Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 45

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
The paper includes a summary of long-time research conducted by a research team in the Institute of Electrical Engineering and Computer Science at Silesian University of Technology. The research work has principally been related to selected problems in the field of analysis and synthesis of systems aimed at symmetrisation and improvement of some power quality parameters. This paper constitutes the second part of the report on the research. It has been devoted to three-phase system symmetrisation as well as effective elimination of higher harmonics and substantial improvement of power quality by means of hybrid active power filters.
EN
The paper includes a summary and a background of long-time research conducted by a research team in the Institute of Electrical Engineering and Computer Science at SilesianUniversity of Technology. The researchwork has principally been related to selected problems in the field of analysis and synthesis of systems aimed at symmetrisation and improvement of some power quality parameters. This paper constitutes a first part of the report on the research. It has been devoted to effective elimination of higher harmonics and reactive power compensation by means of parallel active power filters. The other problem discussed in this paper is related to this issue and it is very important from the economic point of view; it addresses optimal sizing and placement of active power filters in investigated power networks.
EN
Problems concerning electrical power quality and especially estimation of costs required for reduction of higher harmonics in power network voltage and current time waveforms have been considered in the paper. The application of active power filters to reduction of higher harmonics has been analysed taking into account, in particular, the necessary investment costs. Two goal functions have been used to solve the underlying optimization problem - the first one that enables direct cost minimization and the second one based on the cost-effectiveness approach used by economists. Such approach is substantially different from solutions proposed by other authors who concentrate rather on theoretical issues and do not take into consideration the economical market-based reality. In the paper, theoretical analysis has been followed by an example of optimal allocation of active power filters in a large supply system.
PL
W artykule przedstawione zostały zagadnienia związane z parametrami, określające jakość energii elektrycznej, a w szczególności metody eliminacji wyższych harmonicznych z przebiegów napięć i prądów zasilających. Autorzy przedstawili wyniki prac dotyczących głównie hybrydowych energetycznych filtrów aktywnych, metod sterowania oraz wyniki badań związane ze stabilnością i wrażliwością tych urządzeń. Zagadnienia teoretyczne zostały uzupełnione wynikami symulacji oraz badań laboratoryjnych.
EN
Problems of power quality, including methods of elimination of higher harmonics in power system voltage and current waveforms, have been considered in the paper. Authors have presented results of research related mainly to hybrid active power filters, control methods, stability and sensitivity of these devices. Theoretical results are complemented by simulations and laboratory tests.
PL
W artykule przedstawione zostały zagadnienia związane z parametrami, określające jakość energii elektrycznej, a w szczególności metody eliminacji wyższych harmonicznych z przebiegów napięć i prądów zasilających. Autorzy przedstawili wyniki prac dotyczących energetycznych filtrów aktywnych, metody sterowania oraz wyniki badań związane z poprawą dynamiki działania tych urządzeń. Zagadnienia teoretyczne zostały uzupełnione wynikami symulacji oraz badań laboratoryjnych.
EN
Problems of power quality, including methods of elimination of higher harmonics in power system voltage and current waveforms, have been considered in the paper. Authors have presented results of research related to active power filters, control methods and methods used to improve a dynamical behaviour of these devices. Theoretical results are complemented by simulations and laboratory tests.
PL
W artykule przedstawiono zagadnienia związane z parametrami, które określają jakość energii elektrycznej, a w szczególności metody eliminacji wyższych harmonicznych z przebiegów napięć i prądów zasilających. Autorzy przedstawili w nim metody modelowania oraz optymalnego doboru i rozmieszczenia energetycznych filtrów aktywnych w sieci zasilającej. Zagadnienia teoretyczne zostały uzupełnione wynikami symulacji.
