Close-form expression for the Strehl ratio calculated in the spatial frequency domain of the optical transfer function (SOTF) is considered for the case of time-varying dynamic optical system that has circular symmetry. Specifically, closed-form expressions for the temporally averaged SOTF are considered, which can be easily evaluated numerically (what we call a semi-analytic solution). As for the case of a static wavefront, described in Part 1 of this work, it is shown that the proposed methods are computationally more efficient than the commonly used approach based on the discrete Fourier transform.
Close-form expression for the Strehl ratio calculated in the spatial frequency domain of the optical transfer function (SOTF) is considered for the case of an optical system that has circular symmetry. First, it is proved that the SOTF for the aberration-free diffraction limited optical system is equal to one. Further, a semi-analytic solution for the SOTF for a system described by the second (defocus) and the fourth (spherical) order aberrations is provided. It is shown that the proposed semi-analytical solution is of an order of a magnitude computationally more efficient than the commonly used approach based on the discrete Fourier transformation.
Celem niniejszej pracy było opracowanie nowej metodologii do celów pomiaru i analizy wymiany łez na powierzchni oka w oparciu o obserwację spadku natężenia fluorescencji filmu łzowego w czasie, a także opisanie zależności pomiędzy nowozdefiniowanym parametrem oczyszczania łez oraz innymi miarami charakteryzującymi film łzowy. Badania wykonano na grupie 40 młodych ochotników w wieku 32 ± 14 lat. Na protokół kliniczny składały się: historia medyczna uczestnika, kwestionariusz McMonniesa, szczegółowa ocena pod biomikroskopem z lampą szczelinową oraz pomiar parametru wymiany łez przy pomocy profilometru fluoresceinowego. Parametr wymiany łez cechuje duża zmienność osobnicza i wynosi on średnio 39 ± 23%. Zanotowano statystycznie znaczące korelacje pomiędzy parametrem wymiany łez a wynikiem kwestionariusza McMonniesa oraz czasem przerwania filmu łzowego mierzonym przy pomocy fluoresceiny. Profilometr fluoresceinowy pozwala na śledzenie dynamicznych zmian zachodzących w filmie łzowym na całej powierzchni oka i ma zastosowanie w jakościowej ocenie dynamiki łez.
EN
The aim of the study was to develop a new methodology for tear-film dynamics assessment by observing fluorescein decay rate over time and to understand the relationship between the newly defined tear fluorescein wash-out rate (TFWR) and other measures of tear film be-haviour. Forty subjects aged 32 ± 14 y.o. volunteered for the study. It consisted of the review of medical history, McMonnies questionnaire, slit lamp examination, and TFWR measurements using a newly-devel-oped fluorescein profilometry. TFWR is highly subject-dependent. The group mean TFWR was 39 ± 23% at 30-second mark after the beginning of measurements. Statistically significant correlations were found between the percentage TFWR and McMonnies questionnaire score, as well as fluorescein tear film break-up time. Fluorescein profilometry allows clinicians to follow dynamic changes occurring in the tear film on the entire ocular surface and may be used for qualitative assessment of the tear film dynamics.
Występowanie dykrotycznego kształtu sygnału pulsu rogówki oka jest powiązane z procesem starzenia się i występowaniem jaskry. Dotychczas procedura wykrywania dykrotyzmu wymagała równoległego synchronicznego pomiaru pulsu rogówki oka, sygnału EKG i sygnału pulsu krwi, jednak nowe badania mogą pozwolić na detekcję dykrotyzmu tylko za pomocą pomiaru sygnału pulsu rogówki. Dokładność wykrywania dykrotyzmu zależy od parametrów sygnału wejściowego: długości i częstotliwości próbkowania. Z powodu odruchu mrugania u niektórych pacjentów trudno jest uzyskać odpowiednio długi sygnał nieobejmujący odruchu mrugania. Przeprowadzono eksperymenty numeryczne w celu określenia minimalnych wymagań rejestracji sygnału wejściowego w celu uzyskania odpowiedniej jakości klasyfikacji. Rezultaty wskazują na możliwość uzyskania dostatecznej jakości klasyfikacji sygnałów krótszych od 10 sekund pod warunkiem zapewnienia odpowiedniej częstotliwości próbkowania.
