Nuclear medicine techniques allow physicians to observe and diagnose physiology of chosen organs as well as the whole body of a patient. This visualization is possible not only because radioisotopes are applied, but there is also a significant progress in the computer software possibility. The advantage of the cooperation between medicine and informatics can be implemented in the radiation protection field of medical staff. The presented computer software, so-called Optimizer, was dedicated to the medical staff responsible for radiopharmaceutical preparation. It is known that the doses obtained in the nuclear medicine "hot labs" can be higher in comparison with the doses obtained by the rest of the personnel in the same department. The main advantage of the presented program is that the time needed for radiopharmaceutical preparation can be shortened and, as a result, the doses absorbed by personel can be reduced. The information of the volume containing planned radioactivity at the time of the application can significantly reduce the number of checking (volume and radioactivity), which normally takes place before the final handing over the radiopharmaceutical to the application. A user-friendly interface provides control at each step of the preparation protocol. For the convenience of medical staff all current examinations were coloured in one of the three colours : red (an application has to be done now), yellow (waiting) and green (done). The Optimizer was created for the Nuclear Medicine Department in the 5th Military Hospital in Kraków (Poland). What is more, currently it is successfully used and final TLD (thermoluminescent dosimetry) tests have been performed.
2
Content available remote Pomiar średniej wartości ciśnienia krwi czujnikiem pneumatycznym
PL
Przedstawiono koncepcję bezinwazyjnego pomiaru średniej wartości ciśnienia krwi za pomocą czujnika pneumatycznego oraz wykorzystanie tego pomiaru do samoczynnego wzorcowania przyrządu, przeznaczonego do określania i rejestracji fali tętna krwi. Przytoczono wyniki badań, przeprowadzonych na modelu fizycznym tętnicy oraz na pacjentach.
EN
A principle of non-invasive mean arterial pressure measurement by means of pneumatic sensor and application of this measurement for a self-calibration of device for an arterial blood pressure waveform measurement and recording are described. Results of laboratory investigation on artificial artery and on patients are given as well.
PL
W artykule przedstawiono współpracę komputera z pneumatycznym czujnikiem do bezinwazyjnego pomiaru fali tętna krwi, czyli przebiegu ciśnienia krwi w czasie. Cisnienie wyjściowe czujnika przetwarzane jest na sygnał cyfrowy, który po wstępnej filtracji w module zasilającym, przesłany zostaje za pomocą kabla USB do komputera. W komputerze sygnał ulega dalszemu przetworzeniu i analizie. Na ekranie komputera zostaje wyświetlona fala tętna wraz z podstawowymi parametrami.
EN
Cooperation between computer and pneumatic sensor for noninvasive blood pressure monitoring is described. Pressure sensor output is digitized and sent to computer over USB cable after initial filtration in power module. Signal undergoes in a computer for further processes and analysis. Screen displays blood pressure waveform and its basic parameters.
PL
Czujnik przeznaczony jest do bezinwazyjnego pomiaru fali tętna krwi. Jego poprawna praca zależy od prawidłowego doboru parametrów konstrukcyjnych wzmacniacza typu dysza-przysłona i ciśnienia zasilania. Dlatego stworzono i zweryikowano model czujnika, który wykorzystano do doboru jego parametrów. Jako kryterium poprawnej pracy czujnika przyjęto moduł charakterystyki częstotliwościowej dla wszystkich znaczących składowych harmonicznych typowego przebiegu ciśnienia krwi.
EN
The sensor is used to noninvasive arterial blood pressure wave measurement. Its correct operation depends on adequate choice of nozzle-lapper ampliier parammeters and supply pressure. For this reason sensor model has been developed and validated then used for calculating sensor parameters. Criterion of acurate measurment of blood pressure waveform was amplitude ratio of sensor frequency response for all frequencies contained in measured pressure wave with signifcant amplitude.
5
Content available remote Model matematyczny pneumatycznego czujnika niskich ciśnień
EN
Construction and principle of work of original pneumatic low pressure sensor is described and its numerical model is analysed. Some characteristics of the real device were compared with those computed with using "Matlab Simulink" software. Good accordance of model results with experimental data allows improving patient blood pressure measurements.
PL
W publikacji zaproponowano procedurę identyfikującą przegrzewacza pary kotła energetycznego metodą predykcji błędów (PEM) prxy działającym układzie regulacji. Sygnały pomiarowe w postaci ciągów c/asowych z kotła BP1150 zostały użyte do estymacji parametrów modelu procesu o strukturze wynikającej z analizy teoretycznej przegrzewacza pary (konstrukcja, własności fizyko-chemiczne medium) wg Profosa. Wyesty-mowanc modele dla trzech różnych obciążeń kotła porównano z modelami Profosa (odpowiedzi skokowe oraz wariancje sygnałów wyjściowych przy identycznych stochastycznych sygnałach wejściowych). Wynik badań symulacyjnych potwierdza dobrą skuteczność zastosowanej procedury identyfikacyjnej.
EN
In the paper the identification procedure of steam superheater in power boiler by the prediction errors method (PEM) at running automatic control system was presented. The measurement signals (time series) from the outlet of a boiler BP1150 were used for process estimation of model's parameters. The structure of model follows the theoretical analysis of superheater (the construction, physical and chemical medium prop- ertics) based on the Profos model. The estimated models for three different boiler's load were compared with Profos models (step responses and variances of output signals at identical stochastic input signals). The repsuits of simulation experiments confirm the good effectiveness of the identification procedure applied.
PL
W artykule podano algorytm sterowania upustami ciepłowniczymi turbin. Omówiono ładowanie i rozładowanie zasobników połączony w sposób szeregowo-równoległy oraz czujniki i urządzenia wykonawcze potrzebne do wykorzystania akumulacji ciepła w systemie ciepłowniczym. Zaproponowano ekran wizualizacji danych o zakumulowanym cieple.
EN
Control algorithm of CHP turbine's extraction for district heating purposes is given in the paper. Heat from turbine is supplied to water heat containers, which covers peak heat demand in district heating system. Loading and unloading of heat containers connected in parallel-series way was discussed, also sensors and actuators needed to properly use of heat containers. Data visualization screen is suggested.