Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 16

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The presented investigations were conducted on a modified impulse two-stage low-pressure model turbine with low-aspect ratio of airfoils. Real impulse turbine geometry has been used for both stages to investigate flow problems. A new supply system maintained very stable conditions at the inlet and flow-calming mesh-wiring and acoustic adaptation were built. These improvements allowed identification of different flow effects. A new measurement system was tested for investigations of influence of phenomena related, among others, to unsteady flow structures connected to vane indexing. It is of key importance for the turbine efficiency measurement.
PL
Przedstawione badania zostały przeprowadzone na zmodyfikowanym stanowisku badawczym niskociśnieniowej dwustopniowej turbiny akcyjnej o małej rozpiętości łopatek. Przy projektowaniu geometrii turbiny do badań zagadnień przepływowych oparto się na geometrii rzeczywistej turbiny. Nowy system zasilania zapewnił bardzo stabilne warunki na wlocie, dodatkowo wstawiono siatki uspokajające oraz adaptację akustyczną. Ulepszenia te zapewniły identyfikację różnych efektów przepływowych. Przetestowano nowy system pomiarowy na potrzeby badań wpływu zjawisk związanych, między innymi, ze strukturami niestacjonarnymi powiązanymi ze zmianą położenia kierownic. Jest to kluczowe zagadnienie z punktu widzenia pomiarów sprawności turbiny.
EN
The paper investigates relationships between chemical structure, surface active properties and antibacterial activity of 70 bis-quaternary imidazolium chlorides. Chemical structure and properties of imidazolium chlorides were described by 7 condition attributes and antimicrobial properties were mapped by a decision attribute. Dominance-based Rough Set Approach (DRSA) was applied to discover a priori unknown rules exhibiting monotonicity relationships in the data, which hold in some parts of the evaluation space. Strong decision rules discovered in this way may enable creating prognostic models of new compounds with favorable antimicrobial properties. Moreover, relevance of the attributes estimated from the discovered rules allows to distinguish which of the structure and surface active properties describe compounds that have the most preferable and the least preferable antimicrobial properties.
3
Content available remote Politechnika Łódzka w okresie transformacji 1990-1996
PL
Politechnika Łódzka, podobnie jak i wszystkie polskie uczelnie, przeszła bardzo poważne zmiany w okresie transformacji ustrojowej naszego kraju, co nie zostało dotychczas wyczerpująco opisane. W latach 1990-96, kiedy zmiany te najintensywniej były wprowadzane, byłem rektorem i wraz z prorektorami prof. Bolesławem Bolanowskim, prof. Januszem Turowskim, prof. Romanem Zarzyckim (w pierwszej kadencji) i z prof. Józefem Mayerem (w drugiej) wiele tych przeobrażeń inicjowaliśmy i wprowadzaliśmy. Wychodząc naprzeciw inicjatywie Rektorskiej Komisji Historycznej postanowiłem je opisać. Ograniczyłem się do lat 1990-1996 kiedy uczelnia doznała zasadniczych przeobrażeń. W poniższych rozważaniach opieram się na takich źródłach jak „Księga jubileuszowa PŁ", wydana w 1995 na 50-lecie uczelni, wydawnictwie „Życia Uczelni", protokołach z posiedzeń Senatu PŁ, corocznych sprawozdaniach rektora, przemówieniach rektora, wywiadach prasowych itp. Jednocześnie podpieram się własnymi notatkami, które systematyczne robiłem od grudnia 1990. Opisywanym działaniom w okresie 1990-96 towarzyszą moje osobiste wspomnienia i komentarze. Jeśli kogokolwiek one dotykają, to z góry przepraszam.
