Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 16

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Growing popularity of distributed generation is drawing special attention to communication technologies in smart power grids. This paper provides a detailed overview of the communication protocols utilized in the modern distributed grid laboratory. It describes both wired and wireless technologies used in Smart Grid and presents the remote operation of switching the subsystem from grid mode to island mode operating under nominal conditions. It shows the duration of power outages during a transfer to island mode with diesel generator running on idle - which simulates planned islanding and diesel generator stationary, which simulates unplanned islanding. Latency between registration of disturbance and executing control command is measured. The results obtained are compared with current legislation. The consequences to the power system that are possible in both scenarios are highlighted. Obtained results and description of the communication technologies can be useful for the design of distributed power grids, island-mode power grids, and Smart Grids, as well as for further research in the area of using combustion fuel generators as a primary power supply in the microgrid.
PL
Interaktywność to jedno z najważniejszych wyzwań rozwoju nowoczesnych sieci elektroenergetycznych. Tak, również tych w Polsce, wciąż w znakomitej większości bazujących na konwencjonalnych elektrowniach, a jednak stających w obliczu systematycznego rozwoju instalacji prosumenckich, rozproszonych źródeł odnawialnych. Konieczność reagowania na zmienne wymagania użytkowników w zakresie popytu i podaży mocy w systemie sieci dystrybucyjnych to realna perspektywa dla sieci elektroenergetycznych, otwierająca nowe kierunki rozwoju, ale też stawiająca wyzwania technologiczno-organizacyjne.
3
Content available remote Energy Sector of Pakistan – A Review
EN
Any country’s socio-economic growth is interlinked with number of factors, some of more significance with devastating impact whereas the others with very less impact. Amongst all such factors, energy is one of the major player in economic growth of a country, now a days as the energy sector drives the engine of progress, growth, and development in industrial, agricultural, and defense sectors, adding the impact to domestic consumers. The purpose of the study is to discuss the Pakistan’s current energy crisis which is getting worse and worse by everyday passing. Mainly the official data, along with the research work of scholars, international data and some raw data, all are collectively used to understand and convey a clear picture. This study would lay a basis for future studies which will uncover the solution to take the energy sector of Pakistan out of energy crisis.
PL
Na rozwój socjoekonomiczny kraju wpływa, w róznym stopinu, wiele czynników. Pośród nich jednym z najważniejszych jest energia. ˙ Dostępność energii wpływa na przemysł, rolnictwo, sektor obronny oraz życie codzienne mieszkańców kraju. W niniejszym artykule opisano kryzys energetyczny w Pakistanie. Na podstawie danych oficjalnych i przeglądu literaturowego oceniono stan energetyki w Pakistanie. W pracy zaproponowano tez możliwe drogę rozwoju sektora energetycznego Pakistanu
4
Content available remote A review of electricity and renewable energy sectors status and prospect in Jordan
EN
In Jordan, there are many extensive challenges that the country faces against the national economy growth. This is mainly because Jordan has limited primary energy resources and imports more than 90% of natural gas and crude oil from neighboring countries which negatively affect its economy. However, the geographical location of Jordan is one of the benefits that make the country rich in renewable energy resources particularly solar and wind energy resources. Therefore, to fulfill the high growth of electricity demand in the coming years; Jordan is working on increasing the contribution percentage of renewable energy resources in the total energy mix. In this paper, the status of the electricity supply system and renewable energy resources in Jordan are discussed. Furthermore, the investigation of implementing the prospect scenario of increasing the share of electric generation from renewable energy resources shows that the generated power from solar and wind are significantly enhancing the national economy growth.
XX
W Jordanii istnieje wyzwan wpływających na rozwój gospodarczy tego kraju. Jednym z takich wyzwan jest brak pierwotnych źródeł energii, co zmusza kraj do importu 90% energii, tj. ropy i gazu, od krajów osciennych. Geografia Jordanii pozwala jednak na duży rozwój energetyki ˙ odnawialnej, w szczególności energetyki opartej na energii słońca i wiatru. Ważnym elementem zapewnienia podaży na rosnący popyt na energię jest więc rozwój energetyki odnawialnej. W artykule omawiany jest obecny stan energetyki Jordanii oraz omawiany jest rozwój energetyki odnawialnej w miksie energetycznym tego kraju.
