Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
2
Content available remote Wind tunnel studies of cooling tower surface in terms of aerodynamic interference
EN
The cooling tower can be classified as a special structure, both in terms of reliability and size. The collapse of such a large tower, located closely to other buildings, may result in very serious consequences. It seems that special attention should be paid during design process of this kind of structures. Despite the increase in cost, the additional analysis and studies are indicated and also may raise reliability. The article presents the influence of wind action on the cooling tower. It consists of the studies on the issue of aerodynamic interference performed in the wind tunnel. The attention was particularly focused on the influence of the wind pressure on the shell of cooling tower, and on variability of these pressures on the surrounding objects. Making an adequate scale model, configuration of measuring equipment and an execution of wind tunnel tests will be described in this paper. The research was concentrated on measuring the pressure coefficients on the cooling tower surface in single situation and interference situations.
PL
Chłodnię kominową można zakwalifikować do grupy konstrukcji specjalnych zarówno pod względem niezawodności jak i rozmiaru. Zniszczenie tak wielkiego obiektu zlokalizowanego w sąsiedztwie budynków elektrowni może skutkować poważnymi konsekwencjami. Projektowanie wymaga szczególnej uwagi. Pomimo większych kosztów, dodatkowe badania i analiza są zalecone ze względu na niezawodność. Artykuł zawiera informacje o badaniach przeprowadzonych w tunelu wiatrowym nad zagadnieniem działania wiatru na chłodnię kominową oraz zjawiska interferencji aerodynamicznej. Szczególną uwagę zwrócono na wpływ zmiennego ciśnienia wiatru, na powierzchnię chłodni kominowej. Poniżej opisano proces wykonania modelu w odpowiedniej skali, konfigurację aparatury pomiarowej i wykonanie badań w tunelu wiatrowym. Badania były skupione na pomiarze współczynników ciśnienia wiatru na powierzchni chłodni kominowej w sytuacji z otoczeniem i bez niego.
EN
Before the widespread use of computers, the only way to design a structure with complex shape was to build a prototype model and perform the necessary tests. Nowadays, designers are able to create an accurate and complex engineering design by effective mathematical models. The paper describes the numerical analysis of cooling tower carried out by a finite element method. The FEM analysis was performed with Lusas software. The cooling tower represents the real structure located in Kozienice, Poland. During the calculations, different load cases based on wind tunnel tests were taken into account. The evaluation of the influence of different wind directions and configuration of obstacles on internal forces and displacements were analyzed. Proper dimensions, material proprieties and method factors were applied to the model. In the further part, the dynamic evaluation was presented. The Eigen modes with corresponding values and shapes were created and described. Estimation of impact of dynamic wind action on the object will be also released. Time history of amplitude and displacements was attached. As a result of the dynamic studies, the dynamic evaluating indicator was calculated.
PL
Przed rozpowszechnieniem komputerów, jedyną metodą projektowania obiektów o skomplikowanym kształcie, było zbudowanie modelu w celu przeprowadzenia niezbędnych badań. Obecnie, projektanci mogą tworzyć dokładne i złożone projekty poprzez dokładny model matematyczny. Referat opisuje analizę numeryczną chłodni kominowej metodą elementów skończonych przeprowadzoną w programie LUSAS. Chłodnia kominowa jest odzwierciedleniem obiektu zlokalizowanego w Kozienicach. Podczas obliczeń, wzięto pod uwagę wiele przypadków obciążenia wiatrem bazując na wynikach badań przeprowadzonych w tunelu wiatrowym. Zbadano ocenę wpływu różnych kierunków wiatru i lokalizacji sąsiadujących obiektów na siły przekrojowe i przemieszczenia. Odpowiednie wymiary, właściwości materiałowe i współczynniki zostały zastosowane. W następnej części przedstawiono oszacowanie efektu dynamicznego. Zaprezentowano wartości własne i odpowiadające im postaci własne. Przeprowadzono analizę czasową amplitudy i przemieszczeń. Jako podsumowanie badań dynamicznych oszacowano wskaźnik dynamiczny.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.