4
Content available remote Koncepcja hybrydowej siłowni geotermalnej w Uniejowie
PL
W artykule opisano trzy warianty siłowni hybrydowych, które zasilane są energią z geotermii oraz energią cieplną biomasy w postaci słomy. Moc produkowaną w układach hybrydowych porównano z mocą wytwarzaną przez układ referencyjny, tzn. taki, w którym część geotermalna jest całkowicie rozdzielona z obiegiem zasilanym biomasą. Pozwala to ocenić, jak duży wpływ na sprawność ma zastosowanie układu hybrydowego. Zakłada się, że biomasa będzie spalana w kotle parowym, a zatem ta część obiegu będzie pracowała na wysokich parametrach. Część geotermalna będzie natomiast oparta na czynniku niskowrzącym (ORC). W ostatnim rozdziale przeprowadzono rozważania odnośnie turbin, które mogłyby być zastosowane w obiegach.
EN
Three schemes of the hybrid power plants powered by geothermal energy and heat energy of biomass (in form of straw) were described in the paper. The power produced by the systems was compared to the power produced by the reference system in which the geothermal part and biomass cycle are fully separated. It allows to assessing the influence of utilization of the hybrid scheme on the power plant efficiency. It is assumed that the biomass is combusted in a steam boiler so that this part of the cycle works with high steam parameters. The geothermal part is based on a refrigerant (ORC cycle). In the last section brief considerations are presented in respect to the turbines that could be applied in the cycles.
6
Content available remote Vane bowing and clocking technique influence on two-stage turbine performance
EN
This paper describes the experimental investigations of the clocking effects on the turbine performance characteristics. The turbine was equipped with rake temperature and pressure probes and fast response miniature pressure sensors and surface-mounted hot film sensors. To understand better an interaction mechanism and show how some flow effects can be successfully employed in estimation and correlation of stage losses, quasi-three-dimensional simulations of the airfoil clocking have been performed. Time-averaged and unsteady data including performance of particular blade/vane rows are presented and used to minimize the stage loss production due to upstream flow conditions. The results show a turbine total efficiency variation from 0.1% to 0.5%. The experiments have shown that the clocking effect seems to be mainly related to the low momentum flow region, which should be introduced into a leading edge region of the downstream vane/blade row, where the fluid momentum will be already low. Primary loss production in the blade row will be a function of the geometry and inlet time mean flow conditions and the distribution along the circumferential direction.
EN
Detailed experimental investigations were conducted of flow structures in a model two-stage low-pressure turbine. The objective of this study was to gain more insight into phenomena affecting flow behaviour due to the indexing airfoils in multi-stage machines. To investigate the effect of the vane clocking on turbine efficiency an analysis of the experimental results throughout the flow field for different circumferential positions of the first stator was performed. Detailed flow pictures were measured for all measuring planes according to the radial and circumferential inter-row traversing. Aerodynamic measurements were compared to the turbine nominal speed and design clocking position of the two stators. Herein, some steady and unsteady flow measurement results, and the external characteristics for different circumferential positions of the stator vanes are described. The experimental investigations presented in this paper were carried out since mid-nineties [1] on a 2-stage turbine research facility TM-3 at the Institute of Turbomachinery of Technical University of Lodz.
8
Content available remote Efficiency Variations Due to the Vane Indexing in a Two-Stage Turbine
EN
The objective of this study was to gain more insight into phenomena affecting flow behaviour due to the indexing airfoil effects in multi-stage machines. To investigate the effect of the vane clocking on axial turbine efficiency and performance, an analysis of the experimental results of the steady and unsteady flow measurements throughout the flow field for different circumferential positions of the first stator has been performed. Aerodynamic measurements were compared to the turbine design speed and to the classical clocking position of the two stators [1].