EN
Problems of power quality, including methods of elimination of higher harmonics in power system voltage and current waveforms, have been considered in the paper. Authors have presented methods of active power filter modeling as well as theirs optimal sizing and allocation in power systems. Theoretical considerations have been followed by simulation results
7
Content available remote Porównanie algorytmów sterowania energetycznymi filtrami aktywnymi
PL
Jedna z metod eliminacji wyższych harmonicznych, kompensacji mocy biernej składowej podstawowej lub symetryzacji obciążenia polega na zastosowaniu energetycznych filtrów aktywnych (EFA). EFA dołączone do systemu zasilania w zależności od konfiguracji i sposobu sterowania mogą eliminować wszystkie lub wybrane niekorzystne składowe. Wymagają w tym celu odpowiedniego algorytmu sterowania dostosowanego do typu EFA oraz sieci zasilającej, do której został on podłączony. Podstawowym zadaniem takiego algorytmu jest wyznaczenie wzorcowych prądów kompensujących, które następnie zostaną wprowadzone do sieci zasilającej.
EN
Application of active power filter (APF) is one of the methods for higher harmonic reduction, reactive power compensation or symmetrization in three-phase systems. APF connected to power system, depending on control strategy and configuration, can fulfil all of these functions or only selected ones. Active compensator requires different control algorithms depending on its connection and type of network where it operates. The basic goal of control algorithms is to determine correctly reference compensation currents which are introduced into supply network.
EN
The paper deals with cost effective compensator placement and sizing. It becomes one of the most important problems in contemporary electrical networks, in which voltage and current waveform distortions increase year-by-year reaching or even exceeding limit values. The suppression of distortions could be carried out by means of three types of compensators, i.e., passive filters, active power filters and hybrid filters. So far, passive filters have been more popular mainly because of economic reasons, but active and hybrid filters have some advantages which should cause their wider application in the near future. Active power filter placement and sizing could be regarded as an optimization problem. A few objective functions have been proposed for this problem. In this paper we compare solutions obtained by means of combinatorial and genetic approaches. The theoretical discussion is followed by examples of active power filter placement and sizing.
PL
W artykule przedstawiono podstawowe typy silników z magnesami trwałymi stosowane w napędach elektrycznych. Omówiono budowę wirników, różnice konstrukcyjne oraz wskazano podstawowe wady i zalety silników synchronicznych z magnesami trwałymi (PMSM) oraz silników bezszczotkowych prądu stałego (BLDC). W dalszej części artykułu przedstawiono wyniki badań układu napędowego z silnikiem synchronicznym z magnesami trwałymi (wirnik IPM) oraz wirnikiem BLDC, który zasilany był z falowników z zaimplementowanymi różnymi algorytmami sterowania tj. BLDC, PMSM SPM, PMSM IPM.
EN
In the paper was a described basic type of permanent magnet motors used in electric drives. Rotors construction differences and points the basic advantages and disadvantages of permanent magnets synchronous motors (PMSM) and brushless DC motors (BLDC) was described. In the rest of the article results of tests the drive system of synchronous motor with permanent magnet (IPM rotor) and a BLDC rotor was presented. Drive system was powered by the inverter with implemented different control algorithms ie the BLDC, PMSM SPM, PMSM IPM.
EN
The significant problem of compensator placement and sizing in electrical networks has been analyzed in the paper. The compensation is usually realized by means of passive or active power filters. The former solution is widely used mainly because of the economical reasons, but the latter one becomes more and more popular as the number of nonlinear loads increases. Regardless of the compensator type the most important goal consists in voltage and current distortion drop below levels imposed by standards. Nevertheless, the desired effects should be achieved with the minimum cost. So far a few objective functions have been proposed for this optimization problem. It is claimed that minimization of the compensator currents leads also to the minimum costs. This paper shows that such simplified approach could lead to suboptimal solutions and in fact a function g(·) reflecting the relation between the compensator size and its price must be incorporated into objective functions. Moreover, in this case it is very easy to compare solutions obtained using compensators offered by different suppliers - it is enough to change the function g(·). Theoretical considerations have been illustrated by an example of active power filter allocation and sizing.
