Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Corticosteroids are anti-inflammatory and immunosuppressant drugs. Topical corticosteroids formulations (ointments, creams, gels) are used in the treatment of different types of dermatitis and urticaria. Considering their therapeutic and whitening effects, they are frequently used for counterfeiting of cosmetic products. Corticosteroids can cause different local and systemic side effects. HPLC method is often chosen for their analysis, because it is selective, sensitive, precise, simple and fast. The aim of this study was optimization and validation of RP-HPLC method with UV detection for determination of trace levels of corticosteroids in ambiphilic creams. This method is used for qualitative and quantitative analysis of evaluated corticosteroids. Mometasone furoate, hydrocortisone acetate, fluocinonide, fluocinolone acetonide, betamethasone, betamethasone dipropionate and triamcinolone acetonide were evaluated. Separation was performed on Inertsil® ODS-3V 250 × 4.6 mm, 5 μm chromatographic column. Mobile phase was mixture of acetonitrile and water 50:50 (v/v) with gradient elution and flow rate 1 mL min⁻¹. Column temperature was held on 40 °C and UV detection was performed at 240 nm. Selectivity, linearity, accuracy, precision and limit of quantification (LOQ) were evaluated. Method is selective because ambiphilic cream base peaks and corticosteroids peaks were not overlapping. Linearity was confirmed since correlation coefficient was 1 for all compounds. Accuracy and precision were evaluated for hydrocortisone acetate and betamethasone dipropionate. Determined Recovery values were in range of 70–130%. Both RSD values (21.46% and 9.59%) were lower than 30%. Method is highly sensitive since LOQ concentrations were in ng mL⁻¹ range. All evaluated parameters of validation were in accordance with regulatory requirements. Validated RP-HPLC method can be used for qualitative and quantitative analysis of selected corticosteroids in ambiphilic creams.
EN
Ziprasidone is the second generation antipsychotic drug with unique multipotent G-protein-coupled (GPCR) receptor binding profile. Since ziprasidone is a highly lipophilic and unstable compound, development of efficient method for a concurrent assay of ziprasidone and its main impurities was a very challenging task. The UHPLC-MS/MS method that we developed for simultaneous determination of ziprasidone and its main impurities (BITP, Chloroethyl-chloroindolinone, Zip-oxide, Zip-dimer, and Zip-BIT) was compared with some other related HPLC-UV methods of our own and other authorship. An increase of the mobile phase pH value from 2.5 to 4.7 units in the examined analytical methods influenced elution order of the investigated compounds. It was found out that the UHPLC-MS/MS method is more selective and sensitive than the earlier developed HPLC-UV method. Similar to our earlier HPLC-UV method, the UHPLC-MS/MS method is linear with a correlation coefficient (r) above 0.99 for all the analysed compounds, but with a negligibly lower precision and accuracy. Finally, with shorter analysis time, smaller column size and reduction of solvent consumption, UHPLC-MS/MS is assumed as a greener method than HPLC-UV for the ziprasidone purity assay. After transfer of the UHPLC-MS/MS method to the UHPLC-DAD system, suitability of the UHPLC-DAD method for routine control of ziprasidone and its main impurities is examined and confirmed based on the retained good selectivity, resolution and short analysis time.
EN
Gentamicin sulfate is a potent broad spectrum aminoglycoside antibiotic which is used against Gram-positive and Gram-negative bacteria. A simple, isocratic HPLC method for separation, identification and determination of gentamicin and parabens (methylparaben and propylparaben) was developed and validated. To our knowledge there is no report about simultaneous determination of those three analytes in pharmaceutical products. The optimum chromatographic conditions were achieved on CN column with a mobile phase consisting of 0.15% triethylamine in 10 mM KH₂PO₄ aqueous solution (final pH 3.0 adjusted with H₃PO₄) and methanol in the ratio 70:30 (v/v), providing selective quantification of analytes within 5 min. The method was successfully validated according to ICH guidelines acceptance criteria in terms of selectivity, linearity, accuracy, precision and robustness. The linearity of the method was proved in defined concentrations ranges for gentamicin (0.32–1.04 mg mL⁻¹), methylparaben (0.0072–0.0234 mg mL⁻¹) and propylparaben (0.0008–0.0026 mg mL⁻¹). Relative standard deviations calculated for all analytes in precision testing were <2% (analysis repeatability) and <3% (intermediate precision). Recovery values were between 98.87% and 101.67%. Chromatographic parameters are not significantly influenced by small variations of column temperature, pH and molarity of KH₂PO₄. Finally, the method was successfully applied for quantitative determination of gentamicin and parabens in commercially available solution for injection. Proposed HPLC method is found to be promising in terms of simplicity, analysis times and non-use of derivatization and ion-pair agents.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.