PL
W artykule przedstawiono nowego rodzaju układ siłowni dwupaliwowej. Siłownię tworzą kocioł węglowy generujący parę wodną, czołowa przeciwprężna turbina parowa i nowego rodzaju turbinowy silnik parogazowy. Para wodna opuszczająca turbinę parową jest wtryskiwana zarówno do komory spalania turbinowego silnika parogazowego jak i wykorzystywana do chłodzenia łopatek w pierwszych stopniach turbiny. Obniżenie ciśnienia wylotowego z turbiny pozwala bardziej zbliżyć obieg do obiegu Carnota niż jest to możliwe w obiegu zwykłej turbiny gazowej. W artykule przedstawiono schemat cieplny układu wraz z wynikami szczegółowych obliczeń termodynamicznych obiegu jak i dokonano analizy wymiarowej proponowanego rozwiązania turbiny silnika parogazowego. Układ jest szczególnie interesujący dla krajów o dużych zasobach węgla, gdyż pozwala na uzyskanie sprawności porównywalnej ze sprawnością kombinowanej siłowni parowo-gazowej wykorzystując do zasilania nie tylko drogi gaz ziemny ale i łatwo dostępny węgiel.
PL
W artykule zajęto się nowego typu układem silnika ze spalaniem wewnętrznym składającego się z turbiny parogazowej z wtryskiem pary wodnej i obniżonym ciśnieniem wylotowym.
EN
A new kind of engine with internal combustion, which consists of a gas turbine with steam injection and lowered outlet pressure and a circulating fluidized bed boiler, is described in detail. The system description and results of the efficiency computations are presented. The proposed solution benefits and limits are presented as well.
11
Content available remote Rozwój potencjału geotermii: stacje geotermalne w eksploatacji i w budowie
PL
Pomimo znacznego potencjału energetycznego wód geotermalnych w Polsce, dopiero w ostatnim dziesięcioleciu rozpoczęła się ich techniczna eksploatacja. Do początku lat 90. wody termalne wykorzystywane były przede wszystkim w balneologii i rekreacji. Natomiast w latach 1993-2003 zbudowano i uruchomiono w Polsce sześć instalacji ciepłowniczych bazujących na energii gorących wód podziemnych, a budowa kolejnych obiektów jest planowana w najbliższej przyszłości. Niniejsza praca przedstawia stan istniejący oraz perspektywy wykorzystania energii wód geotermalnych i rozwoju instalacji geotermalnych w Polsce.
PL
Praca zawiera podstawowe rezultaty wraz z wnioskami końcowymi analizy ekonomicznej, przeprowadzonej w ramach wspólnego grantu Urzędu Miasta Łodzi i Politechniki Łódzkiej, a dotyczącej możliwych do zrealizowania wariantów geotermalnej stacji doświadczalnej na terenie Politechniki Łódzkiej oraz wskazanie najwłaściwszego rozwiązania układu. Realizacja stacji geotermalnej na terenie PŁ pozwoliłoby na zebranie doświadczeń umożliwiających budowę podobnych stacji zarówno w regionie łódzkim jak i w Polsce.
PL
W artykule przedstawiono koncepcję kilku różnych systemów dwupaliwowych spalających gaz ziemny węgiel brunatny w różnych proporcjach. W systemach tych kocił parowy z cyrkulacyjną warstwą fluidalną OFz-425 produkcji RAFAKO sprzężono z turbinami gazowymi, pracującymi wg obiegu prostego, z chłodzeniem międzysekcyjnym sprężarki, ze spalaniem sekwencyjnym oraz z kondensacyjną turbiną parogazową (KTPG).
EN
Different energy systems in a dual-fuel arrangement (these natural gas and lignite in different amounts) are presented in the paper. In those systems an OFz-425 boiler with a circulating fluidised bed is coupled with different types of gas turbines - working in a simple cycle, with and without compressor intersection cooling, with sequential combustion and with a steam-gas condensing turbine (SGCT).
16
Content available remote High-efficient gas turbine in industrial applications
EN
High fuel efficiency of a gas turbine that utilises heat from external sources (the so called external recuperation) provides advantageous economic and environmental conditions for electricity generation combined with industrial processes. An influence of external recuperation on efficiency and power of a gas turbine set, as well as compressor cooling have been analysed on the basis of examples of several gas turbines produced by well-known manufactures.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.