Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 12

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Highly effective methods of biological and chemical wastewater treatment applied in Poland resulted in an increased amount of generated sewage sludge, which pose serious problem related to its utilization. The purpose of this studies was to determine the impact of the thermal disintegration process (in low temperatures < 100°C) on the biodegradation of excess sludge, and then on the methane fermentation process. It was found that the method of thermal disintegration under the aforementioned conditions allows to achieve a very high degree of the excess sludge disintegration (> 70%) already at a temperature of 45°C. At the same time, the concentration of volatile fatty acids (VFAs) increases more than 55 times, which can significantly shorten the fermentation process.
2
Content available Verification of Baffle Factor for Straight Pipe Flow
EN
The baffle factor is a parameter widely used to describe flow system characteristics. This indicator is very important in designing disinfection devices. For example, it is used to convert the plug flowtime to the actual fluid residence time in the flowsystem of interest. Its accurate determination is a complex problem requiring tracer experiments or computational fluid dynamics simulations. Therefore, in practice, it is often taken from tables provided in the literature. The literature sources, however, state that the baffle factor for a flow in a straight pipe is equal to unity, which implies the identity between the pipe flow model and the plug flow model. This assumption is doubtful. The aim of the present work is to verify the baffle factor values assumed for the pipe flow. The merit of this study is the analytical derivation of the expression describing the baffle factor value with respect to flow characteristics. To this purpose, the analytical solution of a one-dimensional advection-diffusion equation with a Heaviside initial condition was used. It was demonstrated that the aforementioned assumption is wrong, as the baffle factor for a straight pipe is significantly less than unity.
EN
In recent years, the municipal WWTP operated by PEWIK Gdynia receives increasing quantity of industrial wastewater with COD/BOD ratio above 2. In most cases, it is probably due to the required reduction of certain pollutants before delivery of industrial wastewater to the sewage system. Implemented pre-treatment of industrial wastewater by on-site plants usually remove the nutrients and easily biodegradable organic matter, while other organic fractions are directed to the municipal WWTP. In this study the influence of industrial wastewater on the efficiency of technological processes was analyzed on the basis of WWTP in Gdynia-Debogorze. For this reason, the COD fractions (readily (soluble) and slowly (particulate) biodegradable fraction, and non-biodegradable soluble (inert) and particulate fraction) were analyzed in raw wastewater. Obtained results were discussed in terms of the efficiency of treatment processes as well as the energy consumption and the operating costs of the plant.
EN
The aim of this study was to analyze all liquid by-products generated at two MSWPs, located in metropolitan and rural areas. Obtained data indicated that the technological wastewater from the sorting and composting units were characterized by a high load of organic matter as well as a high nitrogen and phosphorus concentration, in some cases even 20 times higher than values obtained in the landfill leachate. To the best of our knowledge, such comprehensive studies have not yet been conducted in Poland.
PL
Praca przedstawia wyniki badań dezynfekcji biologicznie oczyszczonych ścieków z Grupowej Oczyszczalni Ścieków „Dębogórze" w Gdyni. Badania przeprowadzono z wykorzystaniem trzech technologii dezynfekcji: ozonowania, promieniowania UV oraz mikrofiltracji. Wszystkie z metod wykazały sięwysoką skuteczność dezynfekcji ścieków. O konkretnym wyborze powinny decydować względy ekonomiczne. Podkreślono jednocześnie rolę badań kontrolnych, wśród których za optymalne należy uznać badania z wykorzystaniem mikroskopu epifluorescencyjnego.
EN
Paper presents the results fo disinfection of biological treated wastewater from WWTP “Dębogórze” In Gdynia. The investigation was carried on with three disinfection technologies: ozonation, UV radiation and microfiltration. Each method appeared of high efficiency of wastewater disinfection. In such case the economical aspects should determine the choice of the method of disinfection. It appeared that the control studies are of great importance in assessment of disinfection efficiency. The method based on epifluorescentic microscopy should be recognized as optimal.
PL
Wyniki badań dezynfekcji biologicznie oczyszczonych ścieków z oczyszczalni „Wschód w Gdańsku. Badania z wykorzystaniem trzech technologii dezynfekcji: ozonowania, promieniowania UV oraz mikrofiltracji. Rola badań kontrolnych.