PL
Operatorzy elektroenergetycznych systemów dystrybucyjnych w Polsce zainstalowali w swoich sieciach kilkadziesiąt tysięcy bilansujących liczników energii elektrycznej wyposażonych, zgodnie z wymaganiami Urzędu Regulacji Energetyki, w funkcje pomiaru wskaźników jakości dostawy energii elektrycznej. Liczniki te oferują nowe możliwości oceny jakości napięcia oraz diagnostyki sieci dystrybucyjnych, będąc źródłem istotnego wolumenu danych pomiarowych. Artykuł prezentuje możliwości wykorzystania wyników pomiarów agregowanych w okresach 10minutowych, pochodzących z rozproszonego systemu pomiarowego (składającego się z dużej liczby liczników i i małej liczby analizatorów) w lokalizacji dominujących źródeł zaburzeń w elektroenergetycznej sieci dystrybucyjnej.
EN
In recent years, electricity distribution system operators in Poland have installed tens of thousands of balancing electricity meters, in accordance with the requirements of the Energy Regulatory Office, with the function of measuring the quality of electricity supply indicators. These meters offer new possibilities in the assessment of functioning and diagnostics of power distribution systems. The article presents the possibility of using aggregated 10-minute power quality measurement data from dispersed electricity meters to locate dominant sources of disturbances in the power distribution network.
PL
W polskich zakładach górniczych napędy maszyn wyciągowych napędzane są głównie przez silniki obcowzbudne prądu stałego. Regulacja prędkości takiego silnika odbywa się dzięki zastosowaniu przekształtników statycznych. Oprócz niewątpliwych zalet tego typu napędu, coraz częściej dostrzegany jest negatywny wpływ tego typu napędów na sieci elektroenergetyczne kopalń. Dlatego poszukuje się możliwości ograniczenia negatywnych skutków pracy takiego napędu przez zastosowanie m.in. przekształtników złożonych. W artykule przedstawiono analizę doboru liczby pulsów układu przekształtnikowego maszyny wyciągowej pod kątem sprawności układu oraz jego oddziaływania na sieć zasilającą.
EN
In Polish mining plants the drives of hoisting machines are mainly made by separately excited DC motors. The speed of such a motor is regulated by the use of static converters. In addition to the unquestionable advantages of this type of drive, its negative impact on the power networks of mines is increasingly being noticed. Therefore, it is sought to limit their negative effects by using, e.g. complex converters. In this article the selection of the number of pulses of the hoisting machine converter system in terms of system efficiency and its impact on the supply network is presented.
PL
W artykule zaproponowano zastosowanie oprogramowania OpenDSS do komputerowej symulacji pracy sieci dystrybucyjnej w celu estymacji wartości skutecznej napięcia w nieopomiarowanych punktach sieci. Zaproponowane narzędzie umożliwia wsparcie operatorów systemów dystrybucyjnych w monitorowaniu i diagnostyce pracy ich sieci. Wyniki pomiarów oraz symulacji zostały porównane dla wybranego obszaru systemu dystrybucyjnego na poziomie średniego napięcia. Na podstawie zarejestrowanych danych pochodzących z elektrowni fotowoltaicznej wykonano symulację wpływu przyłączenia oze do badanego fragmentu sieci.
EN
The article proposes the use of OpenDSS software for computer simulation of distribution network operation in order to estima te the RMS voltage at unmetered network points. The proposed tool enabled the support of distribution system operators in monitoring and diagnostics of their network operation. The results of measurements and simulations of the selected area of the distribution system at the medium voltage level were compared. Based on the recorded data from the solar farm, a simulation of the impact of connecting renewable energy sources to the tested part of the network was made.
PL
W artykule przedstawiono prace badawczo-rozwojowe w obszarze monitorowania jakości dostawy energii elektrycznej (JDEE). Działania realizowane są w ramach projektu NCBR. Obecnie realizacji podlega etap I projektu. Dotyczy pomiarów i rejestracji oraz analizy JDEE z uwzględnieniem rozszerzonego pasma do 150 kHz z wykorzystaniem techniki synchrofazorowej w sieciach dystrybucyjnych. Końcowym rezultatem projektu jest opracowanie i zbudowanie nadrzędnego systemu, integrującego różnego typu dane z różnych podsystemów.
EN
The article presents research and development works in the area of monitoring of power quality. The activities are carried out within the NCBR project. Currently, stage I of the project is being implemented. It concerns measurements and recordings as well as analysis of the power quality, including the extended band up to 150 kHz (supraharmonics) and synchrophasors in distribution networks. The final result of the project is the development and build of a superior system, integrating a wide range of data from several subsystems.
