Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The results of municipal wastewater treatment by chemical coagulation with PIX and electrocoagulation in a recirculation system with aluminum electrodes were discussed and interpreted. Those processes were analyzed as: a) preliminary processing before biological treatment, or b) the only treatment procedure. The results of chemical coagulation and electrocoagulation indicate that both methods guarantee the required level of phosphorus and suspended solids removal from wastewater. Despite the above, the COD of treated wastewater decreased to only 200 mg×dm–3 which exceeds the norm for effluents discharged from treatment plants (125 mg×dm–3). Our results indicate that municipal wastewater treatment cannot rely solely on chemical coagulation and/or electrocoagulation. In successive parts of the study, wastewater was treated with significantly smaller doses of a ferric coagulant (PIX) and an aluminum electrocoagulant (Al electrodes). The above treatments lowered the phosphorus load of wastewater to a level ensuring its nearly complete removal in successive stages of biological treatment. The practical application of the resulting database was evaluated in view of the existing regulations as well as more stringent requirements which could be introduced in the future, in particular with regard to total phosphorus loads.
PL
W pracy opisano i zinterpretowano rezultaty procesów oczyszczania ścieków miejskich koagulowanych chemicznie PIX-em oraz elektrokoagulowanych recyrkulacyjnie na elektrodach glinowych. Procesy te potraktowano jako: a) etap wstępny, przed biologicznym oczyszczaniem badanych ścieków oraz b) jedyne i ostateczne oczyszczanie ścieków. Wyniki badań procesu koagulacji chemicznej oraz elektrokoagulacji badanych ścieków pokazały, że metody te zapewniają wymagany poziom usunięcia zawiesin i fosforu z oczyszczanych ścieków. Jednakże ChZT tak oczyszczonych ścieków obniżało się tylko do ok. 200 mg·dm–3 przy wymaganym poziomie 125 mg·dm–3 w odpływie z oczyszczalni. Fakt ten nie pozwala więc traktować koagulacji chemicznej lub/i elektrokoagulacji jako jedynego i ostatecznego etapu oczyszczania badanych ścieków miejskich. Stąd w dalszej części badań ścieki traktowano znacznie mniejszymi dawkami koagulantu żelazowego (PIX) i elektrokoagulantu glinowego (elektrody Al). Prowadziło to do częściowego usunięcia fosforu, zapewniając takie obniżenie poziomu P, aby kolejny etap biologicznego oczyszczania mógł zapewnić stężenie tego biogenu w odpływie bliskie zeru. Dokonano oceny wartości aplikacyjnej uzyskanej bazy danych w świetle aktualnych norm i uwarunkowań, jak również w szerszej perspektywie zaostrzenia wymagań w zakresie stopnia oczyszczenia ścieków, szczególnie w zakresie usuwania fosforu.
EN
Wastewater coagulation and electrocoagulation were investigated as sorption processes involving colloidal sorbents such as (Al(OH)3)n, (Fe(OH)3)m and (Fe(OH)2)p. An attempt was made to fit experimental data to two popular sorption models. Based on a statistical and mathematical analysis of the obtained results, the Langmuir model of chemical adsorption was regarded more probable than the Freundlich model. The highest maximum adsorption of phosphorus in the analyzed wastewater was achieved with the use of PIX, and the lowest adsorption maxima were reported for an iron electrocoagulant. PAC was most effective in reducing COD of wastewater. PAC and PIX delivered higher adsorption maxima for compounds responsible for COD than aluminum and iron electrocoagulants.
3
Content available remote Destabilization of model wastewater in the chemical coagulation process
EN
This paper discusses the results of laboratory analyses of the coagulation and flocculation of model wastewater. The investigated wastewater was susceptible to treatment by chemical coagulation. The effectiveness of two commercial coagulants, PAC produced at the DEMPOL-ECO Chemical Plant and PIX manufactured by KEMIPOL, was compared. A mathematical model relying on a second-degree polynomial was used to describe and analyze experimental data. In each case, the parabola minimum point was a precisely determined coagulant dose, regarded as the optimal dose. The application of a coagulant dose higher than the optimal dose reduced the effectiveness of wastewater treatment by coagulation. A detailed analysis of turbidity, suspended solids, total phosphorus and pollutant removal measured by the COD test revealed that PAC was a more effective and a more efficient coagulant than PIX. The risk of coagulant overdosing was greater with the use of PAC than PIX.
