Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In a percutaneous pedicle screw surgery the surgeon is faced with huge challenges because he has no direct view on the operating field. The screw positions and the required rod dimensions for the stabilizing connection are hard to define. In this paper a new method for a percutaneous pedicle screw surgery is described to record the positions of three pedicle screws with help of a mobile localizing system with passive markers and a tablet computer. The presented system calculates the required rod length and rod radius. The procedure is more convenient than mechanical measuring systems and it works without radiation load of the patient. The system is tested with an in-vitro test arrangement and first results are very promising with an accuracy of ±2 mm for the rod length.
PL
Dużym problemem dla chirurgów w zabiegach nieinwazyjnej chirurgii śrub pedikularnych jest brak oglądu na pole operacyjne. Z tego powodu określenie pozycji poszczególnych śrub oraz wymaganej długość prętu stabilizacyjnego może nastręczać trudności. W niniejszym artykule zaprezentowano nową metodę rejestracji pozycji śrub pedikularnych z wykorzystaniem pasywnych markerów optycznych, mobilnego systemu nawigacyjnego, oraz tabletu. Zaprezentowane rozwiązanie pozwala na obliczenie wymaganej długości oraz krzywizny pręta pedikularnego. Opisywana metoda jest wygodniejsza niż pomiar z wykorzystaniem systemów mechanicznych oraz nie wymaga naświetlenia pacjenta promieniowaniem rentgenowskim. Testy metody przeprowadzone w środowisku in-vitro wykazały dokładność pomiaru długości pręta stabilizacyjnego na poziomie ±2 mm co wydaje się być bardzo obiecującym rezultatem.
2
EN
This article describes a cost-effective, ultrasound-based measuring system for the Pelvic Tilt. The system allows the acquisition of the exact pelvic orientation for each individual patient both pre- and postoperatively. A major advantage of this system is that measurements may be recorded for any patient posture e.g. standing or sitting. Instead, the current state-of-the-art is based on CT or MRI tomography where patients are required to be in a lying position. First experimental results with an artificial hip reference model show very accurate results with maximum deviations of ±1 degree, and ±1.4 degree in different measurement scenarios.
PL
W pracy opisano niskokosztowy system pomiaru kąta nachylenia płaszczyzny miednicy oparty na urządzeniach mobilnych. System pozwala na pomiar kąta płaszczyzny miednicy dla indywidualnego pacjenta, zarówno przed jak i pooperacyjnie. Główną zaletą opisywanego systemu jest możliwość dokonywania pomiarów dla każdej postawy pacjenta (np. siedzącej lub stojącej) w odróżnieniu od obecnego stanu techniki, gdzie pomiar taki z wykorzystaniem tomografii komputerowej bądź rezonansu magnetycznego może być dokonany jedynie w pozycji leżącej. Pierwsze testy przeprowadzone na sztucznym modelu miednicy dały bardzo dobre wyniki z odchyleniem standardowym wynoszącym ±1 stopień oraz ±1,4 stopnia w innych scenariuszach testowych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.