EN
The results of the investigation on disinfection of biologically treated wastewater from WWTP „Wschód” in Gdańsk. The studies with using of the three technologies of disinfection: ozonation, UV radiation and microfiltration. The significance of disinfection efficiency valuation.
PL
W pracy omówiono problematykę zagrożeń mikrobiologicznych, w tym nasilające się zjawisko lekooporności bakterii występujących w odpływach z oczyszczalni. Zwrócono uwagę na konieczność dezynfekcji i przedstawiono najczęściej stosowane metody dezynfekcji odpływów. Na tle wyników badań własnych nad zjawiskiem lekooporności bakterii związanym z dezynfekcją odpływów z oczyszczalni ścieków wskazano na potrzebę właściwego doboru metody dezynfekcji, która powinna być dostosowana do celu ich dalszego wykorzystania.
EN
In the paper the problem of microbiological hazards, including the phenomenon of increasing drug resistance of bacteria present in the outflows from wastewater treatment plants was discussed. Additionally the need for disinfection was highlighted and the most often used methods of treated wastewater disinfection was presented. The phenomenon of drug resistance of bacteria associated with wastewater treatment and disinfection indicate the need for proper selection of disinfection methods is crucial. Thus disinfection should be adapted to the purpose of further usage of treated wastewater.
PL
W pracy omówiono problematykę zagrożeń mikrobiologicznych, w tym nasilające się zjawisko lekooporności bakterii występują-cych w odpływach z oczyszczalni. Zwrócono uwagę na konieczność dezynfekcji i przedstawiono najczęściej stosowane metody dezynfekcji odpływów. Na tle wyników badań własnych nad zjawiskiem lekooporności bakterii związanym z dezynfekcją odpływów z oczyszczalni ścieków wskazano na potrzebę właściwego doboru metody dezynfekcji, która powinna być dostosowana do celu ich dalszego wykorzystania.
EN
In the paper the problem of microbiological hazards, including the phenomenon of increasing drug resistance of bacteria present in the outflows from wastewater treatment plants was discussed. Additionally the need for disinfection was highlighted and the most often used methods of treated wastewater disinfection was presented. The phenomenon of drug resistance of bacteria associated with wastewater treatment and disinfection indicate the need for proper selection of disinfection methods is crucial. Thus disinfection should be adapted to the purpose of further usage of treated wastewater.
9
Content available remote Wybrane zagrożenia środowiska i metody zapobiegania
PL
Zagrożenie środowiska ze strony ścieków komunalnych i odcieków składowiskowych. Zjawisko lekooporności bakterii występujących w środowisku wodnym. Dezynfekcja ścieków oczyszczonych biologicznie - promieniowanie UV, ultrafiltracja, ozonowanie. Współoczyszczanie ścieków komunalnych i odcieków składowiskowych.
EN
Threats of the environment from municipal wastewater and sanitary landfill leachates. Antibiotic resistance of bacteria existing in surface water. Disinfection of biologically treated wastewater by UV radiation, ultra leakage, ozonation. Co-treatment of municipal wastewater and salinity landfill leachates.
PL
Dystrybucja metali ciężkich w gruntach rekultywowanych osadem ściekowym. Wpływ składu granulometrycznego gruntu na migrację metali ciężkich.
EN
Distribution of heavy metals in soils reclaimed by sewage deposits. Influence of grain size distribution of soils on migration of heavy metals.
PL
Skuteczność rekultywacji dwóch obszarów zdegradowanych technicznie: składowisko odpadów paleniskowych oraz wyrobisko pożwirowe w woj. pomorskim. Biokumulacja metali ciężkich w biomasie roślinnej porastającej badane obiekty.
EN
Effectiveness of reclamation process of two degraded areas: power plant wastes storage yard and post-gravel excavation in Pomeranian region. Bioaccumulation of heavy metals in plant biomass growing analysed structures.
