In the paper, there are presented a general description of the constructed measuring system 8AE-PD, the results of calibration of this system by the Hsu-Nielsen method as well as the testing of the measuring system during recording signals generated by Hsu-Nielsen sources in a steel plate and a modeled partial discharge (PD) source. There is also presented the methodology of investigations by the calibrated acoustic emission method. The results of analyses of PD signals coming from the modeled sources are given. In particular, there are described the properties of acoustic emission (AE) signals generated by the PDs as well as the dependencies of the peak-to-peak voltage Umm, the RMS voltage Urms and the descriptors of acronyms ADP and ADC on the apparent charge Q introduced by the modeled PD source. There are determined the limit values of the apparent charge Q introduced by the modeled PD source for which the recorded signal is identified as originating from the PDS.
PL
Tematyka artykułu dotyczy prowadzonych przez pracowników Politechniki Śląskiej badań i prac koncepcyjnych zmierzających do zaprojektowania oraz skonstruowania niskoszumnego przedwzmacniacza, przeznaczonego do współpracy z komputerowym systemem pomiarowym 8EA-WNZ, który służy do detekcji i lokalizacji wyładowań niezupełnych metodą emisji akustycznej w transformatorach elektroenergetycznych. Zasadniczym celem omawianych w artykule prac jest próba optymalizacji parametrów aktualnie wykorzystywanego przedwzmacniacza pomiarowego zbudowanego z zastosowaniem znanego układu INA110KP. W publikacji zaprezentowano wyniki badań wskazujące na możliwość opracowania nowego układu przedwzmacniacza o znacznie lepszych parametrach w stosunku do poprzednika. Zaprezentowano wybrane rozwiązania konstrukcyjne, które bazują na najnowszych scalonych przedwzmacniaczach pomiarowych opracowanych w 2012 roku przez firmę Analog Devices. Rezultatem przeprowadzonych prac było zbudowanie funkcjonalnego przedwzmacniacza napięciowego przeznaczonego do współpracy z systemem komputerowym 8EA-WNZ oraz czujnikami pomiarowymi serii WD oraz D9241A. Oferuje on w podstawowej wersji wzmocnienie rzędu 70 dB regulowane skokowo i pasmo przenoszenia od 15 kHz do 1,3 MHz.
EN
The subject of the article concerns investigations and conceptional works realized by scientific workers from Department of Optoelectronics Silesian University of Technology aimed at design and construct a low noise preamplifier assigned for collaboration with computer measuring system 8EA-PD which serves for detection and location of partial discharges by means of acoustic method within power transformers. The principal purpose of works presented in the article was optimization of parameters of the measuring preamplifier which is used at present and built on a base of well-known INA110KP integrated circuit.The publication contains investigation results which point out possibility to construct a new preamplifier with parameters considerably better than the predecessor. Chosen constructional solutions, based on the latest self-contained measuring preamplifiers, worked out at 2012 year by the firm Analog Devices, have been presented.The result of carried out works was construction of entirely functional voltage preamplifier assigned for collaboration with computer measuring 8EA-PD system as well as with measuring sensors of WD series and D9241A. It offers in its basic version amplification of 70 dB (regulated step by step) and transfer band from 15 kHz to 1.3 MHz.
PL
Przedstawiono zaprojektowany i zbudowany przez autorów komputerowy system pomiarowy dedykowany do lokalizacji i opisu wyładowań niezupełnych w transformatorach energetycznych olejowych metodą emisji akustycznej. System pomiarowy sygnałów emisji akustycznej posiada 8 torów pomiarowych i zapewnia monitorowanie sygnałów i rejestrację danych w czasie rzeczywistym w paśmie 20-1000 kHz w warunkach laboratoryjnych i rzeczywistych.
EN
The computer measuring system, designed and built by authors, dedicated for location and description of partial discharges within power oil transformers investigated by means of acoustic emission method is presented. The measuring system of acoustic emission is equipped with 8 measuring circuits and ensures monitoring of signals as well as registration of data in the real time within the band of 20-1000 kHz in laboratory and real conditions.
PL
Przedstawiono zaprojektowany i zbudowany przez autorów komputerowy system pomiarowy dedykowany do lokalizacji i opisu wyładowań niezupełnych w transformatorach energetycznych olejowych metodą emisji akustycznej. System pomiarowy sygnałów emisji akustycznej posiada 8 torów pomiarowych i zapewnia monitorowanie sygnałów i rejestrację danych w czasie rzeczywistym w paśmie 20-1000 kHz w warunkach laboratoryjnych i rzeczywistych. Przedstawiono autorski system analizy obejmujący podstawową i zaawansowaną analizę zarejestrowanych danych. W ramach zaawansowanej analizy danych obliczane są zdefiniowane przez autorów deskryptory, wyznaczane są mapy deskryptorów na ścianach bocznych transformatora i dokonywana jest lokalizacja źródeł wyładowań niezupełnych autorską metodą stopnia zaawansowania sygnału.
EN
Presented is designed and built by the authors a computerised measurement system dedicated to localization and description of partial discharges in power oil transformers with the use of acoustic emission method. The acoustic emission signals measurement system has 8 slotted lines and ensures monitoring of signals and real time data registration in 20-1000 kHz frequency band in both laboratory and real conditions. Presented is the author’s analysing system covering basic and advanced analyses of registered data. In the frames of the advanced data analysis the defined by the authors descriptors are calculated, descriptor maps are determined on transformer side walls as well as localization of partial discharges sources is made using the authors’ method of signal advancement level.