EN
In this paper the realization of digital parametric filter using digital signal processor TMS320C6416 manufactured by Texas Instruments has been described. The proposed system enables the signals filtration using low-pass filter with variable cut-off frequency. This filter enable passing or reducing the harmonic of input signal in accordance with assumed parametric function.
PL
W artykule opisano realizację cyfrowego filtru parametrycznego z wykorzystaniem procesora sygnałowego firmy Texas Instruments TMS320C6416. Zaproponowany układ umożliwia filtrację sygnałów filtrem dolnoprzepustowym o zmiennej częstotliwości granicznej przepuszczając lub tłumiąc harmoniczne sygnału wejściowego zgodnie z zadaną funkcją parametryzującą.
PL
Zaprezentowano przykład wykorzystania teorii mocy Fryzego do wyznaczenia wzorcowych prądów kompensujących energetycznego filtru aktywnego.
EN
The paper presents an example of using Fryze's theory of power to determine standard compensating currents of electric power active filter.
PL
W artykule przedstawione zostały zagadnienia związane z jakością energii elektrycznej, a w szczególności metodami eliminacji wyższych harmonicznych z przebiegów napięć i prądów zasilających. Najczęściej do tego celu wykorzystywane są pasywne filtry rezonansowe. Wadą takich układów jest duży wpływ impedancji sieci na wynik filtracji, a także niekorzystne zjawiska rezonansowe, które mogą wystąpić pomiędzy filtrem a siecią lub obciążeniem. Znacznie lepsze efekty filtracji, przy eliminacji wyżej wymienionych wad, można osiągnąć przy wykorzystaniu energetycznych filtrów aktywnych. Przykładowo równoległy energetyczny filtr aktywny jest energoelektronicznym źródłem prądu dodawczego, a w wyniku jego podłączenia prąd źródła osiąga kształt optymalny (sinusoidalny). W artykule przedstawiono propozycję komputerowej analizy rozpływu harmonicznych, która zostanie wykorzystana do optymalizacji rozmieszczenia energetycznych filtrów aktywnych w modelach sieci zasilającej.
EN
The paper presents some of the electric power quality issues. In particular, the methods of elimination of voltage and current high harmonics has been presented. The most popular method of reducing harmonic current distortions consists in using passive harmonic filters. Disadvantages of these filters are: the influence of line impedance on filtering results and the resonance between the filter and the impedance of a power system or the load. Better results can be achieved using the Active Power Filters (APF). For example, the shunt APF injects currents into the power system to compensate existing distortions, what causes the optimal (sinusoidal) supply currents. The paper describes a proposition of computer analysis method of the high harmonics propagation. This method will be used to optimize placement of active power filters in selected power system models.
PL
W artykule przedstawiono model częstotliwościowy energetycznego filtru aktywnego i przeprowadzono jego badania symulacyjne w wybranym układzie testowym dla algorytmu sterującego opartego na teorii dq, korzystając ze środowiska Matlab/Simulink. W efekcie określono skuteczność kompensacji poszczególnych harmo-nicznych prądu w zależności od częstotliwości pracy falownika oraz mocy odbiornika.
EN
A frequency model of an active power filter as well as its simulation investigation in Matlab/Simulink for dq control algorithm and a sample test system have been developed in the paper. As a result the quality of current compensation for selected harmonics as a function of switching frequency and load power has been determined.
15
Content available remote Analiza rozpływu harmonicznych w układzie z energetycznym filtrem aktywnym
PL
W artykule przedstawiono model częstotliwościowy energetycznego filtru aktywnego i przeprowadzono jego badania symulacyjne dla algorytmu sterującego opartego na teorii dq, korzystając ze środowiska Matlab/Simulink. W efekcie określono jakość kompensacji poszczególnych harmonicznych prądu w zależności od częstotliwości pracy falownika oraz mocy odbiornika.
EN
A frequency model of an active power filter as well as its simulation investigation in Matlab/Simulink for dq control algorithm are presented in the paper. As a result, the quality of current compensation for selected harmonics as a function of the switching frequency and load power has been determined.
