The aim of the paper is to analyse the friction forces in joints of pressed platform flat and transverse bars. Actual friction forces could have been determined based on the diagrams of force changes in the process of removal of a transverse bar from a groove in a flat bar. The paper presents diagrams of pressing and removing forces of transverse bars. The measurement of forces has been done for three distances between grooves in flat bars, i.e. 11.1 mm, 22.2 mm, and 33.3 mm. A significant variation of force values has been observed during both pressing and the extrusion of the bars. It has been assumed that one of the main causes of variation is the groove geometry. On the groove, walls there are stamp material shearing areas and breaking areas. The shearing area determines the friction force values.
PL
Celem pracy jest analiza sił tarcia w połączeniach płaskowników nośnych i poprzecznych krat prasowanych. Rzeczywiste siły tarcia można było określić z wykresów zmian sił w procesie usuwania płaskownika poprzecznego z rowka w płaskowniku nośnym. W pracy przedstawiono wykresy sił wprasowywania i usuwania płaskowników poprzecznych. Pomiaru sił dokonano dla trzech odległości rowków w płaskownikach nośnych, tj. 11,1 mm, 22,2 mm i 33,3 mm. Stwierdzono duże zróżnicowane wartości sił zarówno podczas wprasowywania, jak i wyciskania płaskowników. Przyjęto, że jedną z głównych przyczyn powstających różnic jest geometria rowków. Na ściankach rowków występuje strefa ścinania materiału stemplem oraz strefa pękania. O wartościach sił tarcia decyduje strefa ścinana.
PL
W artykule przedstawiono działanie instalacji grzewczej w Centrum Dystrybucji IKEA Jarosty - II etap. Podano założenia projektowe, wyjściowy schemat ideowy oraz zasadę działania układu. W budynku źródłem ciepła są 4 pompy ciepła o łącznej mocy 929 kW oraz kocioł szczytowy o mocy 895 kW. Źródłem dolnym dla pomp ciepła są dwie studnie głębinowe o łącznej wydajności 240 m3/h. W artykule przedstawiono wyniki pomiarów zużycia energii elektrycznej oraz wyprodukowanego ciepła w sezonie 2004-2005. Rzeczywiste współczynniki COP pomp ciepła wynoszą 3,6-3,9 co spełnia założenia przyjęte przy projektowaniu systemu. Artykuł zawiera również spostrzeżenia dotyczące bieżącej obsługi i użytkowania systemu.
EN
Heating system in IKEA Distribution Centre Jarosfy is described in the paper. Brief foredesign, schematic diagram and principle of operation are presented. Heat source consists of 4 heat pumps (929 kW) and gas boiler (895 kW). Groundwater from two deep-well pumps is used as a lower source (total flow 240 m3/h). In the paper, results of measurements of energy consumption and producted heat energy in the 2004-2005 heating period are presented. Real COP coefficients or heat pumps eaual 3,6-3,9. This values fulfil values assumed during trie design process. In the paper observations concerning current system service and maintenance are also presented.
PL
W obiekcie dystrybucyjnym IKEA zastosowano do celów grzewczych pompy ciepła korzystające z odwiertów wykonanych dla potrzeb instalacji p.poż. Dzięki temu wyeliminowano emisję spalin do atmosfery oraz zmniejszono koszty eksploatacji systemu grzewczego.
PL
W artykule opisano instalację grzewczą wykonaną w Regionalnym Centrum Dystrybucji w Jarostach. Przedstawiono założenia projektowe, wyjściowy schemat ideowy oraz zasadę działania układu. W budynku źródłem ciepła są cztery pompy ciepła o łącznej mocy 929 kW oraz kocioł szczytowy o mocy 895 kW. Źródłem dolnym dla pomp ciepła jest woda z dwóch studni głębinowych o łącznej wydajności 240 m3/h.
EN
Heating system in IKEA Distribution Centre Jarosty is described in the paper. Brief foredesign, schematic diagram and principle of operation are presented. Heat source consists of 4 heat pumps (929 kW) and gas boiler (895 kW). Groundwater from two deep-well pumps is used as a lower source (total flow 240 m3/h).
PL
W pracy przedstawiono syntetyczne ujęcie obecności bezpośrednich inwestycji za-granicznych (BIZ) w polskiej gospodarce w latach 90., wykorzystując kryterium sekto-rowe, tj. rozmieszczenie BIZ w poszczególnych gałęziach gospodarki. Ukazano także ko-rzyści dla Polski płynące z inwestycji zagranicznych zarówno w aspekcie mikroekono-micznym jak i makroekonomicznym.
EN
In the paper, inflow of foreign direct investments (FDI) to Poland in the years 1990-1998 was presented, where mainly a sector criterion was used i.e. location of FDI in particular branches of the economy. The author also pointed out the main advantages of foreign investments for Polish econo-my in the micro- and macro-economical aspect.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.