Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Within the confines of described work the structure of housing for surge arresters without gaps was carried out. This housing protects varistor stack against atmospheric agents (UV, moisture) and transfer the heat accumulated in varistor stack as a result of overvoltage. The materials for housing were selected and the optimal shape of external housing was carried out taking under consideration economic, thermal and insulating requirements. The goal of the work was successfully achieved and designed housing fulfils all requirements announced in the introduction of described work.
EN
This study includes hydrologic characteristics of the Potok Toszecki basin area and the results of chemical analysis of water quality of the Potok Toszecki. These investigations were carried out in following periods: from March 1993 till May 1994 and from January 1997 till June 1998. The results of investigations on the chemical parameters of water quality were compared with analysis, carried out in 1976. Under the results of this investigations water quality of the Potok Toszecki - a watercourse, which flows to the Plawniowice Reservoir - was defined and essential factors, connected with character of the basin area have been shown. Classification of several parameters was achieved under the official decree of the ministry of environmental protection from November 5th 1991. On the basis of this classification it was found, that the main risk for the Plawniowice Reservoir are biogenic substances and suspension, inflowing to the Reservoir together with the water of the Potok Toszecki. Improvement of the existing situation will be possible only if firm waste-water managements action will be taken.
PL
Przedstawiono wyniki pierwszych od czasu oddania Kanału Gliwickiego do eksploatacji w 1939 r. badań hydrodynamicznych. Główną przyczyna złej jakości wody jest stan rzeki Kłodnicy zasilającej kanał. W przypadku stężeń jonów chlorkowych (Cl), siarczanowych (SO(4)), sodowych (Na), potasowych (K), przewodnictwa właściwego, stężenia substancji rozpuszczonych jest pozaklasowej jakości. W przypadku BZT5 (BOD) i ChZT (COD) jakość wody zmienia się z pozaklasowej do II klasy czystości. Wartości odczynu wody oraz stężenia tlenu odpowiadają I klasie czystości. Mimo dopływu do kanału wód o znacznie mniejszym zasoleniu, jakość wody wzdłuż kanału uległa tylko nieznacznej poprawie. Spadek stężenia zanieczyszczeń wzdłuż osi kanału związany jest z ich rozproszeniem. W przypadku zmian jakości wody procesy samooczyszczania odgrywają role drugoplanowa.
EN
The results of the first (since 1939) hydrochemical investigations of Gliwice Channel have been presented. The polluted Klodnica River affects bad water quality of the canal. For example the concentrations of chlorides (Cl), sulfates (SO(4)), sodium (Na), potassium (K), conductivity and dissolved substances quality of water is out of standards. In the case of BOD and COD the water quality is changed from out of classes to II class. pH and oxygen concentration are in I class. Although no salinity waters flow into the canal, the water quality get improved slightly only. The decrease of pollutants concentration is related to theirs dispersion. In the case of water quality the self-purification processes are of secondary importance.
PL
W artykule przedstawiono nową metodę pomiaru współczynnika przewodności cieplnej dotyczącą dielektryków stałych. W metodzie tej wykorzystuje się efekt przekazywania ciepła na drodze przewodnictwa ze źródła do próbki traktowanej jako ciało półnieskończone. Analiza zmiany temperatury źródła umożliwia wyznaczenie współczynnika przewodności cieplnej badanej próbki. Metoda umożliwia szybkie wykonanie pomiaru bez konieczności obróbki materiału badanego.
EN
This paper presents the design of a novel and simple set-up for measuring the thermal conductivity of solid dielectrics. The technique is based on recording the transient temperature decrease of a copper rod clamped to the specimen surface. The advantage of the method is that the surface of the specimen is not to be specially prepared.
PL
W artykule przedstawiono dwie grupy metod pomiarowych własności termokinetycznych materiałów: tradycyjną metodę pomiaru współczynnika przewodności cieplnej wraz z jej adaptacja do aktualnych wymogów techniki pomiarowej oraz kilka współczesnych metod pomiarowych, dotyczących nieustalonych warunków transportu ciepła i praktyczną ich realizację.
EN
The article presents two groups of methods the thermokinetics parameters of materials measuring: the traditional method of measurement the coefficient l, and several chosen transients methods and their practically realization.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.