EN
The presence of the ocular dicrotic pulse is associated with aging and the glaucoma incidence. Previous procedures for detecting ocular dicrotism required synchronous measurement of ECG and blood pulse signals. However, recent studies have offered an opportunity to detect ocular dicrotism from the corneal pulse signal alone. The accuracy of the detection procedure mainly depends on the input signal length and its sampling frequency. The acquisition of the corneal pulse signal is performed in suppress blinking conditions. Hence, it is often difficult to acquire a sufficiently long signal for the analysis. Numerical experiments were conducted to determine the minimum requirements of the input signal in order to obtain adequate classification rate. The results indicate the possibility of obtaining sufficient classification rates for signals shorter than 10 seconds provided an adequate sampling is maintained.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Coraz częściej spotykamy się z zespołem suchego oka wywołanym noszeniem soczewek kontaktowych. Możliwość doboru odpowiedniego materiału soczewki kontaktowej pod względem biokompatybilności z filmem łzowym danego użytkownika mogłaby znacznie zmniejszyć ryzyko występowania komplikacji związanych z nadmiernym parowaniem filmu łzowego z powierzchni soczewki. Za pomocą metody pomiarowej opartej na interferencji mamy możliwość nie tylko zmierzyć ilościowo stabilność filmu łzowego na oku / soczewce kontaktowej w warunkach in vivo, ale również odróżnić materiał soczewki i wskazać ten, który w najmniejszym stopniu wpływa na zmianę dynamiki filmu łzowego w stosunku do zachowania filmu łzowego na rogówce.
EN
Increasingly, eye care practitioners meet more contact lens induced dry eye cases in their practice. The possibility of choosing the appropriate contact lens material in terms of its biocompatibility with the tear film of a wearer could potentially reduce the risk of complications associated with excessive tear film evaporation from the surface of the lens. With the help of the measurement method based on interferometry, we are able not only to quantitatively measure the stability of the tear film on the eye / contact lens in vivo, but also to distinguish between the contact lens materials and indicate the one that least affects the tear film dynamics in relation to the behavior of the tear film observed on the cornea.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Większość optometrystów i okulistów nie jest dobrze zaznajomiona z pojęciami aberracji monochromatycznych i ma trudności z interpretacją własności wzrokowych oka na podstawie szeregu współczynników wielomianu Zernikego lub map aberracji frontu falowego. Z drugiej strony, są oni bardzo dobrze wyszkoleni w interpretacji mocy refrakcyjnej oka, głównie w przypadku mocy sferocylindrycznej, która określa aberracje niższego rzędu. Metody przedstawione w niniejszym artykule uogólniają koncepcję mocy refrakcyjnej oka do aberracji wyższych rzędów i przedstawiają je w postaci map refrakcyjnych wyrażanych w dioptriach. Taka reprezentacja aberracji monochromatycznych może być dla tych grup bardziej intuicyjna i zrozumiała.
EN
The majority of optometrists and ophthalmologists have difficulties interpreting monochromatic wavefront aberrations, particularly when expressed in terms of a set of Zernike polynomial coefficients or their graphic equivalents. On the other hand, they are very well trained in the interpretations of eye refractive power, particularly in the case of the spherocylindrical power that describes the aberrations of the lower order. The methods described in the paper generalise the concept of refractive power to higher order aberrations and present them in dioptric power maps. Such representation of monochromatic aberrations could prove to be more intuitive and comprehensible for those groups.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The characteristics of binocular axial eye movements are of interest in studies of eye biomechanics and vision. Current techniques that are used to evaluate such movements were found to be of insufficient resolution. Here, synchronised measurements of binocular eye movements with custom designed high resolution ultrasound transducers, and cardiac electric cycle were considered. The mechanical and electrical signals were examined using spectral, time-frequency, and coherence analyses. The results showed that a close correlation and intricate phase relationships exist between longitudinal eye movements and cardiopulmonary signals. Understanding these relationships could provide a better insight on interactions between eye biomechanics and vision.