9
Content available remote Monitoring of electric arc furnace supply voltage frequency using phasor analysis
EN
This paper presents the results of measurement experiment conducted in the operating steel plant. Frequency analysis of measured signals revealed an interesting phenomenon, as it happened that after switching off the electric arc furnace, the frequency of the supplying voltage and current increased slightly instead of decreasing, as we would normally expect. This abnormal frequency behaviour was identified by phasor analysis and also confirmed by the DTFT (Discrete Time Fourier Transform) analysis, and the MatrixPencil analysis.
PL
Artykuł prezentuje wyniki eksperymentu wykonanego w hucie stali. Analiza częstotliwości ujawniła ciekawe zjawisko, w którym po wyłączeniu pieca łukowego częstotliwości napięcia i prądu w wewnętrznej części huty zmniejszyła się zamiast zwiększyć, jak można by się spodziewać. To nieoczekiwane zjawisko zostało zarejestrowane z pomocą PMU i potwierdzone przez transformację Fouriera dla sygnałów dyskretnych oraz analizę MatrixPencil.
EN
The paper presents a comparison of methods for assessing individual harmonic and voltage fluctuations emissions, based on aggregated 10-minute values. IEC technical reports suggest that measurements of the aggregated 10-minute RMS current and voltage, used to assess individual harmonic emissions, should be performed for a sufficiently long time - a minimum of a week. The work used real measurements made in the distribution network. The obtained results confirm the legitimacy of using 10-minute data to assess the emissions of the analysed disturbances.
PL
W pracy przedstawione zostało porównanie metod oceny indywidualnej emisji harmonicznych i wahań napięcia, na podstawie zagregowanych 10 minutowych wartości. Zaprezentowane przykłady wykorzystania opisanych metod bazują na pomiarach wykonanych w sieci dystrybucyjnej. Otrzymane wyniki potwierdzają zasadność wykorzystania danych 10-minutowych do oceny emisji analizowanych zaburzeń.
PL
W polskich zakładach górniczych napędy maszyn wyciągowych realizowane są głównie w oparciu o silniki prądu stałego. W artykule przedstawiono analizę doboru liczby pulsów układu przekształtnikowego maszyny wyciągowej pod kątem sprawności układu oraz jego oddziaływania na sieć zasilającą.
EN
The drive systems of hoisting machines in Poland are based on the separately excited DC motors. The motors are supplied by power electronic converters. Almost all machines are built in a 12-pulse configuration. The article explains whether it is technically and economically reasonable to manufacture multi-pulse systems (with a number of pulses greater than 12).
PL
W artykule przedstawiono prace badawczo-rozwojowe w obszarze monitorowania jakości dostawy energii elektrycznej oraz bilansowania mocy i energii podjęte przez Enea Operator, we współpracy z Akademią Górniczo-Hutniczą. Działania realizowane są w ramach projektu NCBR. Obecnie realizacji podlega etap I projektu. Dotyczy pomiarów i rejestracji oraz analizy jakości dostawy energii elektrycznej z uwzględnieniem rozszerzonego pasma do 150 kHz oraz z wykorzystaniem techniki synchrofazorowej w sieciach dystrybucyjnych. Końcowym rezultatem projektu jest opracowanie i zbudowanie nadrzędnego systemu, którego zadaniem będzie integracja danych z mobilnych i stacjonarnych analizatorów, synchrofazorów, systemów prognozowania produkcji energii z rozproszonych źródeł w celu ich analizowania, raportowania oraz bilansowania mocy i energii.
EN
The article presents research and development works in the area of monitoring the power quality and power and energy balancing carried out by Enea Operator, in cooperation with the AGH University of Science and Technology. The activities are implemented as part of the NCBR project. Currently, stage I of the project is being implemented. It concerns measurements and registration as well as analysis of the power quality, including the extended band up to 150 kHz and using synchrophasor technology in distribution networks. The final result of the project is the development and build of a superior system whose task will be the integration of data from mobile and stationary analyzers, synchrophasors, energy forecasting systems from distributed generation for their analysis and reporting as well as power and energy balancing.
