EN
The quality of indoor air in educational institutions is a critical determinant of the health and well-being of students. The purpose of the study was indoor air quality monitoring carried out for different age groups of students in grades IV–VIII or college classrooms (students used the classroom according to the schedule, the same group uses the room for up to 2 classes), I–III (students stay in the classroom for all classes, leaving only during breaks), kindergarten “0” (students are practically in one and the same room all day). The individual measurements included measurement of CO2 concentration, concentration of PM2.5 and PM10 particles, formaldehyde, volatile organic compounds (VOCs), along with monitoring of changes in temperature and humidity in the classroom. The results indicate that children are exposed to elevated levels of these pollutants for a significant portion of their school day, which can have implications for their health and well-being. The findings reveal significant deviations from the recommended levels, emphasizing the need for improved ventilation and monitoring practices.
EN
The purpose of this study was to determine the amount of particulate and microbial contaminants, i.e. bacteria and fungi found in indoor air in a lecture hall in one of Lublin's universities and their classification. In the research part, the amount of particulate and microbial pollutants was measured. Bioaerosols were investigated using an Andersen cascade impactor, which was located in the central part of the room at a height of 1–1.5 m, and single-level impactors. Identification of the microorganisms present in indoor air was carried out. The air in the room was sampled before the start of class to determine the "background," i.e. the concentration level of microbial contaminants in the classroom without the presence of students. Subsequent measurements were taken during teaching activities in the presence of students and the teacher. The study shows that the air condition in the classroom during its operation met the requirements in terms of PM2.5, PM10 and microorganisms. The highest risk was recorded for carbon dioxide. Moreover, the highest recorded readings of this pollutant coincided with the maximum concentrations of the other monitored quantities. Therefore, it can be unequivocally stated that in the case of the analyzed room, monitoring carbon dioxide and adjusting the size of the ventilation airflow to maintain its concentration within the limit of 1000 ppm would guarantee the maintenance of adequate indoor air quality. The study showed no correlation between CO2 concentration and measured concentrations of microbial contaminants.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.