Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Energy efficient buildings ‒ lower structure
EN
Part of the package of low-energy and passive houses is the basement and foundation too. A correct proposal of construction detail of buildings that lying on the soil is one of the steps that contribute to reducing energy requirements for heating and operation of building. At the same time increase the quality of the indoor environment as well as performance at work. In the construction of the lower structure, the most delicate point is the contact of walls, foundations and floor structure with the soil and subsoil, this frequently leads to inconsistent solutions of the design detail, resulting in the formation of thermal bridges with subsequent condensation
PL
Poprawne rozwiązanie szczegółów budynku będących w kontakcie z ziemią jest jednym z istotnych kroków, które przyczyniają się do zmniejszenia zapotrzebowania na energię do ogrzewania i eksploatacji budynku. Jednocześnie poprawie ulega jakość środowiska wewnętrznego i wydajności pracy. W dolnej części budynku najbardziej wrażliwe są miejsca styku ścian, fundamentów oraz podłogi z gruntem i podłożem, są one często niewłaściwie rozwiązywane, powodując powstawanie mostków termicznych i dalej kondensację pary wodnej.
2
Content available remote Energy efficiency of ventilation system in apartment buildings
EN
The article shows impact of the location of apartments on the heat requirement of each type of apartment as well as the possibility of different savings of heat by using ventilation equipments including recuperative devices.
PL
Artykuł przedstawia wpływ lokalizacji mieszkania na wymagania cieplne poszczególnych lokali jak również możliwości oszczędzania energii przy użyciu systemu wentylacji z rekuperacją.
3
Content available remote Implementation of ventilated air cavities and problems with thermal bridges
EN
Historical buildings generally have no, or only have a passive protection of structures against the ingress of moisture in contact with soil. Materials embedded in structures of these buildings are often saturated with moisture. When reconstructing, we must apply a different methodology than when reconstructing the newer buildings. Differentiated treatment is affected by traditional construction technologies and also by the mechanical and physical properties of building materials. As regards listed historic monuments, special „barrier” is constituted by the monument protection office, or rather the opinion of the representative of the monument protection office. Its priority is the selection of those remedial treatments, which, if not stop the spread of moisture, at least eliminate it. In all of that there is the emphasis on the methodology of preservation of historical monuments and constructional possibilities of historic buildings. With respect to the abovementioned requirements, the acting humidity can be effectively removed, using ventilated air cavities. These are commonly used in connection with remedial treatments of damp masonry, especially in historic buildings.
4
Content available remote Shape of buildings and energy consumption
EN
This paper provides analysis of buildings shape (ground plan and vertical division) and their impact of shape factor – FT of buildings. For some shape is provide a parametric analysis obtained from a comprehensive whole building energy simulation. Parametric analysis regards orientation of buildings and ratio %glazing to the wall.
PL
W niniejszym artykule przedstawiono analizę kształtu budynków (rzut poziomy i podział pionowy) oraz ich wpływ na czynnik kształtu FT. Dla niektórych kształtów przygotowano analizę parametryczną opartą na pełnej symulacji energetycznej. Analiza parametryczna dotyczy orientacji budynków oraz procentowej proporcji przeszklenia do ściany.
EN
Designing a building requires the interplay of architecture and design parameters to create an artificial material environment. Each architectural and engineering design has a direct impact on the indoor climate environment and a key determinant of operational performance of buildings throughout the life of the building. One important component of the process of reducing the operating energy performance of buildings within a designated period of their exploitation as packaging design of buildings and their physical and technical characteristics, which are intended design concept and building material solutions.
PL
Projektowanie budynku wymaga wzajemnego oddziaływania między parametrami architektonicznymi a projektowymi w celu stworzenia sztucznego środowiska materialnego. Każdy projekt architektoniczny i inżynierski wywiera bezpośredni wpływ na środowisko klimatu wnętrz i stanowi kluczowy wyznacznik użytkowej wydajności budynków w ich pełnym cyklu życiowym. Jednym z istotnych elementów procesu ograniczania użytkowej wydajności energetycznej budynków w wyznaczonym okresie eksploatacyjnym jest pakietowy projekt budynków i ich charakterystyki fizyczno-technicznej jako zamierzona koncepcja projektowa z rozwiązaniami w zakresie materiałów budowlanych.
6
Content available remote Energy saving - as a result of suitable design of building s bottom constructions
EN
External constructions of buildings provide their protection of external influences. These constructions ought to create an optimal comfort of interior environment in winter as well as in summer. It has been shown in practice that the largest number of breakdown is in external constructions. The external constructions of walls, roofs and floors too, present a big area of problems in design of new and reconstructed buildings respectively. Heat losses of buildings trough external constructions - roof, external wall, floor on the ground are not negligible. It is therefore important to pay more attention to these constructions.
PL
Konstrukcja zewnętrzna budynku zapewnia jego ochronę przed wpływami zewnętrznymi. Konstrukcja ta powinna stwarzać optymalny komfort środowiska wewnętrznego zarówno w zimie, jak i w lecie. W praktyce okazuje się, że największa ilość awarii następuje w konstrukcjach zewnętrznych. Zewnętrzne konstrukcje ścian, dachów i podłóg stwarzają problemy zarówno przy projektowaniu nowych budynków, jak i przy rekonstrukcji istniejących obiektów. Straty ciepła przez konstrukcje zewnętrzne - dach, ścianę zewnętrzną, podłogę na gruncie nie są bez znaczenia. Dlatego tak ważne jest zwrócenie uwagi na te konstrukcje.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.