Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper describes the model tests conducted in the Wind Engineering Laboratory of the Cracow University of Technology aimed at determining the shape coefficients of snow load on high-rise buildings of The Warsaw Hub. The shape coefficient was measured at two different situations: snow precipitation and its subsequent redistribution. The model tests were conducted independently for rooftops and terraces in the scale of 1:120 and for the neighbouring area of the buildings in the scale of 1:300. The results allowed for creation of snow shape coefficient maps on the investigated areas both for snow precipitation and redistribution for the use of designers, constructors and architects.
PL
Jedna z najsilniejszych odnotowanych nawałnic miała miejsce 11 i 12 sierpnia 2017 r. nad terenem środkowej Polski. Na stacji meteorologicznej Elbląg–Milejewo odnotowano rekordową do tej pory na terenie Polski prędkość porywu wiatru w tej klasie zjawisk meteorologicznych, wynoszącą ponad 42 m/s. Ze względu na obszar oddziaływania, skalę zniszczeń, długość trwania i prędkości podmuchów nawałnicę można sklasyfikować jako derecho, czyli długotrwałą gwałtowną burzę wiatrową.
EN
On 11th and 12th of August 2017 central Poland was subject to one of the most devastating storms ever recorded in this area. At the weather station in Elbląg-Milejewo a record gust speed in Poland history has been recorded for this class of meteorological phenomena that exceeded 42 m/s. Considering the affected area, extent of damages, duration and gust speeds, the storm can be classified as a derecho, a sustained torrential gusty wind storm.
PL
Przedstawiono wyniki serii badań niepodatnego modelu wiązki przewodów linii energetycznej, przeprowadzonych w celu wyznaczenia współczynników aerodynamicznych Cx, Cy i Cm w wybranych przypadkach ośnieżenia, oblodzenia i oszronienia przewodów. Określono współczynniki aerodynamiczne przewodów nawietrznych i zawietrznych, a także wzajemną interferencję aerodynamiczną przewodów linii napowietrznych.
EN
The subject of this paper is the set of tests, performed on rigid aerodynamic model of wire bundle, that aimed at determination of aerodynamic coefficients Cx, Cy and Cm for selected cases of snow, ice and frost covers of wires. Both windward and leeward wires were taken into consideration. On this basis, aerodynamic interferences of overhead line wires was determined.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.