EN
In the paper describes the problem of distortions in the encoder circuit of variable speed drive with PMSM motor. The impact of distortions in encoder circuit on operation of drive system with PMSM motor is analyzed. To analyze the impact of distortions used two incremental encoders with different constructions and different principles of operation were used. The first is an optical encoder with uses specially designed disk and optical transmitter and receiver. The second one uses a patented technology of capacity changes detection by high-frequency reference signal. To eliminate some of the distortions in the two encoders used capacitive filters in the supply system, and implemented additional systems forming encoder,s output waveforms. Use of the two systems together can contribute to significant reductions in distortions and thus the elimination of erroneous interpretation of the location of the shaft by the motor control algorithm.
17
Content available remote Predykcja w układach sterowania energetycznych filtrów aktywnych
PL
W artykule przedstawiono przykładowy algorytm sterowania Energetycznym Filtrem Aktywnym z predykcyjnym regulatorem prądu. Algorytm ten bazuje na dyskretnym modelu układu z wykorzystaniem estymatora napięcia lub obserwatora napięcia. W artykule przedstawiono rownież ogólne porownanie uładów sterowania z predykcją i bez predykcji. Analizy teoretyczne uzupełnione zostały wynikami symulacji.
EN
In the paper the control system of Active Power Filter with model based predictive current control has been presented. The estimator and phase voltage observer has been designed and implemented into control system. The properties of controller with and without prediction has been compared. Theoretical analysis has been followed by results of simulations.
PL
W artykule przedstawiono metody wykorzystania pakietu Matlab/Simulink do wyznaczania rozpływu harmonicznych we fragmencie systemu elektroenergetycznego. Dwie z nich bazują na wykorzystaniu dostępnych przyborników Matlaba (SimPowerSystems i PSAT), trzecia natomiast na bezpośredniej implementacji częstotliwościowego modelu systemu w języku Matlab. Dla wszystkich przedstawionych metod jest możliwe zastosowanie metod optymalizacyjnych (Optimization Toolbox) do optymalnego rozmieszczenia kompensatorów harmonicznych w analizowanym systemie.
EN
The paper presents three methods of Matlab/Simulink application to harmonic current flow simulation in selected fragments of an electrical power grid. The first two methods are based on SimPowerSystems and PSAT toolboxes. The third one involves direct implementation of the system frequency model in Matlab language. For the all presented methods it is possible to use Optimization Toolbox algorithms to find the optimal placement of harmonic compensators in the analysed system.
19
Content available remote Wykorzystanie sieci neuronowej do poprawy dynamiki wyznaczania składowej stałej
PL
W artykule przedstawiono zastosowanie sieci neuronowych do rozwiązania problemu z zakresu filtracji sygnałów. Problem ten polegał na wyznaczeniu składowej stałej w możliwie jak najkrótszym czasie. Opisano sposób postępowania podczas projektowania oraz optymalizacji sieci neuronowej. Zaprojektowana sieć została zrealizowana fizycznie z wykorzystaniem procesora sygnałowego.
EN
This paper presents application of neural networks to solution of signal filtration problem. It consists in constant component extraction during as short time period as possible. The paper describes how to deal with the design and optimization of a neural network which is able to solve the given task. The implementation of this problem has been addressed for the use of computational signal processing capabilities of DSP processor.
20
Content available remote Systemy zdalnego monitoringu wybranych parametrów jakości energii elektrycznej
PL
Prezentowany artykuł jest wynikiem prac badawczych prowadzonych w Instytucie Elektrotechniki i Informatyki, dotyczących metod analizy i poprawy jakości energii elektrycznej. Przedstawiono w nim koncepcje oraz realizację układów do zdalnego monitoringu wybranych parametrów jakości energii.
EN
The presented paper is the result of research carried out at the Institute of Industrial Electrical Engineering and Informatics on the methods of analysis and improvement of power quality. There are described concepts and implementation of systems for remote monitoring of selected power quality parameters.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.