PL
Artykuł prezentuje wyniki eksperymentu wykonanego w hucie stali. System pomiarowy wykorzystany do przeprowadzenia pomiarów jest oparty na systemie czasu rzeczywistego z układem FPGA, który pozwala na wykonanie pomiarów sygnałów analogowych. Trzy fazy napięcia i prądu zostały zmierzone w trzech wybranych punktach sieci zasilającej. Analiza częstotliwości ujawniła ciekawe zjawisko, w którym po wyłączeniu pieca łukowego częstotliwości napięcia i prądu w wewnętrznej części huty zmniejszyła się zamiast zwiększyć, jak można by się spodziewać. To nieoczekiwane zjawisko zostało zarejestrowane z pomocą PMU i potwierdzone przez analizę MatrixPencil. Przeprowadzone pomiary potwierdziły zasadność monitorowania częstotliwości napięcia zasilania pieców łukowych za pomocą analizy fazora.
EN
This paper presents the results of measurement experiment conducted in the operating steel plant. The measurement system was built with real time system with FPGA module, capable of measuring analog signals. Three phase voltages and currents were acquired in three selected points of supplying power network. Frequency analysis of measured signals revealed an interesting phenomenon, as it happened that after switching off the electric arc furnace, the frequency of the supplying voltage and current increased slightly instead of decreasing, as we would normally expect. This abnormal frequency behavior was identified by phasor analysis and also confirmed by DTFT (Discrete Time Fourier Transform) analysis, and MatrixPencil analysis. Performed measurements proved phasor analysis to be a useful application for electric arc furnace frequency monitoring.
PL
W pracy przedstawione zostało porównanie metod oceny indywidualnej emisji harmonicznych i wahań napięcia, na podstawie zagregowanych 10 minutowych wartości. Zaprezentowane przykłady wykorzystania opisanych metod bazują na pomiarach wykonanych w sieci dystrybucyjnej. Otrzymane wyniki potwierdzają zasadność wykorzystania danych 10-minutowych do oceny emisji analizowanych zaburzeń.
EN
The assessment of individual emission of electromagnetic disturbances in distribution networks is a very demanding task. The paper presents a comparison of methods for assessing individual harmonic emissions and voltage fluctuations, based on aggregated 10-minute values. IEC technical reports suggest that measurements of the aggregated 10-minute RMS current and voltage, used to assess individual harmonic emissions, should be performed for a sufficiently long time - a minimum of a week. The work used real measurements made in the distribution network. The obtained results confirm the legitimacy of using 10-minute data to assess the emissions of the analyzed disturbances.
PL
W ostatnim czasie operatorzy elektroenergetycznych systemów dystrybucyjnych w Polsce zainstalowali w swoich sieciach kilkadziesiąt tysięcy bilansujących liczników energii elektrycznej wyposażonych, zgodnie z wymaganiami Urzędu Regulacji Energetyki, w funkcje pomiaru wskaźników jakości dostawy energii elektrycznej. Liczniki te, z racji swoich nowych funkcji pomiarowych oferują nowe możliwości oceny funkcjonowania oraz diagnostyki sieci dystrybucyjnych. Są też źródłem znaczącego wolumenu danych pomiarowych. Artykuł prezentuje możliwości wykorzystania zagregowanych wartości 10-minutowych pomiaru jakości energii elektrycznej, pochodzących z rozproszonych przyrządów pomiarowych (liczników i analizatorów) energii elektrycznej, w celu lokalizacji dominujących źródeł zaburzeń w elektroenergetycznej sieci dystrybucyjnej.
EN
Recently, electricity distribution system operators in Poland have installed tens of thousands of balancing electricity meters, in accordance with the requirements of the Energy Regulatory Office, with the function of measuring the quality of electricity supply indicators. These meters, due to their new power quality measuring functions and significant volume, offer new possibilities in the assessment of functioning and diagnostics of power distribution systems. The article presents the possibility of using aggregated 10-minute power quality measurement data from electricity from dispersed electricity meters to locate dominant sources of disturbances in the power distribution network.
PL
W artykule zaprezentowano możliwości wykorzystania oprogramowania OpenDSS do komputerowej symulacji pracy sieci elektroenergetycznych w estymacji wartości skutecznej napięcia w nieopomiarowanych punktach sieci, jako wsparcie dla operatorów systemów dystrybucyjnych w monitorowaniu i diagnostyce pracy ich sieci. W artykule przedstawiono porównanie wyników pomiarów oraz symulacji pracy wybranego obszaru systemu dystrybucyjnego na poziomie średniego napięcia.
EN
The article contains a comparison of real measurements and simulation results of a distribution system at medium voltage with a resolution of 10-minutes. The cooperation of the measuring system and the simulation environment allowed to obtain a synergy effect by simplifying the model and at the same time increasing the accuracy of estimation. It was proposed to use a simulation environment to estimate the impact of renewable energy power plants on the distribution network.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.