalizacji punktu przyłączenia generatora jest technicznie i ekonomicznie bardziej optymalna niż inne lokalizacje, ale z punktu widzenia ochrony środowiska jest mniej niż optymalna w porównaniu z innymi lokalizacjami. Jak wyjaśniono w procesie decyzyjnym Rongkong MHPP, który jest bezpośrednio połączony z Masamba, co może maksymalnie zmniejszyć moc elektrowni Diesla Cakaruddu (Diesel-PP), mimo że koszty inwestycji w przyłączenie są wyższe niż lokalizacja najbliższa Diesel-PP.
EN
This paper presents an optimal planning for the configuration of a hybrid microgrid generating system based on the results of renewable energy potentials, which are photovoltaic (PV), wind turbine (WT), micro-hydro (MH) and batteries. Battle Star Galactica Starcraft Particle Swarm Optimization (BSG-Starcraft PSO) algorithm is used to determine the optimal generation size based on the local energy potential. The case study is located in an isolated area, namely Tangkeno area of Kabaena Island, Bombana Regency, Southeast Sulawesi, Indonesia which is used to verify the proposed method. The optimization results for this study are number of wind turbine (WT) required is 27 units with capacity of 180 Watt each and total capacity of 4.86 kW the number of solar panel (PV) needed is 231 units with capacity of 195 Watt each and total capacity of 44.85 kW. Hence the total capacity for renewable energy generation is 49.73 kW. The results of the comparison between the BSG-Starcraft PSO algorithm and PSO showed that by using the BSG-Starcraft PSO provided optimal and faster solution compare to PSO.
PL
W artykule przedstawiono optymalne planowanie konfiguracji hybrydowego systemu wytwarzania mikrosieci w oparciu o wyniki potencjałów energii odnawialnej, którymi są fotowoltaika (PV), turbina wiatrowa (WT), mikrohydro (MH) i akumulatory. Algorytm Battle Star Galactica Starcraft Particle Swarm Optimization (BSG-Starcraft PSO) służy do określenia optymalnej wielkości generacji w oparciu o lokalny potencjał energetyczny. Studium przypadku znajduje się na odosobnionym obszarze, a mianowicie obszarze Tangkeno na wyspie Kabaena, Bombana Regency, południowo-wschodnie Sulawesi, Indonezja, który służy do weryfikacji proponowanej metody. Wyniki optymalizacji dla tego badania to liczba wymaganych turbin wiatrowych (WT) to 27 jednostek o mocy 180 W każda i łącznej mocy 4,86 kW liczba potrzebnych paneli słonecznych (PV) to 231 jednostek o mocy 195 W każda i całkowita moc 44,85 kW. Stąd łączna moc wytwarzania energii odnawialnej wynosi 49,73 kW. Wyniki porównania algorytmu BSG-Starcraft PSO i PSO wykazały, że zastosowanie BSG-Starcraft PSO zapewniło optymalne i szybsze rozwiązanie w porównaniu do PSO.
EN
The Government of Indonesia is accelerating the use of new and renewable energy for electricity supply. The use of renewable energy also intends to reduce greenhouse gas emissions. Electricity generated will be connected in a transmission and distribution network on the grid that is available to be distributed to consumers. Renewable energy sources, especially the Mini Hydro Power Plant (MHPP) with a capacity of 1 - 10 MW, are located in rural areas far from the load center. Long distances will result in reduced voltage and power losses in the power distribution system. Therefore the connection of renewable energy plants especially MHPP should not have a negative impact on the existing electricity system. In general, the connection is declared successful if the voltage drop is in the range between a maximum of +5% and a minimum of -10% of nominal voltage, small power losses, and short circuit current is not large. The MHPP connection must be carried out with a technical and economic approach when making decisions on determining the connection point. Because sometimes the decision to choose a connection location is technically fulfilling but economically it does not meet, on the contrary, there is also technically not good even though it is economically feasible, or both are not feasible. As shown in the decision making for the Bontosalama MHPP which is directly connected to the Sinjai substation although investment is expensive it is not constrained from the technical limitations of the Sinjai system.
