The article presents an analysis of the results obtained from the testing of simply supported reinforced concrete beams subjected to four-point bending. The beams, with two levels of steel reinforcement (ρs1=1.26%, ρs2=0.71%), and dimensions of 0.12x0.30x3.30m, were subjected to loading involving a sudden increase in force with multiple unloading cycles to zero. The study included comparative analysis of deflection results obtained from experimental tests (calculated based on the curvature of the element and readings from measurement devices) with deflection values obtained through calculations based on two selected standards. Real values of ultimate bending moments were also compared with theoretical values. Additionally, compressive strength tests were conducted on eight cubic concrete specimens with a side length of b=150mm, obtained for each concrete batch. They constitute accompanying studies. Using standard procedures, strength and statistical parameters were estimated and evaluated, taking into account the assessment of the quality of the concrete production used to make the reinforced concrete beams. Ensuring compliance with the process of producing full-sized reinforced concrete beams with existing standard procedures, as well as attention to the quality of concrete production, contributed to achieving satisfactory results in the experimental tests. Knowledge about the impact of loading on mechanical properties enables effective management of factors shaping quality to obtain a construction material with optimal parameters.
W artykule przedstawiono propozycję prostego podejścia do szacowania nośności belek żelbetowych wzmocnionych taśmami CFRP, które zostało oparte na wynikach badań eksperymentalnych 10 belek żelbetowych. Badania 2 belek referencyjnych i 8 wzmocnionych taśmami CFRP wklejonymi w betonową otulinę (metoda NSMR) wykonano, symulując rzeczywiste warunki wykonywania wzmocnień. Belki zostały wzmocnione pod obciążeniem w pozycji sufitowej. Wyniki nośności belek uzyskane z badań porównano z wynikami obliczeń na podstawie zaproponowanego podejścia, przyjmując wytrzymałość betonu i stali z badań próbek towarzyszących, a także z normy dla zastosowanej klasy betonu i stali. Porównanie wskazuje na bezpieczne szacowanie nośności.
EN
The article presents a proposal for a simple method of estimating the load-bearing capacity of RC beams strengthened with CFRP strips, based on the results of experimental tests of 10 beams. Tests of two reference beams and eight beams strengthened with CFRP strips glued into the concrete cover (NSMR method) were carried out by simulating the real conditions of strengthening. The beams were strengthened under sustained loading were the strip was applied in the bottom side. The beam load-bearing capacity results obtained from the tests were compared with the calculation results based on the proposed simple method. To estimate the load-bearing capacity, the strength of concrete and steel from the accompanying tests and those provided in the standard regulations was adopted. The comparison indicates a safe estimation of the load capacity.
Przedmiotem referatu jest podłoga przemysłowa eksploatowana w warunkach przetwórstwa spożywczego. Analizie jest poddany przykład istniejącej podłogi, na którą jest cyklicznie zrzucany odciek o pH od 5,5 do 6,5. Ze względów higienicznych podłoga jest zmywana płynami z detergentami, jak również poddawana działaniu pary. Ze względu na negatywny wynik oceny zarówno stanu technicznego, jak też istniejącego rozwiązania, za racjonalne uznano wyłącznie zaprojektowanie i wykonanie podłogi zupełnie od nowa. Autorzy analizują projekt przyjętych rozwiązań związanych z podbudową, izolacją, warstwą ślizgową, płytą betonową, posadzką, powierzchniowym i liniowym odprowadzaniem odcieków i płynów. Całość uwzględnia wyniesione ponad poziom podłogi fundamenty pod różne urządzenia linii produkcyjnej z transportem rurociągami. W związku z wysokim stopniem odpowiedzialności za profesjonalną przebudowę w rozwiązaniach podano wprost nazwy handlowe zastosowanych materiałów budowlanych.
EN
The subject of the paper is industrial floor operated in food processing conditions. The analysis covers an example of an existing floor, onto which a segment with a pH of 5.5 to 6.6 is cyclically dropped. For hygienic reasons, the floor is washed with detergents and steam. Due to the negative result of the assessment of both the technical condition and the existing solution, it was only reasonable to design and build the floor from scratch. The authors analyze the design of the adopted solutions related to the foundation, insulation, sliding layer, concrete slab, floor, surface and linear drainage of leachate and fluids. And the whole takes into account the foundations above the floor level for various equipment of the production line with pipeline transport. Due to the high degree of responsibility for professional conversion into solutions, the trade names of the building materials used were explicitly given.
This paper presents the analysis of the results of research on concrete compressive strength on cubic samples, in the early stage of its curing (after 7, 14, and 28 days). The analysis considers the variable water-cement ratio. Statistical and strength parameters were assessed, estimating the quality of the obtained concrete at the same time. Verification of the expected C25/30 concrete grade was carried out from the recipe provided by the prefabrication plant. Then, the grammage of individual components was adjusted to obtain the grade of concrete assumed by the authors. The article estimates the concrete grade based on strength parameters in three stages of concrete curing. The concrete was then compared with the concrete class calculated based on standard procedures (EC2 procedures), which could be reached after 28 days. The paper also provides an overview of the most used methods of testing concrete compressive strength.
PL
W artykule przedstawiono analizę wyników uzyskanych z badania wytrzymałości betonu na ściskanie na próbkach sześciennych we wczesnej fazie jego dojrzewania (po 7, 14 i 28 dniach), z uwzględnieniem zmieniającej się wartości stosunku wodno-cementowego. Dokonano oceny parametrów zarówno statystycznych jak i wytrzymałościowych, szacując przy tym jakość produkcji otrzymanego betonu. Przeprowadzono weryfikację oczekiwanej klasy betonu C25/30, z udostępnionej przez zakład prefabrykacji receptury, a następnie zmieniono gramaturę poszczególnych jej składników w celu uzyskania założonej przez autorów klasy betonu równej C20/25. W artykule oszacowano klasę betonu na podstawie parametrów wytrzymałościowych w trzech stadiach czasowych i porównano ją z wyznaczoną według przepisów normowych wartością, która mogłaby zostać osiągnięta po 28 dniach. Otrzymane wyniki badań porównano z wyznaczonymi zgodnie z normą Eurokod 2 wartościami wytrzymałości, które mogłaby zostać osiągnięte po 28 dniach i oszacowaną na tej podstawie klasą betonu. W pracy dodatkowo przedstawiono przegląd najczęściej stosowanych metod badań wytrzymałości betonu na ściskanie.