Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents the model study results of the modes and indicators of the power supply scheme of a small-capacity electric arc furnace with a non-valve “constant current – constant voltage” converter, aimed at further development, implementation and industrial testing of a pilot charter. The obtained data showed that such converter usage makes it possible to significantly reduce voltage fluctuations, voltage imbalance and the level of higher harmonics in the power system grid. At the same time, there are reduced the amount of reactive power consumption, ensured the smooth adjustment of the arc power, and increased the efficiency of the furnace.
PL
W tym artykule przedstawiono wyniki modelowych badań reżimów i indykatorów schematu zasilania elektrycznego pieca łukowego małej mocy z bezzaworowym przetwornikiem “stały prąd – stałe napięcie”, mających na celu dalszy opracowanie, wdrożenie i przemysłowe testowanie ustawy pilotowej. Uzyskane wyniki wykazały, że zastosowanie takiego przetwornika daje możliwość znacznego ograniczenia wahań napięcia, zmniejszenia asymetrii napięć oraz poziomu wyższych harmonicznych w sieci elektroenergetycznej. Jednocześnie zmniejsza się pobór mocy biernej, zapewniona jest płynna regulacja mocy łuku oraz zwiększa się wydajność pieca.
EN
The development of a mathematical model of a three-phase ultrahigh voltage transmission line with two overhead ground wires is presented in the paper. The mathematical model is based on differential equations of state of a long line with partial derivatives in the matrix-vector form. The boundary conditions of the second kind (Neumann's conditions) are used, which enables obtaining functions of unknown coordinates of the overhead ground wires mode at the beginning and at the end of the voltage transmission line to solve the transmission line equation. Some results of computer simulations of transients during switching on and a single-phase short circuit of the line are presented in the form of corresponding graphic functions of its mode coordinates.
PL
W artykule przedstawiono model matematyczny trójfazowej linii elektroenergetycznej ultra wysokiego napięcia z dwoma przewodami odgromowymi. Model matematyczny wykorzystuje równania różniczkowe o pochodnych cząstkowych elektromagnetycznej długiej linii w postaci macierzowo-wektorowej. Jako warunki brzegowe wykorzystano warunki drugiego rodzaju (warunki Neumanna), co z kolei pozwoliło obliczyć przebiegi napięcia i prądu na początku i na końcu linii elektroenergetycznej. Wyniki symulacji komputerowej stanów nieustalonych podczas załączania linii oraz zwarcia jednofazowego w jej końcu przedstawiono w postaci rysunków.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.