Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The study involved investigation of the relationship between the radon concentrations in the ground air – and thus in the indoor air – and the geological structure of the Lubelskie Voivodeship (eastern Poland). Both passive and active methods were used for measuring the radon concentrations in coal, phosphate and chalk mines, caves, wells as well as indoor environments. The study also included elemental, uranium and lead isotope analyses of rocks. The performed research showed that Paleogene and Mesozoic sedimentary rocks rich in radionuclides are the sources of radon in the Lubelskie Voivodeship. In the case of the buildings located in proximity to such rocks, characterized by relatively high radon exhalations, radon remediation methods are recommended. Already at the designing stage of buildings, the measures which protect against the hazardous radon gas should be applied.
EN
Radon concentration was measured in 11 thermal spas in Visegrad countries (Czech Republic, Hungary, Poland, and Slovakia). The results showed that in 84% of spas radon activity concentration is less than 400 Bq·m–3. However, areas with radon activity concentration exceeding 1000 Bq·m–3 were found in the Czech Republic and Slovakia as well. Preliminary analyses indicated that the highest radon activities in spas were found in places with thermal pools. Radon concentration in waters used in spas ranged from 0.5 Bq/l to 384 Bq/l. The influence of radon activity concentration in water on radon activity in the air inside the spa was observed. It was found to increase indoor radon with increasing radon in the waters. Correlation with indoor radon and radon in water was more significant for baths and less significant for pool waters. In the cases filling of the bath from water taps, significantly contribute to the increased radon was observed in the pool and bath areas of the spa.
EN
Six radon laboratories, which perform indoor radon measurements to jointly investigate temporal variations of radon concentration in houses in a couple of regions in Poland, participated in the intercomparison exercise. There are involved three commercially available Hungarian RadoSys systems and four own laboratory methods. All of them are based on the etched-track CR-39 detectors. The intercomparison was conducted in a calibration laboratory of the Central Laboratory for Radiological Protection (CLOR), Warsaw, Poland, accredited by the Polish Center for Accreditation (previously AP 101, at present AP 057). Comparison measurements were performed during three expositions in the CLOR’s radon calibration chamber under controlled normal climatic conditions and steady radon concentration. The results were referred to the value of the radon concentration determined by AlphaGUARD monitor traceable to the primary 222Rn standard in Physikalisch-Technische Bundesanstalt (PTB), Braunchweig, Germany. The mean performance ratio defined as a ratio of the reference to participant’s result range from 0.88 to 1.31.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.