PL
Wytworzona energia elektryczna jest podłączona do sieci przesyłowej, która jest dostępna do dystrybucji wśród odbiorców. Odnawialne źródła energii, zwłaszcza mini elektrownia wodna (MHPP) o mocy 1–10 MW, znajdują się na obszarach wiejskich z dala od centrum obciążenia. Duże odległości powodują zwiększenie strat napięcia i mocy w systemie dystrybucji energii. Podłączenie elektrowni odnawialnych, zwłaszcza MHPP, nie powinno mieć negatywnego wpływu na istniejący system elektroenergetyczny. Zasadniczo połączenie uznaje się za udane, jeśli spadek napięcia mieści się w przedziale od maksimum + 5% do minimum -10% napięcia nominalnego. Połączenie MHPP musi być wykonane z technicznym i ekonomicznym podejściem przy podejmowaniu decyzji o ustaleniu punktu przyłączenia. Ponieważ czasami decyzja o wyborze lokalizacji połączenia jest technicznie satysfakcjonująca, ale ekonomicznie nie spełnia, wręcz przeciwnie, nie jest również technicznie niedobra, nawet jeśli jest to ekonomicznie wykonalne lub oba są niewykonalne. Jak pokazano w procesie decyzyjnym dla Bontosalama w Indonezji MHPP, który jest bezpośrednio podłączony do podstacji Sinjai, chociaż inwestycja jest droga, nie jest ograniczona technicznymi ograniczeniami systemu Sinjai.
EN
The purpose of this study is to optimize the location and capacity of PV in the feeder distribution system 20 kV of Central Sulawesi, Indonesia. The proposed method uses the optimization method of development from the genetic algorithm, namely NSGA-II. Optimization is carried out in three scenarios by considering the value of the total active PV power capacity which produces the minimum active power loss and voltage deviation. The simulation result shows that the integration of PV-DG can improve drop voltage of distribution system performance due to load growth effect.
PL
Celem tego badania jest optymalizacja lokalizacji i wydajności PV w systemie dystrybucji zasilania 20 kV w środkowym Sulawesi w Indonezji. Proponowana metoda wykorzystuje optymalizację opartą na algorytmie genetycznym, mianowicie NSGA-II. Optymalizację przeprowadza się w trzech scenariuszach, biorąc pod uwagę wartość całkowitej mocy czynnej PV, która powoduje minimalne straty mocy czynnej i odchylenie napięcia. Wynik symulacji pokazuje, że integracja PV-DG może poprawić wydajność systemu dystrybucji ze względu na efekt wzrostu obciążenia.
EN
Electricity losses are very dependent on electric current and loss of the corona phenomenon. It is very clear that losses depend on network parameters, load behaviors and climatic factors. South Sulawesi is a tropical climate. This sector must be resistant to exposure to various factors of high tropical climate such as temperatures of 23.4 ⁰ C - 33.3 ⁰ C, sun irradiation that occurs more than 12 hours per day, relative humidity close to 100%, and average rainfall between 440-1322 mm . This climate factors will simultaneously transmit the transmission. This text aims to connect climate factors to achieve power losses on 275 kV transmission line in South Sulawesi. The results of this study found that temperature and duration of sun irradiation affected corona power losses on 275 kV transmission line in South Sulawesi.
PL
Straty elektryczne są bardzo zależne od prądu elektrycznego i zjawiska korony. Oczywiste jest, że straty zależą od parametrów sieci, obciążenia i czynników klimatycznych. South Sulawesi to tropikalny klimat. Sektor ten musi być odporny na działanie różnych czynników tropikalnych, takich jak temperatura 23  C - 33  C, promieniowanie słoneczne, które występuje więcej niż 12 godzin dziennie, wilgotność względna bliska 100%, a średnie opady wynoszą 440-1322 mm. Niniejszy artykułma na celu analizę czynników klimatycznych w celu uzyskania strat mocy na liniach przesyłowych 275 kV w Południowym Sulawesi. Wyniki adania pokazały, że temperatura i czas trwania promieniowania słonecznego wpłynęły na straty energii z wyładowań koronowych.