PL
W niniejszej pracy przedstawiono, opisano i zinterpretowano wyniki badań laboratoryjnych procesu koagulacji-flokulacji ścieków modelowych. Zastosowane ścieki modelowe okazały się podatne na oczyszczanie metodą koagulacji chemicznej. Zastosowano i porównano dwa komercyjne koagulanty: PAC - wyprodukowany w zakładach chemicznych DEMPOL-ECO oraz PIX - wyprodukowany przez firmę KEMIPOL. Do przedstawienia i analizy uzyskanej bazy danych doświadczalnych z powodzeniem zastosowano model matematyczny w postaci wielomianu drugiego stopnia. Minimum takiej paraboli każdorazowo stanowiła dawka koagulantu precyzyjnie obliczana i traktowana jako dawka optymalna. Zastosowanie wyższej, aniżeli optymalna, dawki koagulantu prowadziło każdorazowo do obniżenia stopnia oczyszczenia koagulowanych ścieków. Szczegółowa analiza wyników usuwania mętności, zawiesin, fosforu ogólnego i zanieczyszczeń określanych w skali ChZT pokazała, że PAC skuteczniej i wydajniej, aniżeli PIX, koagulował badane ścieki modelowe. Jednakże zagrożenie tzw. przedawkowania koagulantu okazało się większe ze strony PAC-u aniżeli przy wykorzystaniu PIX-u.
PL
W niniejszej pracy przedstawiono, opisano i zinterpretowano wyniki badań laboratoryjnych procesu koagulacji-flokulacji ścieków modelowych. Zastosowane ścieki modelowe okazały się podatne na oczyszczanie metodą koagulacji chemicznej. Zastosowano i porównano dwa komercyjne koagulanty: PAC - wyprodukowany w zakładach chemicznych DEMPOL-ECO oraz PIX - wyprodukowany przez firmę KEMIPOL. Do przedstawienia i analizy uzyskanej bazy danych doświadczalnych z powodzeniem zastosowano model matematyczny w postaci wielomianu drugiego stopnia. Minimum takiej paraboli każdorazowo stanowiła dawka koagulantu precyzyjnie obliczana i traktowana jako dawka optymalna. Zastosowanie wyższej, aniżeli optymalna, dawki koagulantu prowadziło każdorazowo do obniżenia stopnia oczyszczenia koagulowanych ścieków. Szczegółowa analiza wyników usuwania mętności, zawiesin, fosforu ogólnego i zanieczyszczeń określanych w skali ChZT pokazała, że PAC skuteczniej i wydajniej, aniżeli PIX, koagulował badane ścieki modelowe.
EN
This paper discusses the results of laboratory analyses of the coagulation and flocculation of model wastewater. The investigated wastewater was susceptible to treatment by chemical coagulation. The effectiveness of two commercial coagulants, PAC produced at the DEMPOL-ECO Chemical Plant and PIX manufactured by KEMIPOL, was compared. A mathematical model relying on a second-degree polynomial was used to describe and analyze experimental data. In each case, the parabola minimum point was a precisely determined coagulant dose, regarded as the optimal dose. The application of a coagulant dose higher than the optimal dose reduced the effectiveness of wastewater treatment by coagulation. A detailed analysis of turbidity, suspended solids, total phosphorus and pollutant removal measured by the COD test revealed that PAC was a more effective and a more efficient coagulant than PIX.
5
EN
This paper presents the results of electrocoagulation of model wastewater using iron electrodes under laboratory conditions. The investigated wastewater was susceptible to electrolytic treatment, and the model system supported the performance of analyses in seven replications, generating a database for reliable statistical and mathematical processing. Wastewater was treated by chronopotentiometric electrocoagulation in a static system at constant current intensity I = 0.3 A. Changes in supply voltage for I = const were registered over time. Changes in pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the iron electrocoagulant was proposed by relying on the third degree polynomial function rather than the parabolic equation. The proposed method, justified theoretically and demonstrated practically, enabled precise determination of the electrocoagulant dose. An increase in the electrocoagulant dose increased the share of sweep electrocoagulation in the wastewater treatment process.
