Content available E.Cam DUET gamma camera model validation in GATE
EN
Monte Carlo simulations are more and more popular trend in nuclear medicine imaging. They were also widely used in radiotherapy and brachytherapy with use of more general simulation software. GATE (Geant4 Application for Tomographic Emission) is a platform developed on general Monte Carlo code designed for simulating and tracking the passage of particles through matter (Geant4) but is specifically designed for nuclear medicine imaging purposes. The aim of this work was to create and validate a model of specific gamma-camera (E.Cam DUET), used in our department, for further use in image analysis and dosimetry field, with GATE simulation platform. We have modeled in first step a point source in the air in three configurations of gamma camera (without collimator, with low-energy high-resolution (LEHR) collimator and with high-energy (HE collimator)), then we have created a phantom with three spherical sources of different sizes but with the same concentration of the radiopharmaceutical. Simulation results were compared to the measured values of the energy spectrum and images obtained on the detectors, and show a good agreement for the point source experiments and revealed some differences for the phantom studies. This results shows that some additional tests and refinements are required but also allows us to study the image degrading quality factors, such as septal penetration and to work towards eliminating them from the pictures.
EN
In this paper, the thermal and epithermal neutron fluence distributions in the vicinity of the Primus Siemens accelerator are presented. The measurements were carried out by the use of the neutron activation method for 15 MV X-rays and electron beams of 18 MeV and 21 MeV. From the radiation safety point of view for the hospital personnel, it is important to know the thermal and epithermal neutron fluence distribution in the vicinity of the accelerator because the neutrons interacting with atoms of a medium by various processes induce the activity of objects (accelerator, other apparatus etc.) and walls in the treatment room. The thermal and epithermal neutron capture, particularly, in high atomic number materials of the accelerator head can be a significant source of gamma radiation and it has to be taken into account for estimation of the work safety of the personnel. Values of the neutron fluence were normalized to the maximum photon (or electron) dose Dmax,gamma (e) measured at the central axis of therapeutic X-ray (or electron) beam in a water phantom. The thermal neutron fluences measured during the 15 MV X-ray emission varied between 1.1 × 10 5 n ź cm 2ź Gy -1 and 4.4 × 10 5 n ź cm -2ź Gy 1 whereas the epithermal neutron fluences ranged from 0.2 × 10 5 n ź cm 2ź Gy- 1 to 1.8 × 105 n ź cm -2ź Gy -1. In the case of electron beams, the neutron fluence measurements were performed only at the isocentre. The obtained thermal and epithermal neutron fluences were 1.2 × 10 4 n ź cm -2ź Gy -1 and 0.6 × 10 4 n ź cm -2ź Gy -1, respectively, for the 18 MeV electrons. In the the case of the 21 MeV electron beams the thermal neutron fluence was -2.0 × 10 4 n ź cm -2ź Gy -1 whereas the epithermal neutron fluence was 0.8 × 10 4 n ź cm -2ź Gy-1.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.