EN
Constructed wetlands (CW) have been considered as a waste and a stormwater treatment systems for small communities or for areas with unsteady sewage flow conditions. Several investigations were undertaken for estimation suspended solids, organic matter and nutrients efficiency removal but only few focused on retention of microorganisms in constructed wetlands. In this review mechanisms of elimination of viruses, indicator bacteria as well as helminth eggs and protozoan parasites are discussed. Generally the retention and the removal efficiency of microorganisms in the wetlands systems can be attributed to the combination of filtration, sorption and inactivation, which are controlled by the retention time and the flow condition. Filtration depends on the beds' matrix and involves the physical blocking of movement through the pores smaller than microorganisms. Binding between the solid surfaces and the microorganisms (especially bacteria cells) is mainly affected by the chemistry of the bed particles and the properties of the microbial organisms. The rate of microorganisms inactivation is probably also influenced by abiotic and biotic factors. The majority of allochtonic microorganisms die off after introduction to the "natural" treatment systems such as wetlands because of the abiotic stress. But even subpopulations better suited for survival and colonization, can also be eliminated because of predation. The bacterial phages, protozoa and nematodes as well as inhibitory substances secreted by other bacteria may also be a reason of reduction of the enteric bacteria in the wetland conditions. Also macrophytes in the wetland system are regarded as an essential in hygienisation of wastewater. However bacterial elimination in constructed wetlands is regarded as a highly efficient (> 99.9%), the final number of bacteria in the treated sewage can still affect the environmental ecosystems.
PL
Hydrofitowa metoda jest stosowana do oczyszczania wód opadowych, ścieków bytowo-gospodarczych z pojedynczych gospodarstw oraz odcieków ze składowisk komunalnych. Większość publikowanych wyników badań dotyczących skuteczności oczyszczania ścieków na złożach gruntowo-roślinnych koncentruje się głównie na zagadnieniach usuwania zawiesiny, substancji organicznych i pierwiastków biogennych, natomiast nieliczne tylko prace prezentują wyniki stanu sanitarnego odpływów. W pracy scharakteryzowano zasadnicze mechanizmy przyczyniające się do usuwania zanieczyszczeń mikrobiologicznych ze ścieków oczyszczanych w różnych konfiguracjach systemów hydrofitowych oraz przedstawiono ich efektywność w eliminacji bakterii wskaźnikowych. Obniżanie liczby bakterii pochodzenia kałowego, cyst pierwotniaków i jaj helmintów w procesach oczyszczania ścieków na filtrach gruntowo-roślinnych jest efektem ich zatrzymywania, eliminacji oraz obumierania. Zatrzymywanie tego typu allochtonicznych zanieczyszczeń w ośrodku porowatym jest efektem fizykochemicznych procesów, takich jak: sedymentacja, filtracja i adsorpcja, na które wpływają warunki przepływu i czas zatrzymania. Do obniżania liczby mikroorganizmów (eliminacji) przyczyniają się biologiczne procesy, wśród których do najważniejszych należą: drapieżnictwo, antagonizm, konkurencja o substancje pokarmowe lub pierwiastki śladowe i liza przy udziale bakterii lub wirusów. Obumieranie jest natomiast skutkiem niekorzystnego wpływu różnorodnych czynników abiotycznych, takich jak: odczyn (pH), temperatura, działanie promieniowania UV, brak wilgoci. Ponadto istotną rolę w usuwaniu zanieczyszczeń mikrobiologicznych odgrywają makrofity porastające systemy hydrofitowe, których skuteczność jest w znacznym stopniu związana z porą roku. Makrofity zmniejszają przepływ ścieków i sprzyjają sedymentacji drobnych cząstek zawiesiny wraz z zatrzymanymi na nich bakteriami. Również liczne substancje produkowane przez ich system korzeniowy względnie produkowane przez populacje bakterii zasiedlające korzenie są toksyczne dla bakterii pochodzenia kałowego. Z drugiej zaś strony makrofity chronią mikroorganizmy przed szkodliwym wpływem promieniowania UV. Wprawdzie skuteczność usuwania bakterii wskaźnikowych na filtrach gruntowo-roślinnych jest zbliżona do uzyskiwanej w wysoko efektywnych oczyszczalniach ścieków, to jednak odpływy z obu typów oczyszczalni nadal budzą zastrzeżenia pod względem mikrobiologicznym.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.