PL
W pracy przedstawiono wyniki badań laboratoryjnych procesu elektrokoagulacji ścieków modelowych na elektrodach żelaznych. Użyte ścieki okazały się podatne na oczyszczanie elektrolityczne i tym samym, jako układ modelowy, umożliwiły prowadzenie badań aż w 7 powtórzeniach, co z kolei zapewniło bazę danych nadającą się do wiarygodnej obróbki statystyczno-matematycznej. Oczyszczanie ścieków prowadzono w statycznych warunkach chronopotencjometrycznych, tj. przy stałym prądzie I = 0,3 A. Każdorazowo rejestrowano zmiany napięcia zasilania w czasie zapewniające I = const. Oznaczano zmiany pH, zawiesin i mętności, ChZT oraz fosforu ogólnego w oczyszczanych ściekach. W odróżnieniu od metody wyznaczania dawki koagulantu z równania odpowiedniej paraboli, dla badanego procesu elektrokoagulacji zaproponowano oryginalną, nową metodę obliczania dawki optymalnej elektrokoagulantu żelazowego z równania wielomianu III stopnia. Metoda ta, uzasadniona teoretycznie i praktycznie, umożliwiała każdorazowo bardzo precyzyjne określenie takiej dawki. Stwierdzono, że wzrost dawki elektrokoagulantu żelazowego w układzie prowadzi do zwiększenia udziału elektrokoagulacji „zamiatającej” w badanym procesie oczyszczania ścieków.
PL
Przedstawiono wyniki badań laboratoryjnych procesu elektrokoagulacji ścieków modelowych na elektrodach żelaznych. Użyte ścieki okazały się podatne na oczyszczanie elektrolityczne i tym samym, jako układ modelowy, umożliwiły prowadzenie badań aż w 7 powtórzeniach, co z kolei zapewniło bazę danych, nadającą się do wiarygodnej obróbki statystyczno-matematycznej. Oczyszczanie ścieków prowadzono w statycznych warunkach chronopotencjometrycznych, tj. przy stałym natężeniu prądu I = 0,3 A. Każdorazowo rejestrowano zmiany napięcia zasilania w czasie, zapewniające I = const. Oznaczano zmiany pH, zawiesin i mętności, ChZT oraz fosforu ogólnego w oczyszczanych ściekach. W odróżnieniu od metody wyznaczania dawki koagulantu z równania odpowiedniej paraboli dla badanego procesu elektrokoagulacji zaproponowano oryginalną, nową metodę obliczania dawki optymalnej elektrokoagulantu żelazowego z równania wielomianu III stopnia. Metoda ta, uzasadniona teoretycznie i praktycznie, umożliwiała każdorazowo bardzo precyzyjne określenie takiej dawki. Stwierdzono, że wzrost dawki elektrokoagulantu żelazowego w układzie prowadzi do zwiększenia udziału elektrokoagulacji „zamiatającej” w badanym procesie oczyszczania ścieków.
EN
This paper presents the results of electrocoagulation of model wastewater using iron electrodes under laboratory conditions. The investigated wastewater was susceptible to electrolytic treatment, and the model system supported the performance of analyses in seven replications, generating a database for reliable statistical and mathematical processing. Wastewater was treated by chronopotentiometric electrocoagulation in a static system at constant current intensity I = 0.3 A. Changes in supply voltage for I=const were registered over time. Changes in pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the iron electrocoagulant was proposed by relying on the third degree polynomial function rather than the parabolic equation. The proposed method, justified theoretically and demonstrated practically, enabled precise determination of the electrocoagulant dose. An increase in the electrocoagulant dose increased the share of sweep electrocoagulation in the wastewater treatment process.
EN
Electrocoagulation makes an alternative method to chemical coagulation. This paper presents the results obtained during the electrocoagulation of the model wastewater using aluminum electrodes. The wastewater was treated by means of chronopotentiometric electrocoagulation process in a static system, at the constant current I = 0.3 A; therefore higher doses of electrocoagulant required longer electrocoagulation time. Changes in zeta potential, pH, turbidity, chemical oxygen demand (COD), suspended solids and total phosphorus concentrations in the treated wastewater were determined. A new method for determining the optimal dosage of the aluminum electrocoagulant was proposed through application of the third degree polynomial function rather than the parabolic equation. An increase in the electrocoagulant dose raised the share of sweep fl occulation in the studied treatment process, resulting in the effective removal over 90% of phosphorus compounds from the system.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.