Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Synthesis of a new stationary phase for SPME based on polyaniline has been developed and optimized. The obtained stationary phase is designed for analysis of triphenylarsine (TPA) which is a marker of chemical warfare agents dumped in the Baltic Sea. The best TPA sorption properties were observed for fiber obtained during the electropolymerization of aniline from 0.1 M solution in 1.25 M H2SO4. Three cycles of scanning were performed in the range from –0.2 to 1.1 V, followed by 14 cycles in the range from 0.4 to 1.1 V, at a scanning speed of 20 mV/s. These conditions guarantee accurate, leveled and repeatable coating of the fiber with the polymer stationary phase. The maximum working temperature of the resulting SPME fiber was 220°C. It exhibited approximately 40% higher TPA extraction efficiency than the best available commercial fiber: DVB/CAR/PDMS. The highest TPA extraction efficiency was obtained at 60°C and after 90 min sorption. The limits of detection and quantification for the developed TPA analysis method were respectively 0.1 and 0.5 ppb. The precision of the method for five consecutive measurements was 4.7% for the same fiber and 7.2% for the five commercial fibers. Compared to standard liquid-solid extraction, the HS-SPME technique developed based on polyaniline-coated fiber remains competitive as simple, quick and low-cost.
PL
W pracy zaprojektowano i zoptymalizowano warunki syntezy nowej fazy stacjonarnej do SPME na bazie polianiliny, przeznaczonej do analizy trójfenyloarsyny (TPA), która jest markerem broni chemicznej zatopionej w Bałtyku. Najlepsze właściwości adsorpcyjne względem TPA uzyskano z użyciem włókna otrzymanego podczas elektropolimeryzacji aniliny (PANI) z jej 0,1M roztworu w 1,25M H2SO4. Skanowanie prowadzono w przedziale od –0,2 V do 1,1 V przez trzy cykle, a następnie w zakresie od 0,4 V do 1,1 V przez 14 cykli, z prędkością skanowania 20 mV/s. Warunki te zapewniły uzyskanie dokładnego, równomiernego i powtarzalnego pokrycia nośnika warstwą polimerową fazy stacjonarnej. Maksymalna temperatura pracy tak uzyskanego włókna wynosiła 220°C. Stwierdzono, że otrzymane w ten sposób włókno do SPME miało około 40% większą sprawność ekstrakcji TPA w porównaniu do najlepszego dostępnego włókna handlowego DVB/CAR/PDMS. Największą wydajność ekstrakcji TPA uzyskano w temperaturze 60°C i czasie 90 min. Granice oznaczalności i wykrywalności opracowanej metody analizy TPA z wykorzystaniem włókna PANI wynosiły odpowiednio 0,1 ppb i 0,5 ppb, a precyzja metody w przypadku pięciu kolejnych pomiarów wynosiła 4,7% dla tego samego włókna i 7,2% dla pięciu włókien komercyjnych. W porównaniu do tradycyjnej ekstrakcji typu ciało stałe-ciecz, opracowana technika HS-SPME z wykorzystaniem włókna pokrytego polianiliną zyskuje przewagę dzięki swojej prostocie, szybkości oraz niskim kosztom.
2
EN
The key objective of no-reference (NR) visual metrics is to predict the end-user experience concerning remotely delivered video content. Rapidly increasing demand for easily accessible, high quality video material makes it crucial for service providers to test the user experience without the need for comparison with reference material. Nevertheless, the QoE measurement is not enough. The information about the source or error is very important as well. Therefore, the described system is based on calculating numerous different NR indicators, which are combined to provide the overall quality score. In this paper, more quality indicators than are used in the QoE calculation are described, since some of them detect specific errors. Such specific errors are dificult to include in a global QoE model but are important from the operation point of view.
PL
Pomiar jakości w modelu bez referencji (ang. No-Reference, NR) ma na celu dostarczenie informacji na temat wrażeń użytkownika końcowego oglądającego testowaną sekwencje wizyjną. Badanie to odbywa się bez dostępu do materiału źródłowego i nie może opierać się na jakichkolwiek założeniach go dotyczących. Artykuł ten przedstawia pakiet oprogramowania składający się z 15 metryk wizyjnych stanowiących podstawę uniwersalnego systemu pomiarowego. Jako dodatek, opisane również zostały fundamentalne schematy optymalizacyjne oraz skrypty automatyzujące obliczenia.
EN
No-Reference (NR) quality measurements aim to provide information about end-user experience regarding given video content, without any access or assumptions about reference sequence. This reference material corresponds to uncompressed video or visual content as seen before transmission through the lossy environment. In this paper, we present software package consisting of 15 visual indicators being the foundation of versatile measurement system. In addition, basic optimization schemes and calulcation automation scripts are breifly described.
EN
Detection of explosives vapors is an extremely difficult task. The sensitivity of currently constructed detectors is often insufficient. The paper presents a description of an explosive vapors concentrator that improves the detection limit of some explosives detectors. These detector s have been developed at the Institute of Optoelectronics. The concentrator is especially dedicated to operate with nitrogen oxide detectors. Preliminary measurements show that using the concentrator, the recorded amount of nitrogen dioxide released from a 0.5 ng sample of TNT increases by a factor of approx. 20. In the concentrator an induction heater is applied. Thanks to this and because of the miniaturization of the container with an adsorbing material (approx. 1 cm3), an extremely high rate of tempera ture growth is achieved (up to 500°C within approx. 25 s). The concentration process is controlled by a microcontroller. Compact construction and battery power supply provide a possibility of using the concentrator as a portable device.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.